Enhanced Mass Transfer via Brush Electrode for Significantly Promoted Electrochemical Oxidation of Organic Pollutants
Paper details
Section titled “Paper details”| Field | Value |
|---|---|
| Journal | Water |
| Published | 2026-05-06 |
| Authors | Kai Wang, Guangsen Xia, Yonggang Jia, Yibao Wang, L Zhang |
| DOI | 10.3390/w18091110 |
A three-dimensional polyacrylonitrile-based carbon fiber brush removed 90.5% of total organic carbon from 50 mmol/L oxalic acid at 400 mA over 240 min. The boron-doped diamond and Ti/IrO2-Ta2O5 plate anodes removed 57.5% and 6.6% under the same conditions. The brush consumed 5.5 to 8.9 kWh/kgTOC, compared with 11.2 to 19.3 and 76.1 to 120.7 kWh/kgTOC. This advantage applied to oxalic acid, which the brush oxidized mainly by direct electron transfer. It did not extend to phenol or PFOA, where carbon-fiber instability and weak reactive oxygen species generation limited performance.
Oxalic acid performance and stability
Section titled “Oxalic acid performance and stability”At 5 mmol/L oxalic acid, the same 400 mA test gave 65.7% TOC removal with PAN-CFB, 43.2% with BDD, and 7.8% with Ti/IrO2-Ta2O5. The higher oxalic acid concentration improved mass transfer and lowered the energy required by each anode. PAN-CFB consumed 24.2 to 107.8 kWh/kgTOC at 5 mmol/L, compared with 5.5 to 8.9 kWh/kgTOC at 50 mmol/L.
Constant-potential tests separated direct oxidation from indirect oxidation. At 1.3 V vs. SCE, the brush removed 72.7% of TOC from 5 mmol/L oxalic acid and 92.1% from 50 mmol/L after 180 min. The authors found no effective hydrogen peroxide, ozone, or hydroxyl radical generation at this potential. They therefore attributed the removals to direct anodic oxidation.
Carbon-fiber decomposition became visible at low reactant concentration. TOC rose from 41.2 to 51.5 mg/L after 120 min under 400 mA, and the solution turned yellow. The authors associated this result with electrode decomposition under poor mass transfer.
Test cell and measurement method
Section titled “Test cell and measurement method”The PAN-CFB anode was made by twisting 2 g of 7 µm polyacrylonitrile-based carbon fiber between a two-wire titanium core. PAN-CFF used the same carbon-fiber mass and matched the 85 mm × 50 mm plate area. This felt electrode separated brush geometry from carbon composition. The BDD plate had the same dimensions and was deposited by hot-wire chemical vapor deposition on niobium.
Electrolysis used an open undivided cell measuring 5 cm × 5 cm × 23 cm with 0.5 L solution. A pure titanium mesh served as cathode, a saturated calomel electrode was the reference, and the electrode spacing was 1 cm. The support electrolyte was 0.1 mol/L sodium sulfate, and the solution was stirred at 300 rpm.
Oxalic acid and phenol were tested at 5 and 50 mmol/L. PFOA was tested at 5 mmol/L because its solubility was about 8.2 mmol/L at 20 °C. A TOC analyzer measured samples of about 3.0 mL every 30 min. Separate tests without power found negligible pollutant removal by adsorption. Energy calculations used cell voltage in a two-electrode configuration.
Mass transfer evidence
Section titled “Mass transfer evidence”Linear sweep voltammetry covered 0 to 3.0 V vs. SCE at 10 mV/s in 0.5 mol/L sodium sulfate. Onset potentials were taken at 0.05 A. The measured values separate oxygen evolution performance from direct oxalic acid oxidation.
| Anode | Oxygen evolution onset, V vs. SCE | Oxalic acid oxidation onset, V vs. SCE | Oxalic acid mass-transfer coefficient, m/s |
|---|---|---|---|
| PAN-CFB | 1.20 | 0.78 | 3.3 × 10⁻⁵ |
| PAN-CFF | 1.37 | 0.80 | 9.0 × 10⁻⁶ |
| BDD | 2.23 | 2.00 | 9.0 × 10⁻⁷ |
| Ti/IrO2-Ta2O5 | 1.05 | No clear direct oxidation | Not reported |
At 1.3 V vs. SCE, background-subtracted oxalic acid oxidation currents were 0.47 A for PAN-CFB and 0.20 A for PAN-CFF in 5 mmol/L oxalic acid. BDD produced only 1.9 × 10⁻⁵ A. At 50 mmol/L, the currents rose to 1.3 A, 0.31 A, and 2.0 × 10⁻⁴ A.
