Skip to content

An X-ray diamond focuser based on an array of three-component elements

MetadataDetails
Publication Date2018-01-01
JournalComputer Optics
AuthorsAnton G. Nalimov, IPSI RAS – Branch of the FSRC “Crystallography and Photonics” RAS, Victor V. Kotlyar, IPSI RAS – Branch of the FSRC “Crystallography and Photonics” RAS, T. V. Kononenko
AnalysisFull AI Review Included
  • Novel X-Ray Focuser Design: Numerical modeling of a compound refractive lens (CRL) consisting of three components (one central + two side cavities) fabricated in a thin diamond plate for focusing hard X-rays at 9.25 keV (λ = 0.134 nm).
  • Superior Focusing Performance: An array of 20 three-component elements achieves a focal spot FWHM of 57 nm, dramatically outperforming traditional round cylindrical lenses (0.22 µm FWHM) and delivering ~13× higher peak intensity (593 rel. units vs. 44.5 rel. units).
  • Material Advantage: Diamond’s refractive index ratio (δ/β ≈ 1000 at 10 keV) combined with high thermal conductivity, low thermal expansion, and chemical inertness makes it the optimal choice for high-intensity X-ray beams compared to beryllium or polymers.
  • Manufacturing Compatibility: The three-component Fresnel-like geometry minimizes sharp internal angles, reducing fabrication errors inherent in femtosecond laser ablation (typical corner radius ~10 µm).
  • Scalability Validated: Proportional scaling simulations (aperture 2.5 µm → 80 µm) predict a linear increase in focal distance while maintaining 40-76% focusing efficiency.
  • Future Projection: Scaling input aperture to 1 mm should yield a ~1 µm focal spot—pushing toward sub-micron hard X-ray focusing for synchrotron and laboratory microscopy applications.
  • Method: Beam Propagation Method (BPM) via BeamPROP software, solving the paraxial Helmholtz equation for monochromatic wave propagation.
ParameterValueUnitContext
X-ray Photon Energy9.25keVTarget radiation for focusing
Wavelength (λ)0.134nmHard X-ray regime
Diamond Refractive Index (n)1 - 7.3×10-6 + 3×10-9i—Real/imaginary parts (δ/β ≈ 2433)
Refractive Index Ratio (δ/β)1000—At 10 keV (diamond vs. Be: 4000)
Max Fresnel Lens Height9.6µmCalculated for diamond at λ=0.134 nm
Single Lens Aperture30µmWidth of three-component element
Diamond Plate Thickness (h)2µmThinnest modeled configuration
Number of Elements in Array20—Stacked along optical axis Z
Focal Spot FWHM (X-axis)57nmThree-component array (best result)
Focal Spot FWHM (X) - Single Lens1.1µmSingle 8×40 µm lens
Focal Spot FWHM (X) - 20 Round Lenses0.22µmReference comparison
Focal Spot FWHM (Y)0.931µmWaveguide effect in thin film
Peak Intensity (Imax)593rel. units20 three-component lenses
Peak Intensity - Round Lens Array44.5rel. unitsPerformance baseline
Effective Focal Distance (fe)27.5µmSingle 8×40 µm three-component lens
Focusing Efficiency (η)40-76%Across 2.5-80 µm aperture range
Lateral Corner Radius Limit~10µmFemtosecond laser ablation constraint
BPM Compute Time~30hours2× Xeon E5-2699 v4 mesh
Min. Lens Plate Thickness (mechanical)>100µmPractical handling threshold
  1. Simulation Tool: BeamPROP software implementing the Beam Propagation Method (BPM) — paraxial solution to the Helmholtz equation for monochromatic waves.
  2. Optical Configuration: Each lens element comprises one central oval cavity plus two near-triangular side cavities; symmetric across the X-axis to minimize sharp corners.
  3. Phase Delay Engineering: Modified Fresnel lens profile ensures correct phase accumulation for focusing at the target distance; central cavity is angle-free.
  4. Reference Benchmark: Single cylindrical round hole (D = 10 µm) compared directly to the three-component design at matched dimensions.
  5. Array Assembly: 20 elements stacked consecutively along the optical Z-axis to enhance numerical aperture and intensity gain.
  6. Scaling Study: Proportional dimensional scaling across all three axes (D: 2.5 µm → 80 µm, h: 0.5 µm → 16 µm) to predict performance at practical aperture sizes.
  7. Manufacturing Route: Femtosecond laser ablation / precision laser cutting to produce through-holes with vertical walls in diamond membranes.
  8. Diffraction Effect Mitigation: Thinned profile along the optical axis (≈13.5% shorter than continuous-relief lens) reduces absorption losses at lens edges.

