Microwave-photonic control of optically accessible spin defects in diamond
Paper details
Section titled “Paper details”| Field | Value |
|---|---|
| Journal | Applied Physics Letters |
| Published | 2026-08-03 |
| Authors | Mohammad Reefaz Rahman, Ryan C Goldsmith, Karsten Schnier, Benjamin J. Lawrie, Jason D. McKinney |
| DOI | 10.1063/5.0336858 |
| Citations | 1 |
A carrier-suppressed, intensity-modulated direct-detection RF-over-fiber link drove ensemble nitrogen-vacancy center ODMR in diamond. It reached a measured power-conversion efficiency of 3.42% at a recovered RF output of −5.5 dBm near 2.87 GHz. At −0.7 dBm near 2.90 GHz, the link produced ODMR contrast above 2.2% at 11.2 G. That contrast was comparable to coaxial delivery at a similar antenna-feedpoint power. The authors describe this as the first IMDD-based RFoF microwave link to drive ensemble NV-center ODMR.
RFoF architecture and power reference
Section titled “RFoF architecture and power reference”The RF source is separated from the sensing head in the RFoF chain. A continuous-wave 1310 nm laser enters a Mach-Zehnder electro-optic modulator, where an RF signal and DC bias intensity-modulate the optical carrier. The modulated light travels through an approximately 1.2 m single-mode fiber. A reverse-biased Thorlabs DX25HF photodiode recovers the tone through square-law detection. The recovered RF then drives the same microstrip antenna used for the coaxial tests.
Both delivery methods use the antenna feedpoint as the reference plane for ODMR comparisons. This lets the authors compare contrast and linewidth at similar delivered power. It also matters for cryogenic systems. In the intended cryogenic implementation, the photodiode sits inside the cryostat, so RF is recovered after the optical link rather than before a lossy coaxial run.
Diamond sample and ODMR setup
Section titled “Diamond sample and ODMR setup”The sample was a 5 × 5 mm², 300 µm-thick electronic-grade CVD single-crystal diamond from Thorlabs, labeled DNVB1. It was cut along the h100 axis and contained approximately 300 ppb NV centers. A continuous-wave 532 nm laser was focused through a 10× objective with NA 0.25 to an approximately 20 µm spot. The same objective collected 550 to 850 nm fluorescence onto a CCD.
Under 532 nm excitation, optical cycling polarizes the NV ground state into the ms = 0 state. Resonant microwave transfer to ms = ±1 increases nonradiative decay and lowers detected photoluminescence, producing ODMR contrast.
A flat nickel-plated neodymium magnet supplied fields from 8 to 36 G. A NIST-traceable gaussmeter verified the field at the sample. At 11.2 G along the sample normal, each NV axis made a 54.7° angle with the field. The antenna used a 1.6 mm FR-4 substrate, copper top layer, and ground plane. Its input impedance was about 50 Ω near 2.87 GHz, and S11 measurements confirmed coupling from 2.8 to 3.0 GHz.
The frequency sweep used 2 MHz steps. The authors averaged nine acquisitions for each microwave-on and microwave-off condition. Resonance minima defined transition frequencies, while Gaussian fits gave linewidths. Contrast was calculated from integrated microwave-off and microwave-on photoluminescence.
Photonic conversion and operating points
Section titled “Photonic conversion and operating points”Carrier suppression sets the EOM DC bias to its half-wave voltage. Square-law photodetection then produces RF tones at even harmonics of the drive frequency. The desired 2Ω component is strongest at Vp/Vπ = 3.054, the modulation depth targeted for the experiment. The photodiode responsivity was 0.43 A/W, and the recovered RF frequency was about 2.9 GHz.
The link metrics reference recovered RF to the photodiode output and RF input to the EOM. The ODMR comparison uses the antenna feedpoint.
| Link quantity | Lower-power point | Higher-power point |
|---|---|---|
| Recovered RF power | −5.5 dBm, 0.28 mW | −0.7 dBm, 0.85 mW |
| RF input to EOM | 25 dBm, 316.2 mW | 21 dBm, 125.9 mW |
| Optical power at photodiode | 1.63 mW | 6.59 mW |
| Power-conversion efficiency | 3.42% | 2.5% |
| Estimated local thermal load | 8.19 mW | 34.1 mW |
Table I rounds the lower-point power-conversion efficiency to 3.4%.
Direct comparison with coaxial delivery
Section titled “Direct comparison with coaxial delivery”Conventional coaxial spectra were measured from 0 to 25 dBm at the antenna feedpoint. Contrast rose from about 1.8% at 0 dBm to about 10% at 25 dBm. The FWHM increased from about 7 MHz to about 14 MHz. Stronger driving increased population transfer but also produced power broadening and driving-induced dephasing.
The RFoF contrast rose from about 0.8% at −5.5 dBm to about 2.5% at −0.7 dBm. At −0.7 dBm, the RFoF result was comparable to the coaxial result at 0 dBm. The ODMR response was therefore governed mainly by power delivered to the antenna-NV system.
Across RFoF’s narrower power range, the FWHM remained near 6.7 to 7.3 MHz within ±0.7 MHz fitting uncertainty. The data did not show the linewidth increase seen at the coaxial high-power endpoint.
Zeeman response across magnetic fields
Section titled “Zeeman response across magnetic fields”At the −5.5 dBm operating point, the spectra followed Zeeman splitting as the field increased from 8 to 36 G. Contrast remained between 0.6% and 0.9%. The lowest-field trace had resonance centers at 2.858 and 2.884 GHz, a 26 MHz separation. The first-order estimate was 23.8 MHz for a local field of 7.37 G.