The authors linked the brush result to its open geometry. More fibers contact the electrolyte without shielding, while nonlinear diffusion shortens the transport distance to each filament. Earlier work by the same group found 20 times higher oxygen-reduction activity for PAN-CFB than PAN-CFF at about 40 mg/L dissolved oxygen.
Phenol reverses the performance ranking
Section titled “Phenol reverses the performance ranking”At 1.3 V vs. SCE, PAN-CFB and BDD each removed less than 10% of phenol TOC after 180 min. The brush current was about 0.04 A, compared with 5 × 10⁻⁵ A for BDD. The similar TOC results showed that direct oxidation contributed little to mineralization on either electrode.
Reactive oxygen species produced by BDD drove most phenol removal. At 400 mA for 3 h, 5 mmol/L phenol gave 34.6% TOC removal with BDD, 4.4% with PAN-CFB, and 2.2% with Ti/IrO2-Ta2O5.
At 50 mmol/L, removals were only 6.3%, 6.2%, and 2.8%, respectively. The 50 mmol/L phenol solution began at 3,600 mg/L TOC, so these low percentages covered more organic carbon. BDD used 78.7 to 98.2 kWh/kgTOC for the 5 mmol/L test, versus 498.7 to 611.4 for PAN-CFB. The authors proposed electrode fouling and an electropolymerized phenol film as reasons brush oxidation was not sustained.
PFOA exposes the stability limit
Section titled “PFOA exposes the stability limit”No electrode showed useful direct PFOA oxidation at 1.3 V vs. SCE. Each produced less than 5% TOC removal, with oxidation currents between 10⁻⁵ and 0.03 A.
At 400 mA for 5 mmol/L PFOA, BDD exceeded 70% TOC removal within 180 min. Ti/IrO2-Ta2O5 removed less than 3%, while PAN-CFB reached approximately -14.4%. The brush solution turned yellow as small carbon species entered the water. Its energy consumption was not calculated because TOC removal was negative.
BDD consumed 13.8 to 42.0 kWh/kgTOC, whereas Ti/IrO2-Ta2O5 required 279.4 to 959.1 kWh/kgTOC. A prior study placed BDD PFOA oxidation above 2.76 V vs. SCE. At that potential, vigorous oxygen evolution would occur on PAN-CFB, while the brush was susceptible to damage and decomposition.
Electrode selection depends on pollutant chemistry
Section titled “Electrode selection depends on pollutant chemistry”| Pollutant and test | PAN-CFB TOC removal | BDD TOC removal | Ti/IrO2-Ta2O5 TOC removal | Main result |
|---|---|---|---|---|
| 50 mmol/L oxalic acid, 400 mA, 240 min | 90.5% | 57.5% | 6.6% | PAN-CFB leads through direct oxidation and mass transfer |
| 5 mmol/L phenol, 400 mA, 3 h | 4.4% | 34.6% | 2.2% | BDD leads through indirect oxidation |
| 5 mmol/L PFOA, 400 mA, 180 min | -14.4% | Over 70% | Less than 3% | BDD leads; PAN-CFB decomposes |
The rows are not direct performance equivalents because concentration, time, and oxidation pathway differ. They show why one anode cannot replace another across the tested pollutants.
Oxalic acid favored the brush because direct electron transfer dominated and mass transfer controlled the rate. Phenol and PFOA favored BDD because its 2.23 V vs. SCE oxygen evolution onset supported reactive oxygen species generation and direct oxidation.
For BDD anode design, the study therefore points to a tradeoff. A plate provides high oxygen evolution potential and broad oxidation capability, but the brush had a higher oxalic acid mass-transfer coefficient and greater electrochemically active surface area.
The carbon brush is not a stable general replacement. Its oxygen evolution onset was 1.20 V vs. SCE, and decomposition worsened during low-concentration oxalic acid treatment. The authors propose a stable three-dimensional BDD brush that combines high oxygen evolution potential with mass-transfer improvement.
