Technical Documentation: All-Carbon Schottky Contacts for NV Center Magnetic Resonance Detection

Section titled “Technical Documentation: All-Carbon Schottky Contacts for NV Center Magnetic Resonance Detection”
  • Breakthrough Approach: The paper demonstrates a novel all-carbon graphitic-diamond-graphitic device functioning as two back-to-back Schottky diodes, enabling purely electrical readout of Nitrogen-Vacancy (NV) center spin resonances without conventional ohmic contacts.
  • Material Insight: Under 561 nm illumination, the NV center ensemble generates electron-hole pairs that transform a lightly doped type IIa diamond (1 ppm N, ~50 ppb B) into a p-type semiconductor, enabling localized Schottky barrier formation at graphitic electrodes.
  • Physical Mechanism: Spin-dependent thermionic emission across the reverse-biased Schottky junction produces a photocurrent modulated by RF-driven NV− spin transitions, with a measured zero-field splitting (ZFS) of 2.87 GHz.
  • Contrast Performance: Photoelectric Detection of Magnetic Resonance (PDMR) contrast reaches up to ~18% under optimal conditions, with electric contrast exceeding optical contrast via a field-effect mechanism tied to depletion region (DR) modulation.
  • Electrode Fabrication: Graphitic electrodes of 50 × 50 µm2 (200 µm gap) are created via Xenon Focused Ion Beam (FIB) implantation at a dose of 4×1015 cm−2 (30 keV), yielding optically semi-transparent contacts (~70% transmission).
  • Quantum Sensing Application: Establishes a pathway for miniaturized NV-based magnetometry, electrometry, thermometry, and RF sensing with simplified wiring (e.g., parallel-plate architectures).
ParameterValueUnitContext
Diamond Material GradeType IIa (Optical Grade)—Element Six (E6) CVD-grown single crystal
Nitrogen Concentration1ppmDominant dopant
NV Center ConcentrationFewppbCreation yield ~0.3%
Boron Concentration~50ppbParasitic CVD doping
Crystal Orientation⟨100⟩ / ⟨110⟩ side facets—Optically polished side facets
Laser Wavelength (Pumping)561nmCW green excitation (Cobolt Jive)
NV− Zero-Field Splitting (D)2.87GHzGround state triplet splitting
Gyromagnetic Ratio (γe)28GHz/TFor magnetic field Zeeman shift
ZPL NV0575nmNeutral charge state
ZPL NV−637nmNegative charge state
Electrode Dimensions50 × 50µm2Graphitic contacts
Inter-Electrode Gap200µmLateral separation
Electrode ThicknessFewnmXenon FIB-induced graphitization
Electrode Optical Transmission~70%Allows simultaneous ODMR imaging
Xenon Implantation Dose4×1015cm−2Ion beam parameter
Xenon Implantation Energy30keVIon beam parameter
Applied Bias Voltage Range0 to ±300VDC bias across structure
Laser Power Range65 to 400mWAt laser output
Beam Waist Range (w0)6.4 to 11.9µmAt electrode area
Pump Intensity (Active Area)~100kW/cm265 mW with 6.4 µm waist
RF Power25dBmDriving NV− spin transitions
Transition Voltage (400 mW, 11.9 µm)~100VDR reaches illumination depth limit
Field Gradient Resonance (Electrode A)1.98GHzNV− ∣0⟩→∣±1⟩ transition
Field Gradient Resonance (Electrode B)2.02GHzNV− ∣0⟩→∣±1⟩ transition
Simulated Hole Density (p0)1.28×1014cm−3Under laser illumination
Conductive Channel Depth (D)16.8µmGaussian beam penetration depth
PDMR Maximum Contrast~18%Best at 400 mW, 100-125 V bias
ODMR/PDMR Measurement Time~6 / ~9minFor 250 frequency points
Diamond Band Gap5.5eVReference parameter
  • Diamond Sample Preparation: Use a ⟨100⟩-oriented type IIa optical grade CVD single crystal diamond with 1 ppm nitrogen and ~50 ppb boron; polish side facets to optical quality without post-growth irradiation or annealing.
  • Graphitic Electrode Fabrication: Create 50 × 50 µm2 graphitic electrodes separated by 200 µm via Xenon Focused Ion Beam (FIB) implantation at a dose of 4×1015 cm−2 and energy of 30 keV to convert a surface diamond layer into amorphous/graphitic carbon.
  • Optical Pumping: Apply continuous-wave (CW) green laser excitation at 561 nm through a 5 cm lens focused on the side facet of the diamond, creating an optical path between the two electrodes.
  • Beam Profiling: Adjust the beam waist (w0) between 6.4 µm and 11.9 µm using an afocal doublet to tune the conductive channel depth beneath the electrodes.
  • Electrical Readout Setup: Apply a DC bias voltage from a high-voltage Source Measure Unit (SMU, Keithley 2470) ranging from 0 to ±300 V across the graphitic contacts and monitor photocurrent.
  • RF Excitation: Drive NV− spin transitions using a loop antenna centered over the electrodes at the zero-field resonance frequency of 2.87 GHz with 25 dBm RF power.
  • Magnetic Field Mapping: Apply a static magnetic field with a gradient along one ⟨111⟩ diamond axis via a neodymium permanent magnet to spatially separate the four NV center families by resonance frequency (1.98 GHz at A, 2.02 GHz at B).
  • Optical Readout: Collect photoluminescence through a Mitutoyo M Plan Apo 10× objective (NA 0.28) with NV0 (584/40 nm) or NV− (698/70 nm) bandpass filters onto a CMOS camera.
  • Depletion Region Visualization: Acquire ΔPL images by subtracting PL frames at applied bias (e.g., +150 V) from frames at 0 V bias using NV− and NV0 filters to image band bending effects.
  • COMSOL Multiphysics Simulation: Model the electric field profile and DR extension as a function of bias voltage assuming a homogeneous hole density of 1.28×1014 cm−3 over a 16.8 µm depth.
  • Optical Grade SCD (Single Crystal Diamond): The research uses a type IIa ⟨100⟩ optical grade single crystal diamond with controlled nitrogen (~1 ppm) and trace boron (~50 ppb) doping. 6CCVD supplies high-purity optical grade SCD substrates with precisely tuned nitrogen content suitable for NV ensemble magnetometry.
  • Boron-Doped (BDD) Substrates: For researchers seeking to enhance the p-type conductivity or modify the boron-to-nitrogen compensation ratio, 6CCVD offers custom boron-doped SCD and PCD with controllable dopant concentrations.
  • Polycrystalline Diamond (PCD) Wafers: For scalable, cost-effective production of NV sensor arrays, 6CCVD’s inch-size PCD wafers (polished to Ra < 5 nm) provide an alternative geometry suitable for large-area Schottky device arrays.
  • Custom Crystallographic Orientation: 6CCVD provides ⟨100⟩, ⟨110⟩, and ⟨111⟩-oriented SCD substrates with optical-grade side-facet polishing capabilities for lateral illumination schemes like the one demonstrated.
  • Laser Cutting & Micro-Fabrication: 6CCVD offers laser cutting and shaping services to produce non-standard geometries, micro-channels, and tailored side-facet surfaces required for side-pumped NV sensing devices.
  • Doping Engineering: Custom nitrogen and boron doping profiles during MPCVD growth can be specified to achieve the precise NV-center yield (~0.3% demonstrated) and charge compensation dynamics required for Schottky-based readout.
  • Surface Preparation: Polishing capabilities include Ra < 1 nm for SCD surfaces, enabling high-quality graphitic electrode formation via ion implantation or alternative metallization schemes.
  • 6CCVD’s in-house PhD engineering team provides consultation on material selection for NV-center quantum sensing projects, including magnetometry, electrometry, thermometry, and RF sensing applications.
  • Technical guidance is available for replicating the Schottky-contact device architecture, including recommendations on crystal orientation, doping profiles, and thickness selection (SCD/PCD thickness range: 0.1 µm to 500 µm; substrates up to 10 mm).
  • Metallization Support: For variants of this all-carbon device requiring hybrid metal contacts, 6CCVD provides in-house metalization with Au, Pt, Pd, Ti, W, and Cu to fabricate Schottky or ohmic electrodes tailored to specific barrier heights.

