Skip to content

Infrared vertical external cavity surface emitting laser threshold magnetometer

MetadataDetails
Publication Date2024-02-26
JournalApplied Physics Letters
AuthorsNathan S. Gottesman, Michael A. Slocum, Gary A. Sevison, Michael Wolf, Michal L. Lukowski
InstitutionsUniversity of Arizona, Wright-Patterson Air Force Base
Citations6
AnalysisFull AI Review Included

Infrared VECSEL NV-Diamond Magnetometer: Technical Documentation

Section titled “Infrared VECSEL NV-Diamond Magnetometer: Technical Documentation”
  • Core Innovation: The paper demonstrates the first infrared Laser Threshold Magnetometer (LTM) utilizing a vertical external cavity surface emitting laser (VECSEL) architecture integrated with an NV-center doped single crystal diamond (SCD) plate.
  • Material Application: A 3 mm × 3 mm × 500 µm SCD plate with an NV density of 300 ppb is utilized as an intracavity saturable absorber at 1042 nm, enhancing the 1042 nm singlet-state absorption transition.
  • Operating Wavelengths: The VECSEL operates at 1042.7 nm (single-frequency), pumped optically by an 808 nm pump laser, with NV polarization driven by a counter-propagating 532 nm pump.
  • Key Performance Metrics:
    • Best magnetic sensitivity: 7.5 nT/√Hz (10-50 Hz band, limited by VECSEL technical noise).
    • Best projected PSNL sensitivity: 26.6 pT/√Hz.
    • ODMR contrast: 18.4% at the transition frequency of 2.8229 GHz.
  • Critical Observations: Near-threshold operation yields a nonlinear contrast enhancement attributed to an unexpected saturable absorption behavior, which improves both contrast and projected PSNL sensitivity beyond theoretical models.
  • Engineering Bottleneck: Device performance is currently limited by VECSEL amplitude stability and technical noise rather than quantum spin projection noise.

ParameterValueUnitContext / Condition
NV Density300ppbSingle crystal diamond intracavity plate
Spin Dephasing Time (T2*)1µsCharacteristic ensemble coherence time
Diamond Plate Dimensions3 × 3 × 0.5mm × mm × mmLength × Width × Thickness
Zero-Field Splitting (D)≈ 2.87GHzGround state triplet splitting
ODMR Transition Frequency2.8229GHz∆ms = −1 transition (biased)
Bias Magnetic Field1.682mTApplied via permanent ring magnets
Hyperfine Constant2.158MHz14N nuclear interaction
Resonance Linewidth (∆ν)1.98 ± 0.0508MHzPower-independent Lorentzian width
Laser Wavelength1042.7nmVECSEL single-frequency operation
532 nm Pump Power1.2WNV spin polarization source
808 nm Pump Threshold (PThresh)4.33WVECSEL pump power at threshold
TEM00 Mode Waist (2ws)≈ 80µmTight focus at diamond plane
Output Coupler Reflectivity (Rs)97 ± 0.5%At 1042 nm
Cold Plate Temperature19.75°CMaintained via Peltier cooler
Best Magnetic Sensitivity7.5nT/√Hz10 Hz to 50 Hz noise band
Best Projected PSNL Sensitivity26.6pT/√HzLimit imposed by photon shot noise
Maximum ODMR Contrast18.4%Measured near lasing threshold
Equivalent Noise Bandwidth≈ 78HzAt 1 ms LIA time constant
Output Optical Power (sensitivity test)28µWLow-power technical noise characterization

  • Diamond Sample Preparation:
    • Fabricated a 3 mm × 3 mm × 500 µm SCD plate via chemical vapor deposition.
    • Antireflection coating applied using a single layer of Al2O3 optimized for 1042 nm to suppress parasitic Fresnel reflections at the diamond facets.
  • VECSEL Gain Chip Assembly:
    • Processed a ½-VCSEL from an MOCVD-grown GaAs wafer.
    • Structure: 12 compressively strained InGaAs quantum wells with GaAs barriers and strain-compensating GaAsP layers.
    • Backed by 25 pairs of AlGaAs/AlAs DBR (Rs > 99.9%).
    • DBR solder-bonded to a polycrystalline diamond heat spreader.
    • Substrate removed via wet chemical etching; AR coating of single SiO2 layer applied via electron beam evaporation for 808 nm.
  • Cavity Geometry (“V-Shaped”):
    • Composed of the diamond sample, 1 mm BRF, 50 mm radius of curvature HR mirror, and a plane output coupler.
    • Cavity tuned to 1042.7 nm using the BRF; single-frequency operation verified via 10 GHz scanning Fabry-Perot interferometer.
    • Microwave loop antenna placed adjacent to the diamond surface.
  • Optical Alignment & Detection:
    • 532 nm pump delivered via dichroic mirror counter-propagating through the output coupler.
    • 1042 nm output focused onto a silicon avalanche photodiode (250 mm focal length lens).
    • 937 nm longpass filter placed before the detector to block NV photoluminescence.
  • ODMR and Sensitivity Calibration:
    • Permanent ring magnets biased the NV axis at 1.682 mT.
    • Microwave probe (5 kHz square wave amplitude modulation, ≈ 25 dBm at the antenna) generated via SR386 signal generator and ZHL-5W-63S+ amplifier.
    • Detection via SR865A lock-in amplifier combined with a SIM960 PID controller and ≈ 10 Hz RC filter for active VECSEL power stabilization.
    • Magnetic sensitivity calculated from voltage-frequency conversion factors and averaged over 10 separate 10-second traces.

