Development of human hand phantom containing radiophotoluminescence material
At a Glance
Section titled âAt a Glanceâ| Metadata | Details |
|---|---|
| Publication Date | 2015-12-15 |
| Journal | Radiation Measurements |
| Authors | Fuminobu Sato, Tatsuro Maekawa, Tomoki Sakiyama, Naoki Zushi, Kikuo Shimizu |
| Institutions | The University of Osaka |
| Citations | 10 |
Abstract
Section titled âAbstractâA radiophotoluminescence (RPL) material with high radiation sensitivity was made of polyurethane resin, silver-activated metaphosphate glass particles, and hollow glass microspheres. The density was adjusted to be 1.1 g/cm3 by controlling the amount of hollow glass microspheres. The response to high-energy photons over 100 keV was similar to that of the tissue-equivalent material (polymethylmethacrylate) because the two electron densities were similar. The RPL response had satisfactory linearity in the dose range from 10 to 6 Ă 104 mGy. An RPL scanner for three-dimensional (3-D) dose measurement was composed of an XYZθ motorized stage, a UV pulse laser, a gated photomultiplier tube (PMT), a red-laser displacement sensor, and an integrating ammeter. The surface profile was measured by the red-laser-displacement sensor. The UV laser was used as an excitation source, and the RPL responses were effectively detected with the gated PMT. An RPL material hand phantom was fabricated to understand the extremity dosimetry of a radiation workerâs hand. The hand phantom was exposed to X-rays, and its surface dose profile was obtained by the RPL scanner. Subsequently, the hand phantom was sliced into dozens of square plates using a diamond wire saw. Each inner dose profile was obtained with the RPL scanner. The inner dose profiles were roughly consistent with the computational simulation results. These results indicated that RPL imaging of the hand phantom was useful to understand extremity dosimetry.
Tech Support
Section titled âTech SupportâOriginal Source
Section titled âOriginal SourceâReferences
Section titled âReferencesâ- 2008 - Three-dimensional dose verification for intensity-modulated radiation therapy in the radiological physics centre head-and neck phantom using optical computed tomography scans of ferrous xylenol-orange gel dosimeters [Crossref]
- 2011 - Investigation of radiation exposure of medical staff: measurements supported by simulations with an articulated hand phantom [Crossref]
- 2011 - Simulation of beta radiator handling procedures in nuclear medicine by means of a movable hand phantom [Crossref]
- 2014 - Development of anthropomorphic hand phantoms for personal dosimetry in 90Y-zevalin preparation and patient delivering [Crossref]
- 2013 - Medical staff extremity dosimetry in CT fluoroscopy: an anthropomorphic hand voxel phantom study [Crossref]
- 2008 - AÂ compact system for RPL measurement of radiophotoluminescence of phosphate glass dosimeter [Crossref]
- 2013 - Photon dosimetry methods outside the target volume in radiation therapy: optically stimulated luminescence (OSL), thermoluminescence (TL) and radiophotoluminescence (RPL) dosimetry
- 2012 - AÂ novel disk-type X-ray area imaging detector using radiophotoluminescence in silver-activated phosphate glass [Crossref]
- 2014 - AÂ comparative study of optical and radiative characteristics of X-ray-induced luminescent defects in Ag-doped glass and LiF thin films and their applications in 2-D imaging [Crossref]
- 2011 - Radiation characteristics of homemade radiophotoluminescent glass dosimeter [Crossref]