For custom specifications, tailored doping concentrations, or material consultation for NV-center quantum sensor projects, visit 6ccvd.com or contact our engineering team directly.

View Original Abstract

The nitrogen-vacancy (NV) center is a defect in diamond whose spin state can be read optically by exploiting its photoluminescence or electrically by exploiting its charge generation rate under illumination, both of which being spin-dependent. The latter method offers numerous opportunities in terms of integration and performance compared to conventional optical readout. Here, we investigate the physical properties of a graphitic-diamond-graphitic structure under illumination. We show how, for a type IIa diamond material, electron-hole pairs generated by an ensemble of NV centers lead to a p-type material upon illumination, making this all-carbon structure equivalent to two back-to-back Schottky diodes. We analyze how the reverse current flowing upon illumination changes as a function of bias voltage and radiofrequency-induced excitation of the NV ensemble spin resonances. Furthermore, we demonstrate how an additional field effect arising from the illumination scheme affects the reverse current, resulting in a photoelectrical signal that can exceed the optical signal under the same illumination conditions. Xuan Phuc Le and colleagues report on the photoelectric detection of spin resonances in nitrogen-vacancy centres in a graphitic-diamond-graphitic structure. Behaving like two back-to-back Schottky diodes, it produces an enhanced photoelectric signal.