This research demonstrates the strategic value of ultra-thin, free-standing diamond membranes with precisely engineered through-hole geometries for next-generation X-ray optics. The requirements map directly onto our core competencies.

  • Optical-Grade Polycrystalline Diamond (PCD) Membrane: The paper explicitly references PCD films (2 µm thickness) manufactured via CVD methods. 6CCVD supplies PCD plates/wafers up to 125 mm diameter with thickness control from 0.1 µm to 500 µm — covering the modeled 2 µm regime and the practical >100 µm regime needed for mechanical robustness.
  • Single Crystal Diamond (SCD): For experiments demanding lower bulk absorption and superior phase coherence, our SCD wafers (0.1 µm - 500 µm) deliver the exceptional crystalline quality required for next-generation synchrotron optics.
  • Boron-Doped Diamond (BDD): Not directly required for this passive optical application, but available for complementary X-ray detection or beam diagnostic integration.
  • Precision Laser Cutting: The paper’s three-component geometry demands sharp internal corners below 10 µm radius. Our in-house laser micromachining services can deliver custom through-hole profiles in both PCD and SCD membranes with the dimensional precision required for Fresnel-type X-ray lenses.
  • Wafer-Scale Processing: While the paper models apertures up to 1 mm, our PCD capability extends to 125 mm wafers, enabling large-format lens arrays or mosaic lens architectures for synchrotron beamlines.
  • Ultra-Thin Membrane Supply: 6CCVD routinely delivers freestanding diamond membranes down to 0.1 µm thickness for transmission optics, X-ray windows, and MEMS applications.
  • Surface Engineering: Our polishing capability (Ra < 5 nm for inch-size PCD, Ra < 1 nm for SCD) ensures minimal scatter loss and optimal phase-front fidelity for refractive X-ray optics.
  • Custom Metalization: Should the research evolve into hybrid optoelectronic X-ray devices (e.g., integrated beam monitors), we offer Au, Pt, Pd, Ti, W, and Cu metalization in-house.

Our in-house PhD engineering team specializes in diamond material selection for extreme-environment optics. For X-ray focusing projects—whether replicating the three-component Fresnel geometry, scaling to 1 mm apertures, or designing novel compound refractive lens arrays—our engineers can advise on:

  • Optimal PCD vs. SCD selection for given photon energy and aperture requirements
  • Membrane thickness trade-offs between transmission efficiency and mechanical stability
  • Laser-cut geometry tolerance analysis for minimizing corner-rounding artifacts
  • Integration paths for beamline-compatible mounting and beam delivery systems

For custom diamond specifications, ultra-thin membrane fabrication, or material consultation on your X-ray optics project, visit 6ccvd.com or contact our engineering team directly. We ship globally (DDU default, DDP available) and support both prototype and production volumes.

View Original Abstract

The use of a compound refractive lens fabricated of a thin diamond plate is considered for focusing hard 9.25 keV X-rays. Each element of the diamond lens consists of a central cavity and two side cavities in the diamond plate. It is shown numerically that an array of 20 such elements is able to produce a focal spot of width FWHM = 57 nm. The lens aperture size is 30 µm and the diamond plate thickness is 2 mkm. The simulation shows that by proportionally increasing the dimensions of the lenses on all three axes, bringing the input pupil size to 1 µm, the X-ray focal spot width can be increased to 1 µm using the same lens array.