  • Technique demonstrated: Scanning Nitrogen-Vacancy Magnetometry (SNVM) for ultrasensitive, quantitative characterization of nanoscale magnetic inhomogeneities in individual in-plane magnetized nanowires (NWs).
  • Target structures: CoFeB magnetic NWs fabricated on Si/SiO2 substrates, with thicknesses of 5 nm and 10 nm and lateral widths on the order of ~100 nm.
  • Key achievement: Detection of local variations in saturation magnetization (Ms) of the CoFeB NWs on the order of ≤30%, with nanoscale spatial resolution and µT magnetic field sensitivity.
  • Methodology highlights: Use of both iso-B and full-B SNVM imaging modes combined with First-Order Reversal Curve (FORC) analysis and micromagnetic simulations using a magnetostatic model (OOMMF).
  • Physical origin of contrast: Local inhomogeneities in the NWs (density, compositional, or strain-induced) that produce fluctuations in in-plane Ms; domain-wall-generated fields were ruled out via simulations, indicating continuous, defect-free wire regions in the studied area.
  • Significance: Establishes SNVM as a quantitative diagnostic for spintronic devices at aggressively scaled dimensions, beyond the reach of conventional magnetometry.
ParameterValueUnitContext
Magnetic NW materialCoFeB—In-plane magnetized, spintronic building block
NW thickness (sample a)5nmThinner CoFeB stack
NW thickness (sample b)10nmThicker CoFeB stack
NW lateral dimension~100nmLateral wire width shown in MFM/TEM
UnderlayerSiO2—Sub-surface oxide layer
SubstrateSi—Silicon wafer base
Diamond probe thickness12nmNV-center active depth inferred from calibration
NV diamond probe supplierQnami AG—Commercial SNVM tip (Quantilever MX)
Detection sensitivityµTµTMagnetic field sensitivity per NV measurement
Ms variation detected≤30%Local saturation magnetization fluctuation along the NW
Coercive field (Hc)~97mTExtracted from FORC distribution
Interaction field distribution0-150mTFORC-derived switching field distribution
Switching field distribution60-100mTOperating range for full-B imaging
AFM mode operationTapping—Simultaneous topography and magnetic imaging
Microwave driveGreen laser + MW—Standard ODMR excitation for NV spin readout
Simulation frameworkOOMMF (NIST)—Micromagnetic validation of SNVM contrast
  • NW fabrication: CoFeB thin films sputtered on Si/SiO2 substrates, patterned into NW arrays; TEM/SEM used to verify wire continuity and geometry.
  • SNVM imaging: NV-diamond scanning probe rastered over the NW array; magnetic fields encoded as Zeeman shifts of the NV electron spin resonance.
  • iso-B mode: Constant applied bias field; measures gradient/perturbation fields superimposed on a uniform background.
  • full-B mode: Full magnetic field reconstruction from frequency-shift maps; enables quantitative B-field extraction.
  • FORC analysis: First-Order Reversal Curves acquired to extract coercive field (Hc), switching field distribution, and interaction field distribution.
  • Calibration: Reference NV sample used to estimate the NV-center depth within the diamond tip (~12 nm).
  • Micromagnetic simulation: OOMMF-based magnetostatic model reproducing SNVM contrast; varied Ms and defect sizes to match experimental images.
  • Comparative validation: Symmetry of Cartesian field projections vs. asymmetry along the NV axis explains experimental field distribution.
  • Applicable Materials:

    • Optical/Quantum Grade SCD for SNVM probe diamond tips requiring stable, high-coherence NV centers. 6CCVD’s single-crystal diamond platform supports the sub-15 nm shallow NV regime demanded by this work, with controlled nitrogen incorporation for optimal T2.
    • Ultra-flat PCD membranes as alternative scanning probes where larger-area or array-format NV sensing is desired; surface roughness is held to Ra < 5 nm on inch-size wafers for low-topography cross-talk.
    • Electronic-grade SCD (isotopically engineered) if your next-generation SNVM targets longer coherence times (T2) for weaker stray-field detection beyond the µT threshold demonstrated here.
  • Customization Potential:

    • Diamond thickness control (0.1 µm-500 µm) allows precise tuning of the NV layer depth — the 12 nm active region reported in the paper can be replicated or further reduced for higher spatial resolution.
    • Wafer dimensions up to 125 mm (PCD) support batch fabrication of SNVM probe arrays for high-throughput wafer-scale magnetic imaging.
    • Custom metalization (Ti/Pt/Au, W, Cu) enables integration of diamond SNVM tips with coplanar microwave waveguides required for ODMR drive, and laser-cutting/dicing services permit miniaturization into Quantilever-style cantilever geometries.
    • Boron-Doped (BDD) diamond can be supplied if an integrated conductive path for electrically-addressable NV sensing is required in future device architectures.
  • Engineering Support:

    • 6CCVD’s in-house PhD team can assist with NV-diamond material selection for spintronic metrology, racetrack memory, and spin-wave device characterization — the exact application class addressed in this paper. We can co-define diamond grade, NV density, thickness, and metal stack to match your target spatial resolution (sub-50 nm) and magnetic field sensitivity (sub-µT).
  • Call to Action:

    • For custom specifications or material consultation, visit 6ccvd.com or contact our engineering team directly.
View Original Abstract

Magnetic nanowires (NWs) are essential building blocks of spintronics devices as they offer tunable magnetic properties and anisotropy through their geometry. While the synthesis and compositional control of NWs have seen major improvements, considerable challenges remain for the characterization of local magnetic features at the nanoscale. Here, we demonstrate nonperturbative field distribution mapping in ultrascaled magnetic nanowires with diameters down to 6 nm by scanning nitrogen-vacancy magnetometry. This enables localized, minimally invasive magnetic imaging with sensitivity down to 3 μT Hz<sup>-1/2</sup>. The imaging reveals the presence of weak magnetic inhomogeneities inside in-plane magnetized nanowires that are largely undetectable with standard metrology and can be related to local fluctuations of the NWs’ saturation magnetization. In addition, the strong magnetic field confinement in the nanowires allows for the study of the interaction between the stray magnetic field and the nitrogen-vacancy sensor, thus clarifying the contrasting formation mechanisms for technologically relevant magnetic nanostructures.