Skip to content

All-Diamond Microfiber Electrodes for Neurochemical Analysis

MetadataDetails
Publication Date2018-01-01
JournalJournal of The Electrochemical Society
AuthorsCory A. Rusinek, Yue Guo, Robert Rechenberg, Michael Becker, Erin K. Purcell
InstitutionsMichigan State University, University of North Carolina at Chapel Hill
Citations31
AnalysisFull AI Review Included
  • Rusinek et al. demonstrated a freestanding, all-diamond microfiber electrode comprising a conductive boron-doped polycrystalline diamond (BDD) core encapsulated by electrically insulating polycrystalline diamond (PCD).
  • The PCD cladding provides a biocompatible, hermetic, pinhole-resistant package while electrically isolating the conductive BDD core and reducing signal cross-talk.
  • The microfiber was fabricated through a batch-compatible sequence of microwave plasma-assisted chemical vapor deposition (MPACVD), titanium/copper masking, plasma etching, selective diamond regrowth, and silicon substrate release.
  • The reported fiber measured 25 µm wide × 6 µm high, with a 3 mm-long shank and an exposed conductive surface area of approximately 70 µm2.
  • The device exhibited an approximately 5.0 V potential window in pH 7.4 phosphate-buffered saline and a calculated double-layer capacitance of approximately 11 µF cm−2.
  • The electrode produced well-resolved dopamine signals by fast-scan cyclic voltammetry (FSCV) at 400 V/s, demonstrating suitability for rapid neurochemical measurements.
  • The work indicates a route toward hundreds or potentially thousands of reproducible, metal-free diamond microelectrodes for neuroscience, neurochemical sensing, and related biomedical electrochemistry.
ParameterValueUnitContext
Electrode architectureBDD core / insulating PCD cladding—Conductive BDD core fully enclosed except at the sensing tip and contact pad
Overall fiber width25µmReported overall cross-sectional probe width
Overall fiber height6µmReported overall cross-sectional probe height
Fiber shank length3mmMeasured from fiber base to sensing tip
BDD sensing surface area~70µm2Approximate exposed conductive BDD area
BDD layer thickness3.7µmConductive core layer
First insulating PCD layer thickness1.9µmLower PCD layer
Final insulating PCD layer thickness1.3µmUpper cladding layer
BDD resistivity1 × 10−3Ω·cmElectrical resistivity of the conductive BDD layer
Diamond crystal size1-2µmApproximate BDD and PCD crystallite size
Silicon substrate thickness1mmInitial growth substrate
Silicon wafer diameter3inch(100)-oriented silicon wafer
Growth reactor frequency2.45GHzMPACVD system
Growth pressure25TorrApplied during diamond deposition
Absorbed microwave power1.6kWApplied during diamond deposition
Deposition temperature700°CResulting substrate/deposition temperature
Methane concentration1%CH4 in hydrogen balance
Hydrogen flow balanceBalance—Carrier gas for high-quality microcrystalline diamond growth
Diborane concentration20,000ppmB/C ratio used to obtain conductive BDD
Copper hard-mask thickness1.2µmThermally evaporated masking layer
Titanium adhesion-layer thickness50nmTi interlayer between Cu mask and BDD
Copper etchant composition1:2vol/volFeCl3 solution:DI water
Diamond plasma-etch gases0.8:6:20sccmSF6/Ar/O2 flow ratio
Diamond plasma-etch microwave power750WApplied during reactive-ion plasma etching
Diamond plasma-etch bias160VSubstrate bias during etching
Diamond plasma-etch pressure15mTorrEtching pressure
Silicon release etchant55:15:30—HNO3/HF/H2O volume ratio
Electrochemical preconditioning medium1.0 M H2SO4—Preconditioning electrolyte
Preconditioning voltage range−2.4 to +3.0VCyclic-voltammetry conditioning range
PBS concentration1X—Final electrochemical test medium
PBS pH7.4—Physiological pH
PBS monobasic potassium phosphate1.1mMFinal 1X PBS composition
PBS sodium chloride155mMFinal 1X PBS composition
PBS dibasic sodium phosphate3.0mMFinal 1X PBS composition
BDD counter-electrode diameter2mmFreestanding BDD disk counter electrode
Potential window in PBS~5.0VAnalytical electrochemical window
Double-layer capacitance11µF cm−2Calculated using the SEM-derived electrode area
Redox-probe concentration2.5mMFe(CN)63−/4−, Ru(NH3)62+/3+, and hydroquinone
Redox-probe scan rate0.1V/sScan rate used for redox characterization
Fe(CN)63−/4− sensitivity1.1 ± 0.3nA mM−1Average of five individual BDD fibers
Fe(CN)63−/4− test concentrations1.0 and 2.5mMReproducibility assessment
Dopamine concentration, conventional CV100µMpH 7.4 PBS test
Conventional CV scan-rate range0.05-50V/sDopamine characterization
Steady-state dopamine response limitUp to 5.0V/sTransition toward diffusion-limited peaks above this rate
FSCV dopamine concentration20µMStagnant-cell feasibility test
FSCV scan rate400V/sRapid dopamine measurement
Dopamine oxidation peak~+1.05VReported peak versus Ag/AgCl reference
FSCV response time targetMillisecondmsRelevant to transient in vivo dopamine sensing
Reported scale-up potentialHundreds to thousandsElectrodes per batchWafer-level and batch-compatible process
  1. Prepare the multilayer diamond structure

