Skip to content

Ultrafast dynamics of photoexcited free carriers in CVD diamonds

MetadataDetails
Publication Date2017-06-01
JournalJournal of Physics Conference Series
AuthorsXiangming Liu, Ben Zhang, Quanjie Zhong, Xiaoshi Peng, Shenye Liu
InstitutionsChina Academy of Engineering Physics
Citations2
AnalysisFull AI Review Included
  • Core Investigation: Ultrafast dynamics of photoexcited free carriers in bulk polycrystalline and single-crystal CVD diamonds measured using a phase-object (PO) pump-probe technique under UV excitation.
  • Critical Application Context: Research targeting Inertial Confinement Fusion (ICF) diagnostic windows, where high-intensity drive lasers and laser plasma-induced X-rays modify diamond optical properties, introducing phase and amplitude uncertainty in probe beams.
  • Nonlinear Optical Signature: A positive Kerr effect was observed in both PCD and SCD, confirming the dominance of ultrafast bound-electron nonlinear refraction over free-carrier contributions at femtosecond timescales.
  • Carrier Lifetime Differentiation: Two distinct transmittance recovery components were resolved: a fast decay (sub-picosecond, attributed to carrier-phonon scattering) and a slow decay (several hundred picoseconds, attributed to recombination via traps/impurities).
  • Comparative Material Performance: Single-crystal diamond exhibited significantly slower free-carrier relaxation dynamics than polycrystalline diamond, directly correlated with grain-boundary-enhanced carrier scattering in PCD.
  • Key Methodological Advancement: Use of a femtosecond UV source (190 fs, 515 nm fundamental via OPA) and a transparent dielectric disc phase object enabled simultaneous measurement of nonlinear refraction and absorption coefficients.
ParameterValueUnitContext
Pump WavelengthUV (via OPA from 515 nm fundamental)nmExcitation source for interband transitions
Probe Wavelength515nmFundamental Yb:KGW output
Pulse Duration190fsFWHM of femtosecond laser
Repetition Rate20HzLow rate to avoid cumulative thermal loading
Pump Fluence Range0.47 - 4.5mJ/cm²Variable fluence for nonlinear absorption studies
Pump-Probe TechniquePO (Phase Object) pump-probe—Modified Z-scan enabling simultaneous measurement
Diamond TypePolycrystalline CVD (PCD) & Single-Crystal CVD (SCD)—High-purity, bulk samples
Diamond SupplierElement Six, UK—Commercial CVD source
Sample TypeBulk (thick window geometry)—Suitable for ICF laser diagnostic windows
Nonlinear Refraction SignPositive (Kerr, n₂ > 0)—Confirmed via closed-aperture PO measurements
Fast Carrier DecaySub-picosecond (< 1 ps estimated from curve)psCarrier-phonon scattering dominated
Slow Carrier Decay~200-500 ps (curve-extracted)psTrap/impurity-assisted recombination
Transparency RangeUV to IRnmValidates broad optical window utility
Thermal ConductivityHigh (bulk diamond intrinsic)W/m·KCritical for high-average-power handling
  1. Sample Preparation: High-purity bulk PCD and SCD diamond samples prepared via chemical vapor deposition (Element Six UK), cut and polished for transmission optical measurements.
  2. Femtosecond Laser Source: Mode-locked Yb:KGW amplifier producing 515 nm, 190 fs pulses at 20 Hz repetition rate.
  3. Wavelength Conversion: Optical Parametric Amplification (OPA) system converts fundamental to UV pump beam for above-bandgap excitation.
  4. Beam Splitting: Output divided into pump and probe beams with independent delay-line control.
  5. Phase Object (PO) Insertion: Transparent dielectric disc on a glass plate introduced into the probe beam path for closed-aperture Z-scan-equivalent phase retrieval.
  6. Co-focusing: Pump and probe beams focused to the same point on the diamond sample.
  7. Detection Scheme: Differential transmittance measured simultaneously in open-aperture (nonlinear absorption) and closed-aperture (nonlinear refraction via PO) configurations.
  8. Variable Fluence Sweep: Pump fluence varied from ~0.47 to ~4.5 mJ/cm² to resolve intensity-dependent carrier dynamics and separate fast/slow recombination channels.
  9. Data Extraction: Fast and slow temporal components fitted to extract free-carrier lifetimes per diamond morphology.