The authors attribute the small difference to local-field uncertainty, alignment error, and finite ensemble linewidths. The sweep confirms that the optical link preserves field-dependent ODMR structure.
Conversion efficiency and sensing-head load
Section titled “Conversion efficiency and sensing-head load”At −5.5 dBm, optical-to-RF efficiency was 17.3%, and RF-to-RF conversion gain was 0.089%. At −0.7 dBm, those values were 12.9% and 0.676%. Power-conversion efficiency divides recovered RF power by optical power at the photodiode plus its DC bias power. The lower efficiency at the higher-output point reflects its larger optical and bias inputs.
The estimated sensing-head load was 8.19 mW at the lower point and 34.1 mW at the higher point. It was estimated as optical power at the photodiode plus DC bias power. For an order-of-magnitude cable comparison, the authors considered a commercial semirigid cable with 6 to 14 dB/m insertion loss from 1 to 5 GHz. A representative 10 dB/m near 3 GHz gives 20 dB attenuation over 2 m.
Delivering −0.7 dBm through that cable would dissipate about 84 mW, compared with 34 mW for RFoF. This estimate excludes conductive heat leakage through the coax. Its thermal conductivity of about 4 × 10⁻³ W/cm K was identified as a barrier to scalable cryogenic use.
Table I also compares the link with a 1550 nm optical-heterodyne MUTC photodiode from prior work. That device reached 4.9% PCE and 4.9% optical-to-RF efficiency. Wavelength, detector, responsivity, and generation method differed, so the comparison provides a reference scale rather than a controlled test.
What remains untested
Section titled “What remains untested”The measurements stayed at room temperature and near the 2.87 GHz zero-field splitting. Cryogenic operation, high-field spin transitions, and operation at order 100 GHz were proposed but not tested. The RFoF power sweep was also narrower than the coaxial sweep, so the experiment did not establish RFoF performance at the 25 dBm coaxial endpoint.
The 1310 nm carrier lies within a low-loss telecommunications window and uses mature fiber, modulator, and photodiode technologies. The authors expect favorable 1310 nm photodiode responsivity at cryogenic temperatures, citing earlier detector studies rather than measuring it here.
For device engineering, the result establishes a separate microwave-delivery route that preserves the ODMR signature. It does not establish higher contrast than coaxial delivery. Comparisons should use antenna-feedpoint power because the source architectures have different losses. The paper also identifies a detector tradeoff between the higher bandwidth of biased devices and the reduced power consumption of unbiased devices.
Materials and support
Section titled “Materials and support”The paper requires a 5 × 5 mm², 300 µm-thick single-crystal CVD diamond sensing plate with an h100 cut and approximately 300 ppb NV centers. 6CCVD’s diamond materials catalog includes single-crystal MPCVD plates and wafers up to 125 mm, with thickness from 0.1 to 500 µm for single-crystal material, which covers the demonstrated format but does not state an NV concentration. engineering support is the relevant contact for translating the defect-density and orientation requirements into a sample specification.
View Original Abstract
A growing variety of optically accessible spin qubits have emerged in recent years as key components for quantum sensors, computers, and memories. However, the scalability of conventional spin-based quantum architectures remains limited by direct microwave delivery, which introduces thermal noise, electromagnetic crosstalk, and design constraints for cryogenic, high-field, and distributed systems. In this work, we present a unified framework for RF-over-fiber (RFoF) control of spins accessible through optically detected magnetic resonance (ODMR) spectroscopy of nitrogen-vacancy (NV) centers in diamond. The RFoF platform relies on an intensity-modulated 1310 nm laser carrying microwave signals over fiber and a high-speed photodiode for optical-to-electrical conversion to drive NV spin transitions. We report an RFoF power-conversion efficiency of 3.42% for an RF output PRF,out=−5.5 dBm at 2.87 GHz, enabling clear resolution of Zeeman splitting in proportion to an applied magnetic field. The RFoF architecture provides a path toward low-noise, thermally isolated, and cryo-compatible ODMR systems at sub-THz frequencies, thus bridging conventional spin-based quantum sensing protocols with emerging distributed quantum technologies.
Single Crystal Cvd Diamond Plate
View Specs →
Customized Single Crystal Cvd Diamond Plate
View Specs →
Electronic Grade Intrinsic Diamond Epitaxial Wafer H Terminated Superior 100 Mosfet Ready Substrate
View Specs →References we cover
Section titled “References we cover”- Scanning nitrogen-vacancy magnetometry down to 350 mK
- Realization of a multinode quantum network of remote solid-state qubits
- Demonstration of NV-detected ESR spectroscopy at 115 GHz and 4.2 T
- Sensitivity optimization for NV-diamond magnetometry
- Broadband, large-area microwave antenna for optically detected magnetic resonance of nitrogen-vacancy centers in diamond
Original source
Section titled “Original source”References
Section titled “References”- 2013 - The nitrogen-vacancy colour centre in diamond [Crossref]
- 2018 - Material platforms for spin-based photonic quantum technologies [Crossref]
- 2021 - Quantum guidelines for solid-state spin defects [Crossref]
- 2025 - Nanoscale magnetic ordering dynamics in a high curie temperature ferromagnet [Crossref]
- 2023 - Optically active spin defects in few-layer thick hexagonal boron nitride [Crossref]
- 2024 - Sensing spin wave excitations by spin defects in few-layer-thick hexagonal boron nitride [Crossref]
- 2021 - Spin defects in hBN as promising temperature, pressure and magnetic field quantum sensors [Crossref]
- 2026 - Defect engineering in large-scale CVD-grown hexagonal boron nitride: Formation, spectroscopy, and spin relaxation dynamics [Crossref]
- 2019 - Quantum nanophotonics with group IV defects in diamond [Crossref]