    • Grow an insulating PCD layer and a conductive BDD layer on a 1 mm-thick, 3-inch, (100)-oriented silicon wafer.
    • Use separate dedicated 2.45 GHz MPACVD reactors or equivalent growth configurations.
    • Maintain a pressure of 25 Torr, absorbed microwave power of 1.6 kW, and deposition temperature of approximately 700 °C.
    • Use 1% methane in hydrogen for high-quality microcrystalline diamond growth.
    • Add diborane at a B/C ratio of 20,000 ppm for the conductive BDD layer.
  2. Pattern the conductive and insulating diamond layers

    • Thermally evaporate a 1.2 µm copper hard mask.
    • Deposit a 50 nm titanium adhesion layer between the copper and BDD.
    • Pattern the copper using diluted FeCl3 solution prepared at a 1:2 volume ratio with DI water.
    • Pattern the titanium by dry etching.
    • Etch the exposed diamond using a 0.8:6:20 sccm SF6/Ar/O2 plasma at 750 W, 160 V bias, and 15 mTorr.
    • Avoid over-etching the silicon because the final surface condition affects the subsequent selective diamond growth.
  3. Add the final insulating diamond cladding

    • Apply a 50 nm Ti/1.2 µm Cu mask by lift-off to protect the top of the BDD contact pads.
    • Grow the final insulating MCD layer using the same general MPACVD conditions as the initial diamond layers.
    • Limit growth to the exposed diamond regions to form the upper PCD encapsulation.
    • Verify that the final layer is electrically insulating and that the sensing tip and contact pad remain conductive.
  4. Release the freestanding microfibers

    • Remove the silicon substrate using HNO3/HF/H2O at a 55:15:30 volume ratio.
    • Rinse and manually separate the released fibers.
    • Cleave the anchor from the fiber shank with a sharp blade to expose pristine BDD at the contact or analysis region.
    • Rinse the resulting fibers with acetone and methanol before electrochemical testing.
  5. Electrochemically precondition the electrodes

    • Precondition each fiber in 1.0 M H2SO4.
    • Cycle the potential from −2.4 V to +3.0 V using cyclic voltammetry before analytical measurements.
  6. Characterize electrochemical behavior

    • Perform measurements in a Faraday cage using three-electrode or two-electrode configurations.
    • Use Ag/AgCl as the reference electrode and a freestanding 2 mm BDD disk as the counter electrode where applicable.
    • Measure potential window, background current, double-layer capacitance, and redox responses.
    • Test Fe(CN)63−/4−, Ru(NH3)62+/3+, and hydroquinone to assess electron-transfer and diffusion behavior.
  7. Demonstrate dopamine sensing

    • Use conventional cyclic voltammetry at scan rates from 0.05 to 50 V/s.
    • Determine the transition from steady-state response to semi-infinite linear diffusion behavior.
    • Perform FSCV in a stagnant electrochemical cell at 400 V/s using 20 µM dopamine.
    • Confirm that the oxidation and reduction features remain quantifiable at the high scan rate.
6CCVD materialRecommended role in this applicationTechnical relevance
Conductive boron-doped PCDBDD microfiber core or conductive electrode layerProvides the low-resistivity electrochemically active region required for dopamine and redox-probe detection
Insulating PCDCladding, dielectric barrier, and hermetic encapsulationIsolates the BDD core, suppresses signal cross-talk, and improves compatibility with biological environments
Optical Grade SCDOptional alternative for single-crystal electrode structuresMay be considered where reduced grain boundaries, tailored surface termination, or a single-crystal electrochemical interface is required
Polycrystalline diamondStructural and insulating platformSuitable for wafer-scale deposition, microfabrication, and controlled layer stacking
Boron-doped PCD with controlled dopant concentrationOptimized conductive coreEnables adjustment of conductivity, electrochemical response, and FSCV signal magnitude

Recommended material architecture: a heavily boron-doped PCD core surrounded by high-quality insulating PCD. The conductive core should be specified for low resistivity and stable electrochemical response, while the cladding should be optimized for continuity, low leakage, and biological compatibility.

