Radiation tolerance of diamond detectors
At a Glance
Section titled “At a Glance”| Metadata | Details |
|---|---|
| Publication Date | 2022-11-01 |
| Journal | Journal of Physics Conference Series |
| Authors | L. Bäni, M. Artuso, F. Bachmair, M. Bartosik, H. P. Beck |
| Institutions | Istituto Nazionale di Fisica Nucleare, Sezione di Lecce, University of Bonn |
| Citations | 6 |
| Analysis | Full AI Review Included |
Executive Summary
Section titled “Executive Summary”- Core Material Challenge: The RD42 Collaboration addresses the need for radiation-hard detector materials for next-generation high-energy physics experiments (e.g., HL-LHC), where innermost detector layers will face extreme particle fluences.
- Material Validation: Chemical Vapor Deposition (CVD) diamond is validated as a superior detector material due to its high displacement energy (~42 eV/atom), outperforming silicon in extreme radiation environments.
- Radiation Tolerance Data: The study characterizes the radiation tolerance of both single-crystalline (scCVD) and poly-crystalline (pCVD) diamond against protons (24 GeV, 70 MeV, 800 MeV), pions (24 GeV), and neutrons.
- Performance Milestone: At a fluence of 3.5 × 1015 p/cm2 (800 MeV protons), a planar pCVD diamond detector exhibited a (45 ± 5)% signal reduction, while a 3D electrode geometry detector showed only a (5 ± 10)% reduction.
- 3D Geometry Innovation: 3D electrode geometry overcomes the inherent short mean drift distance of irradiated diamond by reducing the required charge carrier drift path by a factor of ~20 compared to planar devices of equal thickness.
- Fabrication Method: Femtosecond laser pulses are used to drill column electrodes in the diamond bulk, forming 50 µm × 50 µm pixel cells (4 bias columns + 1 central readout column).
- Future Direction: RD42 plans to test 25 µm × 25 µm 3D cells and increase fluence levels to fully map damage curves for HL-LHC and beyond.
Technical Specifications
Section titled “Technical Specifications”| Parameter | Value | Unit | Context |
|---|---|---|---|
| Detector Material | scCVD & pCVD Diamond | — | Tested as strip detectors |
| Strip Pitch | 50 | µm | Metallized electrodes |
| Test Beam Particle | 120 | GeV/c hadrons | MIP characterization |
| Proton Irradiation Energy | 800 | MeV | LANSC facility |
| Proton Irradiation Energy | 24 | GeV | CERN IRRAD |
| Proton Irradiation Energy | 70 | MeV | CYRIC, Tohoku University |
| Pion Irradiation Energy | 24 | GeV | CERN IRRAD |
| Neutron Source | TRIGA Nuclear Reactor | — | Jožef Stefan Institute |
| 3D Cell Pitch | 50 × 50 | µm | Femtosecond laser drilled |
| Future 3D Cell Pitch | 25 × 25 | µm | Planned for higher radiation tolerance |
| Drift Distance Reduction (3D vs Planar) | ~1/20 | ratio | 3D geometry advantage |
| Fluence at Comparison Point | 3.5 × 1015 | p/cm2 | 800 MeV proton benchmark |
| Planar Signal Reduction @ 3.5×1015 | 45 ± 5 | % | pCVD planar device |
| 3D Signal Reduction @ 3.5×1015 | 5 ± 10 | % | pCVD 3D device |
| 3D vs Planar Signal Boost (unirradiated) | ~2× | ratio | Intrinsic geometry advantage |
| Target Fluence for Future | 1017 | /cm2 | Comparable to 25 µm × 25 µm drift |
Key Methodologies
Section titled “Key Methodologies”- Sample Preparation: scCVD and pCVD diamond samples irradiated prior to metallization, then fabricated into strip detectors with 50 µm pitch.
- Irradiation Campaigns: Samples exposed to protons (24 GeV, 70 MeV, 800 MeV), pions (24 GeV), and reactor neutrons across multiple international facilities.
