A boron-doped diamond coating gave a CNMA120408 cemented carbide insert a self-temperature-sensing function during aluminum-alloy turning. Readings differed by less than 5% from infrared thermography at cutting depths of 20, 30, 40, and 50 µm. The tool responded in 1.3 s, close to the 1.2 s response of its thermocouple reference.

The coated insert combined cutting and sensing in one component. Silver-paste electrodes contacted the lateral sides of the BDD coating, while epoxy protected the contacts and lead wires. High-temperature tape secured the wires to the holder. The BDD element measured the tool-workpiece contact zone directly.

The coating approach retained BDD sensing on a commercial carbide insert. The authors designed it to avoid the high cost and difficult post-machining of monolithic diamond tools. They expected lower cost and stronger compatibility with commercial tool designs.

Intrinsic diamond has a 5.5 eV band gap. Substitutional boron creates acceptor levels near the top of the valence band, with an ionization energy of approximately 0.37 eV. Thermal excitation then ionizes these acceptors and creates mobile holes. The material becomes a P-type semiconductor, and an applied electric field carries current through the coating.

From room temperature to 300 °C, acceptor ionization dominates carrier transport without intrinsic excitation. Hole concentration rises sharply as temperature increases, while phonon scattering lowers mobility more slowly. The concentration change controls resistivity and produces the negative temperature coefficient used for sensing.

After grinding and polishing to a mirror finish, inserts were ultrasonically cleaned in acetone and ethanol. The BDD layer was deposited by hot filament chemical vapor deposition on a T600 system.

HFCVD conditionValue
Total gas flow rate400 mL min⁻¹
Hot filaments6, spaced 10 mm
Hot-filament temperature2400 °C
Filament-to-substrate distance5 mm
Growth pressure2.5 kPa
Substrate temperature800 to 850 °C
Deposition time6 h
Carbon source concentration1.0%

EDS mapping found homogeneous carbon and boron, with 9.23 at.% boron. SEM showed a continuous, dense polycrystalline film with truncated octahedral facets. Its grains were finer than undoped CVD diamond, and laser microscopy measured an areal roughness of Sa = 0.557 µm.

Cross-sectional SEM found a coating about 200 µm thick. The interface showed mechanical interlocking without visible microvoids or transverse cracks. Raman spectroscopy produced a sharp 1337 cm⁻¹ sp³ diamond peak. The 5 cm⁻¹ shift above natural diamond suggested residual compressive stress. A broad 1522 cm⁻¹ band indicated minor sp² or amorphous carbon at grain boundaries. The dominant sp³ peak led the authors to conclude that heavy doping did not significantly compromise the tetrahedral framework.

The JR-1010TG platform heated the tool tip from 0 to 250 °C through point contact. The setup was intended to reproduce heat conduction at the cutting tip. A CXT2518-4 instrument recorded resistance every 10 °C in three independent runs. Repositioning the tip in the same fixture kept contact pressure consistent.

Three runs produced the linear relation y = 6.46773 - 0.01451x with R² = 0.9923. Repeatability error reached a maximum of 1.87% at 110 °C and a minimum of 0.14% at 190 °C.

At 50 °C, resistance was recorded for 800 s and converted through the calibration. Temperature stayed within ±0.4 °C, with no deviation above 1 °C.

Under a transient laser source, the tool responded in 1.3 s and reached 121.49 °C. The thermocouple responded in 1.2 s and reached 127.47 °C. It returned to room temperature in about 2 s, while the coated tool cooled more slowly. The authors attributed both peak and cooling differences to the thermocouple junction’s smaller thermal volume and the carbide insert’s larger thermal inertia.

Electrodes connected to a 5V DC system that stabilized, amplified, and filtered the resistance signal. An ADS1115 acquired the analog data, and an STM32F103C8T6 drove a local OLED display. A JDY-31 Bluetooth module transmitted records to a host computer.

Turning tests used a CK6065-A CNC lathe and aluminum-alloy round bars. Spindle speed was 250 r/min, feed was 0.25 mm/r, and depth of cut varied among 20, 30, 40, and 50 µm.

A K-type thermocouple sat 1.5 mm from the tip and recorded through a YET-610L thermometer. Its trace showed thermal lag because the junction sat behind the tip and heat attenuated along the tool. The spherical junction geometry also affected heat dissipation. The BDD and thermocouple curves agreed in their temperature changes, although their absolute values differed.