This study demonstrates an immediate, high-value application for high-purity CVD diamond in high-energy laser diagnostics and ICF target chamber windows, where sub-picosecond transient characterization of free-carrier response directly defines measurement uncertainty. Below is a direct mapping from research requirements to our production capabilities.

Research RequirementApplicable 6CCVD MaterialKey Property Matched
Bulk PCD with sub-ps carrier responseOptical-Grade PCD PlateSubstrate thicknesses up to 10 mm; < 5 nm Ra polish available
Bulk SCD with slow carrier decay (low trap density)Optical-Grade SCD WaferUltra-low defect density; Ra < 1 nm polish; 0.1-500 µm thickness options
Broad UV-IR transparency windowsSCD or PCD optical windowsDiamond’s intrinsic 225 nm - far IR transmission
High thermal shock resistance under UV drive lasersSCD plate (high thermal conductivity)Mitigates thermal lensing in ICF diagnostic chains

For researchers seeking to replicate or extend this work, the following stock configurations align directly with the experiment geometry:

  • Optical-Grade SCD: Ideal for the single-crystal arm of this study. Our SCD wafers and plates (up to 125 mm and beyond for PCD) deliver the low grain-boundary density needed to observe extended carrier lifetimes.
  • Optical-Grade PCD (PCD Plate): Recommended for the polycrystalline comparator. Grain-boundary scattering engineered into PCD morphology accelerates carrier relaxation — useful as a tunable baseline.
  • Heavy Boron-Doped PCD (BDD): Available for follow-on studies where intentional carrier injection is required to disentangle trap-mediated pathways from intrinsic recombination.

The paper relies on a fixed commercial substrate geometry. Researchers advancing this work typically require:

  • Custom Thickness: We supply SCD and PCD from 0.1 µm to 500 µm freestanding films, plus thick diamond substrates up to 10 mm — enabling transmission experiments across orders of magnitude in optical path length.
  • Custom Aperture / Geometry: In-house laser cutting allows non-standard shapes, oriented facets, or thin-strip geometries for pump-probe sample mounting without cladding-induced artifacts.
  • Custom Metallization: For hybrid optoelectronic or electro-optic sample holder configurations, we offer Au, Pt, Pd, Ti, W, and Cu metallization — supporting integrated electrode geometries, heat-spreader attachment, or in-situ biasing.
  • Surface Engineering: Sub-nanometer (SCD) and sub-5 nm (PCD) polishing directly addresses surface recombination losses that can confound transient absorption measurements.

Free-carrier dynamics experiments in diamond are exquisitely sensitive to defect chemistry, isotopic purity (¹²C enrichment), and grain morphology. 6CCVD’s in-house PhD engineering team can collaborate on:

  • Material Selection: Matching SCD vs. PCD vs. BDD morphologies to specific UV pump-fluence regimes and target carrier lifetimes.
  • Stack Design: Anti-reflection coating guidance, wedged-window design for etalon suppression, and metallized carrier-injection contact schemes.
  • Diagnostic Geometry Optimization: Sample dimensioning for specific focusing geometries and cryogenic/vacuum chamber integration.

For custom specifications, specialty morphologies, or material consultation on ultrafast diamond optics and ICF window projects, visit 6ccvd.com or contact our engineering team directly.

View Original Abstract

We report on the experimental studies of the free-carrier dynamics and nonlinear optical properties in both bulk polycrystalline and single-crystal chemical vapor deposition (CVD) diamonds. The dynamics of nonlinear refraction and nonlinear absorption is measured by use of a time-resolved femtosecond pump-probe technique under UV excitation. Nonlinear refraction dynamics indicates a positive Kerr effect. Slow and fast components in nonlinear absorption transmittance are separated and used to determine the free-carrier lifetimes.