- Beam Testing: Pre- and post-irradiation characterization performed in a 120 GeV/c hadron beam (CERN) for MIP signal response.
- Damage Modeling: First-order damage model applied to describe the decrease of mean drift distance (λ) as a function of fluence.
- 3D Electrode Fabrication: Femtosecond laser used to drill column electrodes directly into the diamond bulk (no surface-only patterning).
- 3D Cell Architecture: 50 µm × 50 µm cells with four bias columns connected to bottom metallization and one central readout column connected to top metallization.
- Comparative Normalization: Signal normalized to pre-irradiated response to isolate radiation-induced degradation from intrinsic device differences.
6CCVD Solutions & Capabilities
Section titled “6CCVD Solutions & Capabilities”Applicable Materials
Section titled “Applicable Materials”- Optical/Electronic Grade SCD (Single Crystal Diamond): For replicating the scCVD strip detector baseline measurements, our optical-grade SCD substrates offer the low defect density and high carrier mobility required for intrinsic radiation tolerance characterization. Available thicknesses from 0.1 µm to 500 µm.
- Polycrystalline CVD (PCD) Plates: For the 3D geometry and high-fluence pCVD detector work, our PCD plates (up to 125mm diameter) provide the bulk material uniformity needed for femtosecond laser drilling of microelectrode arrays. Thicknesses from 0.1 µm to 500 µm, with substrates available up to 10mm for mechanical stability during handling.
- Boron-Doped Diamond (BDD): For potential charge-sensing or ohmic contact optimization in the metallization stack, our heavy boron-doped PCD can be specified.
Customization Potential
Section titled “Customization Potential”- Custom Metallization Stacks: The RD42 collaboration metallized samples after irradiation (50 µm pitch strips). 6CCVD offers in-house metallization with Au, Pt, Pd, Ti, W, and Cu — enabling Ti/Pt/Au or Cr/Au stacks typical of HEP detector fabrication. We can deposit patterned electrodes via lift-off or post-deposition lithography.
- Laser Cutting & Microfabrication Support: While 6CCVD specializes in precision laser cutting of diamond (not femtosecond bulk electrode drilling), we can supply precision-diced, pre-shaped pCVD substrates optimized for downstream femtosecond laser processing — reducing your fab yield loss.
- Surface Polishing: For 3D detector development, surface roughness impacts both metallization adhesion and laser focus quality. 6CCVD provides Ra < 1nm for SCD and < 5nm for inch-size PCD, ensuring clean entry/exit surfaces for bulk electrode drilling.
- Thickness Precision: The shift to 25 µm × 25 µm 3D cells requires thinner bulk material with precise thickness control. We can supply PCD at custom thicknesses to match your drift path optimization requirements.
Engineering Support
Section titled “Engineering Support”- PhD-Level Material Consultation: Our in-house PhD engineering team can assist with material selection for high-radiation detector projects — specifically addressing the trade-offs between scCVD (higher carrier mobility, lower trapping) and pCVD (lower cost, scalable to larger areas, proven in 3D geometry).
- Detector-Grade Material Specification: We can provide characterization data (Raman, XRD, birefringence imaging) to qualify diamond material for HL-LHC or similar radiation-hard detector applications.
- Prototyping to Production Scale: From single research substrates (mm-scale) to wafer-scale PCD plates (up to 125mm), 6CCVD supports both laboratory R&D and small-batch production runs.
Call to Action
Section titled “Call to Action”For custom specifications, material consultation, or to discuss how 6CCVD diamond can accelerate your radiation-hard detector development, visit 6ccvd.com or contact our engineering team directly.
View Original Abstract
Diamond is used as detector material in high energy physics experiments due to its inherent radiation tolerance. The RD42 collaboration has measured the radiation tolerance of chemical vapour deposition (CVD) diamond against proton, pion, and neutron irradiation. Results of this study are summarized in this article. The radiation tolerance of diamond detectors can be further enhanced by using a 3D electrode geometry. We present preliminary results of a poly-crystalline CVD (pCVD) diamond detector with a 3D electrode geometry after irradiation and compare to planar devices of roughly the same thickness.