An infrared camera used emissivity 0.75. Its maximum temperatures were 54.7, 65.4, 73.7, and 87.8 °C at the four depths. The BDD plateau values differed by less than 5%.

Table 2 reports the following comparison.

ToolCalibration rangeCutting rangeResponseReported accuracy
Ti(C,N)-LaCrO₃-Y₂O₃ laminated ceramic184 to 700 °CRoom temperature to 200 °CAbout 2.0 sDeviation above 8%
NiCr-NiSi thin-film thermocouple0 to 600 °CRoom temperature to 182 °CAbout 1.2 sIR deviation 3.90% to 10.78%; repeatability error 4.9%
Locally boron-doped diamond, LBDDRoom temperature to 125 °CRoom temperature to 80 °C91 to 242 msResolution 0.1 °C; fluctuation ±0.17 °C
Boron-hydrogen co-doped diamond, BHDDRoom temperature to 300 °CRoom temperature to 282 °C123 to 164 msResolution 0.1 °C
This coated toolRoom temperature to 300 °CRoom temperature to 110 °CAbout 1.3 sRepeatability ≤1.87%; fluctuation ≤±0.4 °C; IR deviation below 5%

The coated tool’s 1.3 s response was close to the thin-film thermocouple’s 1.2 s and faster than the ceramic tool’s about 2.0 s. It was slower than the LBDD and BHDD tools. Its infrared deviation was below the thin-film tool’s maximum of 10.78%, although that tool reported a lower value of 3.90%. The authors position the coated design for conventional continuous cutting with simpler fabrication and lower cost than monolithic BDD tools.

The paper gives two range descriptions. The calibration setup covered 0 to 250 °C, and the conclusion calls this the effective calibrated range. It also states that stable operation can extend from room temperature to 300 °C. Table 2 instead labels calibration as room temperature to 300 °C. Engineers would need to resolve that difference before transferring the design.

The authors state that the tool cannot cover temperatures above 400 °C, including cutting of titanium alloys and hardened steels. They also note possible conductivity degradation in BDD under heavy-duty roughing. The silver-paste and epoxy electrode system may fail under severe vibration despite reliable finishing-cut use.

The sensing element reports one contact-zone temperature and cannot map the rake face. Turning validation covers aluminum alloy at one speed and feed. The paper reports turning temperature results but no coating cost or insert wear-life data.

The model assumes a linear resistance-temperature response from 0 to 300 °C, acceptor-ionization control, representative point contact, and constant infrared emissivity of 0.75. Future work targets a 500 °C range, sputtered thin-film electrodes, multiple sensing points, and combining sensing data with artificial intelligence for tool-wear prediction. The demonstrated use is real-time monitoring during conventional aluminum-alloy cutting, with a 1.3 s response and no demonstrated multipoint mapping.

The paper’s material requirement is a boron-doped diamond sensing layer on a cemented carbide cutting insert, with a protected electrode connection. 6CCVD’s diamond materials catalog lists MPCVD-grown boron-doped diamond and metallization with Au, Pt, Pd, Ti, W, or Cu, although the study used HFCVD and silver-paste electrodes. The engineering support service can assess the coating, contact, and signal integration requirements for a specified tool architecture.

View Original Abstract

Real-time cutting temperature monitoring is critical for metal cutting. Contact and non-contact measurement methods both have inherent limitations. This study developed a boron-doped diamond (BDD) coated cemented carbide intelligent tool with self-temperature-sensing capability. The BDD coating was prepared via the HFCVD method. We characterized the microstructural and elemental properties of the coated tool. A precise resistance-temperature calibration of the tool was conducted. A closed-loop signal acquisition and remote monitoring system was designed for the tool. Static and dynamic performance tests verified the tool’s good repeatability and stability. Its dynamic response was comparable to that of a thermocouple. Turning experiments were carried out with aluminum alloy workpieces. The tool’s temperature measurement results were compared with those of a thermocouple and an infrared thermal imager. The results showed high temporal consistency with the thermocouple. The deviation from infrared thermography was less than 5%. The BDD-coated intelligent tool achieves in situ real-time cutting temperature monitoring. It exhibits excellent measurement performance and structural integrity. This design provides a novel approach for intelligent temperature sensing in metal cutting. It also promotes the development of intelligent cutting tools for smart manufacturing.