The successful execution of an infrared VECSEL-based Laser Threshold Magnetometer depends critically on the optical, thermal, and quantum properties of the intracavity diamond plate. The following outlines how 6CCVD capabilities map directly to the requirements of this research.

  • Applicable Materials:

    • Optical Grade SCD (Single Crystal Diamond): The paper utilized a 3 mm × 3 mm × 500 µm SCD plate. 6CCVD manufactures Optical Grade SCD with thicknesses from 0.1 µm to 500 µm, perfectly matching the intracavity geometry. Our bulk substrates (up to 10 mm) also support future iterations requiring thicker sensing volumes for higher NV interaction lengths.
    • Custom NV Doping Profiles: While the paper used 300 ppb, 6CCVD works closely with research clients to provide tailored nitrogen-vacancy ensembles optimized for specific T2* targets and infrared absorption cross-sections.
  • Customization Potential:

    • Antireflection Coatings: The paper relied on a single-layer Al2O3 coating for 1042 nm. 6CCVD offers custom dielectric coating design and deposition to achieve sub-1% reflectance at specific lasing wavelengths, which is critical for suppressing parasitic cavity losses.
    • Custom Metallization and Laser Cutting: For experiments requiring direct integration of microwave antennas or electrodes onto the diamond surface, 6CCVD provides in-house metallization with Au, Pt, Pd, Ti, W, and Cu, paired with precision laser cutting and shaping services.
    • Ultra-Low Surface Roughness: Surface imperfections interact heavily with the tightly focused TEM00 mode (2ws ≈ 80 µm). 6CCVD provides sub-nanometer polishing (Ra < 1 nm for SCD), directly reducing scattering losses in demanding VECSEL cavity geometries.
  • Engineering Support:

    • 6CCVD’s in-house PhD engineering team can assist with material selection, NV center density optimization, and AR coating design for quantum sensing, VECSEL, and intracavity spectroscopy applications.
    • We routinely support clients pushing the boundaries of cavity-enhanced magnetometry, providing the precision diamond optics necessary to advance photon shot noise limited sensitivity.
  • Call to Action:

    • For custom specifications, NV-doped sample requests, or material consultation, visit 6ccvd.com or contact our engineering team directly.
View Original Abstract

Nitrogen-vacancy (NV) centers have considerable promise as high sensitivity magnetometers; however, they are commonly limited by inefficient collection and low contrasts. Laser threshold magnetometry (LTM) enables efficient collection and high contrasts, providing a path toward higher sensitivity magnetometry. We demonstrate an infrared LTM using an ensemble of NV centers in a single-crystal diamond plate integrated into a vertical external cavity surface emitting laser. The laser was tuned to the spin-dependent absorption line of the NV centers, allowing for optical readout by monitoring the laser output power. We demonstrate a magnetic sensitivity of 7.5 nT/Hz in the frequency range between 10 and 50 Hz. Furthermore, the contrast and the projected photon shot noise limited (PSNL) sensitivity are shown to improve significantly by operating close to the lasing threshold, achieving 18.4% and 26.6 pT/Hz near the threshold. In addition, an unexpected saturable absorption phenomenon was observed near the threshold, which enhanced the contrast and projected PSNL sensitivity.

  1. 2017 - Magnetoencephalography for brain electrophysiology and imaging [Crossref]
  2. 2005 - The historical development of the magnetic method in exploration [Crossref]
  3. 2020 - Magnetic field fingerprinting of integrated-circuit activity with a quantum diamond microscope [Crossref]
  4. 2020 - Broadband multi-magnon relaxometry using a quantum spin sensor for high frequency ferromagnetic dynamics sensing [Crossref]
  5. 2016 - Absolute positioning using the Earth’s magnetic anomaly field: Magnetic anomaly [Crossref]
  6. 2020 - Sensitivity optimization for NV-diamond magnetometry [Crossref]
  7. 2020 - Diamond magnetometer enhanced by ferrite flux concentrators [Crossref]
  8. 2023 - High sensitivity of diamond nitrogen-vacancy magnetometer with magnetic flux concentrators via enhanced fluorescence collection [Crossref]
  9. 2023 - Nuclear quadrupole resonance spectroscopy with a femtotesla diamond magnetometer [Crossref]
  10. 2010 - Monolithic diamond optics for single photon detection [Crossref]