Skip to content

Rotating Magnetic Field-Assisted Vertical Sanding Electroplating Process for Diamond Wire

FieldValue
JournalMetals
Published2026-10-13
AuthorsTao Gong, Jiahao Liu, Jingang Liu, Junhao Hu, Zhuangzhi Li
DOI10.3390/met16101133

A φ0.23 mm electroplated diamond wire made by rotating magnetic field-assisted vertical sanding averaged 275.80 torsion cycles, 175.80% above the 100-cycle industry minimum. Its average breaking force was 80.03 N, 14.33% above the 70 N minimum. The circumferential bias rate was 81.54%, and the abnormal low-value occurrence rate was below 5%.

The study compared all three processes under identical conditions on the same 16-wire pilot line. Fifteen specimens were tested per process group for mechanical properties. RMF denotes rotating magnetic field.

IndicatorStandardHorizontal sandingOrdinary vertical sandingRMF-assisted vertical sanding
Post-dressing diameter, µm230 ± 10228.48230.01236.91
Mean bias rate, %Not stated90.9083.7581.54
Diameter fluctuation, µm≤20171514
Abrasive density, head/tail, grains/mm10 to 4519.51 / 19.3918.32 / 18.4017.89 / 17.85
Breaking force, head/tail, N≥7072.22 / 76.0373.70 / 73.4179.93 / 80.13
Torsion cycles, head/tail, r≥100210.00 / 214.86228.50 / 225.64273.36 / 278.23
Abnormal low-value rate, %Not stated10 to 156 to 8<5

RMF-assisted vertical sanding produced the lowest mean bias rate and axial diameter fluctuation. Horizontal sanding carried the most abrasive grains, averaging 19.45 grains/mm. RMF-assisted vertical sanding averaged 17.87 grains/mm. The authors argue that enriched grains on the horizontal wire were often stacked ineffectively, so its higher count gave lower grain utilization. The authors therefore treat circumferential uniformity as more important than abrasive count alone.

Pre-treatment used alkaline washing at 60 to 65 g/L, 55 ± 3 °C, and pH of at least 8. Activation used 7 to 7.5% sulfuric acid with a Baumé degree of 7 to 9. The authors selected this mild sequence to remove oil and oxides without damaging core strength. The core was φ0.23 mm high-carbon steel with a diameter tolerance of ±0.002 mm. High-strength crushed diamond powder had D10 of at least 24 µm, D50 of 36 ± 1 µm, and D90 of at most 52 µm. Roundness was 0.80 to 0.90, and flaky grains were limited to 5% or less.

Bath parameterSandingThickening
Ni(NH₂SO₃)₂, g/L615 to 620615 to 620
H₃BO₃, g/L38 to 3939 to 40
NiCl₂, g/L19 to 20.519 to 20.5
Temperature, °C55 ± 355 ± 3
pH3.8 to 4.13.8 to 4.0
Current, A1.6 ± 0.0334.9 ± 0.4

The rotating field operated at 0.6 T at the generator’s end face, 120 rpm, and 2.0 Hz throughout the experiments. Bottom-to-top wire travel placed gravity parallel to the wire path. The authors associate this arrangement with reduced one-sided settling and continuous bath renewal. The rotating field produced magnetohydrodynamic micro-convection through Lorentz forces on charged bath species. They state that this motion disperses agglomerates, breaks the electrode diffusion boundary layer, and accelerates nickel ion transfer. Their mechanism links the increased transfer to faster nickel nucleation and finer coating grains. Direct nickel nucleation on activated steel replaced the thin pre-plating layer. The authors report that the coating still formed a metallurgical bond with the steel. Removing pre-plating shortened the production line by 10%. Post-treatment used cold and hot washes at 22 ± 2 °C and 62 ± 3 °C. Drying and stress relief used 160 ± 5 °C for 12 h. Sharpening and rewinding used 20 ± 1 N and a 240 m/min line speed.

The line separated motion control from process control in a dual-PLC architecture. The motion PLC coordinated 86 servo axes through EtherCAT for constant line speed and tension. The control cycle was below 1 ms, with distributed clock synchronization across 16 wires. The two PLCs exchanged data through Modbus TCP, while field devices used Modbus RTU. Temperature control accuracy was ±3 °C, and current control accuracy was ±1%. A composite coil-diameter algorithm combined fixed-length initialization with real-time speed-ratio correction. Tension control combined main-speed feedforward with PID correction from dancer arm position. Wire-break detection monitored dancer movement and could trigger a warning and shutdown. The process PLC controlled heating, current, stirring, liquid level, sand feeding, and replenishment.