The experiments used a 0.5 L synthetic sodium sulfate solution, constant stirring, and an undivided cell. They did not establish long-term electrode life, scale-up performance, or treatment of real wastewater.
Materials and support
Section titled “Materials and support”The study used an 85 mm × 50 mm boron-doped diamond plate anode on a niobium substrate for electrochemical oxidation cells. The 6CCVD diamond materials catalog lists MPCVD-grown boron-doped diamond and plates or wafers up to 125 mm, matching the required material family and size range. The engineering support page can be used to discuss custom fabrication for that anode format.
View Original Abstract
Electrochemical oxidation (EO) possesses numerous advantages and great potential for organic pollutant degradation. However, traditional plate anodes for EO are limited by pollutant mass transfer, leading to low oxidation efficiency and high energy consumption. Herein, a three-dimensional (3D) polyacrylonitrile-based carbon fiber brush (PAN-CFB) anode was employed to enhance mass transfer and improve oxidation efficiency. The oxidation capacity of the PAN-CFB anode was compared with those of boron-doped diamond (BDD) and Ti/IrO2-Ta2O5 plate anodes using oxalic acid (OA), phenol, and perfluorooctanoic acid (PFOA) as target pollutants, respectively. Experimental results demonstrated that the 3D PAN-CFB anode exhibits superior direct oxidation capacity compared to BDD and the Ti/IrO2-Ta2O5 plate anode in degrading OA, which is attributed to the significantly enhanced mass transfer of OA toward the brush anode surface. Under a constant current of 400 mA for 240 min, the total organic carbon (TOC) removal from 50 mmol/L OA reached 90.5%, 57.5% and 6.6% for PAN-CFB, BDD and the Ti/IrO2-Ta2O5 anode, respectively, and the energy consumption followed the order of PAN-CFB (5.58.9 kWh/kgTOC) < BDD (11.219.3 kWh/kgTOC) < Ti/IrO2-Ta2O5 (76.1~120.7 kWh/kgTOC). However, the 3D PAN-CFB anode exhibited poor stability at high potential and failed to promote phenol and PFOA degradation due to the weak direct oxidation capacity toward the two pollutants and the poor generation capacity of reactive oxygen species, associated with its low oxygen evolution potential. Therefore, future efforts should focus on developing stable 3D brush electrodes with a higher oxygen evolution potential to enable non-selective oxidation of a broader range of pollutants.
Boron Doped Diamond On Titanium Bdd Electrode
View Specs →
Boron Doped Diamond Electrode On Niobium Bdd Nb Electrode
View Specs →
Boron Doped Single Crystal Diamond Plate
View Specs →Original source
Section titled “Original source”References
Section titled “References”- 2024 - Electrocatalytic oxidation for organic wastewater: Recent progress in anode material, reactor, and process combination [Crossref]
- 2025 - Advanced electrochemical oxidation and membrane distillation for the treatment of landfill leachate concentrated by reverse osmosis [Crossref]
- 2021 - Anodic oxidation of organic pollutants: Anode fabrication, process hybrid and environmental applications [Crossref]
- 2023 - Prospective Life Cycle Assessment for the Electrochemical Oxidation Wastewater Treatment Process: From Laboratory to Industrial Scale [Crossref]
- 2024 - A comprehensive review of the electrochemical advanced oxidation processes: Detection of free radical, electrode materials and application [Crossref]
- 2022 - Bi5+ doping improves the electrochemical properties of Ti/SnO2-Sb/PbO2 electrode and its electrocatalytic performance for phenol [Crossref]
- 2021 - Electrochemical oxidation of 2-chloroaniline in single and divided electrochemical flow cells using boron doped diamond anodes [Crossref]
- 2021 - Electrochemical advanced oxidation for treating ultrafiltration effluent of a landfill leachate system: Impacts of organics and inorganics and economic evaluation [Crossref]
- 2021 - Fabrication of sulfur-doped TiO2 nanotube array as a conductive interlayer of PbO2 anode for efficient electrochemical oxidation of organic pollutants [Crossref]
- 2025 - Recent advances in titanium-based boron-doped diamond electrodes for enhanced electrochemical oxidation in industrial wastewater treatment: A review [Crossref]