  • The paper’s architecture can be translated into a custom PCD/BDD/PCD multilayer stack using controlled MPACVD growth and patterning.
  • 6CCVD can support customization of:
    • Conductive-layer thickness and boron concentration.
    • Insulating-cladding thickness and total fiber height.
    • Fiber width, shank length, tip geometry, and exposed sensing area.
    • Wafer diameter, layer layout, contact-pad design, and array configuration.
    • Surface termination and electrochemical conditioning requirements.
    • Ti, Pt, Pd, W, Cu, or Au metallization where an external connection or packaging interface is needed.
  • Although the reported all-diamond device is designed to avoid conventional metal exposure at the sensing interface, 6CCVD’s internal metallization capability can be used for:
    • Contact-pad metallization.
    • PCB or package attachment.
    • Hybrid or array-format devices.
    • Electrical interconnect and mechanical support structures.
  • 6CCVD’s capabilities extend to plates and wafers up to 125 mm for PCD, with SCD and PCD thickness ranges of 0.1-500 µm and substrates up to 10 mm.
  • The paper’s use of a patterned freestanding architecture is compatible with custom laser cutting, dicing, and subsequent separation of individual fibers or arrays. The final release and assembly process should be qualified together because the aggressive silicon etch and manual anchor-removal steps can affect yield.
  • 6CCVD’s in-house PhD team can assist with material selection for all-diamond neurochemical microelectrodes, including:
    • Defining the required B/C ratio and resulting resistivity.
    • Selecting PCD versus SCD for the cladding and sensing interface.
    • Balancing conductivity against film stress, adhesion, and microfabrication yield.
    • Designing the PCD/BDD/PCD layer stack for the target exposed area and FSCV response.
    • Establishing cleaning, preconditioning, and electrochemical validation protocols.
  • Engineering support can also address:
    • Hermeticity and leakage testing of the PCD cladding.
    • Dopant uniformity across the conductive core.
    • Surface morphology and crystal-size control.
    • Signal cross-talk and electrochemical noise.
    • Compatibility with Ag/AgCl reference electrodes, PBS electrolytes, and dopamine testing.
    • Scale-up from individual laboratory fibers to wafer-level arrays and packaged devices.
  • For implantable or chronic neural-interfacing projects, 6CCVD can provide diamond material development and electrode-grade processing support. Biocompatibility, sterilization, packaging, electrical safety, and regulatory validation remain application-specific qualification responsibilities.
Development stage6CCVD recommendationTarget outcome
Material screeningCompare PCD and SCD cladding options with controlled BDD core resistivityIdentify the best conductivity, stability, and surface-response balance
Layer-stack optimizationSpecify BDD and PCD thicknesses independentlyControl exposed area, current response, and dielectric isolation
Surface developmentTune morphology, termination, and cleaning protocolImprove reproducibility and reduce fouling-related signal drift
Device fabricationDevelop wafer-level patterning and release flowProduce multiple fibers or arrays from a common deposition and patterning run
Electrode integrationUse Ti/Cu or other custom metallization at contact pads and package interfacesProvide reliable electrical and mechanical attachment without exposing metal at the sensing region
FSCV validationTest dopamine and redox probes at progressively higher scan ratesEstablish usable limits for rapid neurochemical sensing
Scale-upTransfer the process to larger PCD wafers and array layoutsImprove device-to-device consistency and manufacturing throughput

For custom specifications or material consultation, visit 6ccvd.com or contact our engineering team directly.

View Original Abstract

Neurochemical sensing with implantable microelectrodes has created multiple research opportunities in the field of neuroscience. The ability to record extracellular biopotentials and detect neurotransmitters with high sensitivity has enabled deeper understanding of brain and nervous system function. Diamond has many advantages over other electrode materials such as good biocompatibility, wide potential window, low double-layer capacitance, long-term stability, resistance to corrosion/fouling, and fabrication flexibility. In this work, we present a micromachined, implantable, all-diamond microfiber capable of reliable, precise neurochemical sensing. The all-diamond fiber consists of a conductive boron-doped polycrystalline diamond (BDD) core encapsulated in layers of insulating polycrystalline diamond (PCD) cladding. The PCD serves as a biocompatible and hermetic package while also acting as a dielectric barrier to prevent signal cross-talking. The all-diamond microelectrodes were thoroughly characterized using topographical and electrochemical methods. The capability for neurotransmitter sensing was completed using dopamine (DA) as the model analyte. Fast-scan cyclic voltammetry (FSCV) of DA was also completed to demonstrate the practicality for in vivo sensing at rapid rates. The fabrication is described in great detail and the capability for batch-scale process is demonstrated. These novel all-diamond microelectrodes have commercial-scale potential, generating a powerful tool for neurochemical analysis.