Before dressing, the rotating magnetic field wire measured 246.81 µm at the head and 246.64 µm at the tail. The head-to-tail difference was below 0.50 µm. Wire diameter sampling used an external micrometer at ten positions spaced every 0.5 m, with two perpendicular readings per position. A 50 m laser profile gave 14 µm of diameter fluctuation, the lowest among the three processes. Abrasive density averaged 17.87 grains/mm, within the standard interval of 10 to 45 grains/mm. The photomicroscope measured density at 150× with observation points spaced every 0.5 m along the wire. Bias rate came from coating thicknesses at N azimuthal positions measured by scanning electron microscopy. Mean bias decreased from 90.90% for horizontal sanding to 83.75% for ordinary vertical sanding. The magnetic-assisted process reached 81.54%. The authors attribute the small head-to-tail differences to mild bath concentration and flow-field changes.

Head breaking force was 79.93 ± 0.82 N, and tail force was 80.13 ± 0.62 N. Head torsion was 273.36 ± 22.27 r, and tail torsion was 278.23 ± 29.01 r. At the head, breaking force was 10.67% above horizontal sanding and 8.45% above ordinary vertical sanding. At the tail, the corresponding gains were 5.39% and 9.15%. Head torsion was 30.17% above horizontal and 19.63% above ordinary vertical sanding. Tail torsion was 29.49% above horizontal and 23.30% above ordinary vertical sanding. Tensile testing followed JB/T 12543-2026, used a 10 mm/min crosshead speed, and recorded maximum force until fracture. The reported coil value was the lower result from two specimens. Torsion testing followed GB/T 239.1-2012/2023 with a gauge length of 200d, approximately 46 mm. Each 360° turn counted as one cycle. The abnormal low-value rate fell below 5%, from 10% to 15% for horizontal and 6% to 8% for ordinary vertical. The authors interpret this rate as a measure of occasional weak coating and abrasive shedding. They credit stress relief at 160 °C with reducing hydrogen embrittlement and residual stress. Uniform abrasive wrapping and finer nickel grains were presented as complementary causes of the mechanical gains.

The results apply to a φ0.23 mm wire made on a 16-wire pilot line with fixed field settings. The study did not report a machining trial, so cutting life and cut quality remain unmeasured. That gap matters because the paper links abrasive segregation to eccentric wear and cutting-surface inclination. The authors did not vary field strength, rotation speed, or frequency. They state that the quantitative relation between magnetic parameters and coating properties is outside the study’s scope. Future work proposes a wider wire-diameter range, quantitative magnetic-field optimization, and intelligent closed-loop control. Until those tests are reported, 0.6 T, 120 rpm, and 2.0 Hz is the only demonstrated magnetic setpoint. The proposed transport and grain-refinement mechanisms were not independently quantified. For engineers, bias rate, axial fluctuation, torsion life, and low-value occurrence are more useful acceptance criteria than abrasive count alone. The paper positions the wire for slicing photovoltaic silicon, semiconductor wafers, sapphire, and engineering ceramics. Manufacturers should verify cutting life and surface inclination before transferring the reported performance to those applications.

View Original Abstract

For coarse-diameter electroplated diamond wires, the traditional horizontal sanding process suffers from inhomogeneous circumferential abrasive distribution, a lengthy manufacturing process, and poor production consistency. To address these issues, a pre-plating-free one-step electroplating process based on rotating magnetic field-assisted vertical sanding is proposed. Through the construction of a high-precision multi-process cooperative control system based on a dual-PLC architecture, systematic optimization of the process parameters from pre-treatment and electrodeposition to post-treatment is realized. Combined with the magnetohydrodynamic (MHD) and electrodeposition kinetic theories, the regulation mechanism of the rotating magnetic field-induced micro-convection effect on the mass transfer of the plating bath, particle dispersion, and grain refinement is revealed, and the kinetic principle by which the bottom-to-top vertical wire-running mode improves the circumferential deposition uniformity of abrasive grains on coarse-diameter wires is clarified. The experimental results show that the breaking force and the number of torsion cycles of the prepared diamond wire under the optimized process conditions are increased by 14.33% and 175.80%, respectively, and the properties of the head and tail ends of the wire exhibit high consistency. This study provides theoretical support for the industrial production of high-quality, high-consistency coarse-diameter diamond wires.