Charge-state dynamics during excitation and depletion of the nitrogen-vacancy center in diamond
At a Glance
Section titled “At a Glance”| Metadata | Details |
|---|---|
| Publication Date | 2018-06-13 |
| Journal | Physical Review A |
| Authors | Luke Hacquebard, Lilian Childress |
| Institutions | McGill University |
| Citations | 63 |
| Analysis | Full AI Review Included |
Executive Summary
Section titled “Executive Summary”- Core Value Proposition: Quantifies charge-state dynamics (ionization & recombination) of single Nitrogen-Vacancy (NV) centers in diamond under picosecond pulsed illumination, establishing a predictive linear rate-equation model for optimizing quantum optics protocols.
- Key Achievement: Extraction of relative rates for optical excitation, stimulated emission, ionization, and recombination under 531 nm (green) and 766 nm (red) illumination, including out of metastable singlet states.
- Maximum Theoretical Efficiency: Identifies an “ideal” excitation-stimulated emission cycle limit of 82.5 ± 0.3% probability, with red illumination causing 93.3 ± 0.2% stimulated emission vs 6.6 ± 0.2% ionization at saturating powers.
- Methodology: Uses single-shot charge state preparation and readout with 594 nm yellow light, combined with ps-pulsed 531 nm/766 nm lasers to isolate intrinsic dynamics from long-timescale spin/metastable effects.
- Application Impact: Directly applicable to Stimulated Emission Depletion (STED) nanoscopy, spin-to-charge conversion protocols, laser threshold magnetometry, and quantum information gates.
- Material Dependency: Relies on high-purity, low-nitrogen chemical-vapor-deposition (CVD) bulk diamond with specific crystallographic orientation (<111>) and ultra-low fluorescence background for single NV isolation.
- Charge Readout Fidelity: Achieves 91-97% charge state discrimination fidelity using yellow excitation photon counting statistics.
Technical Specifications
Section titled “Technical Specifications”| Parameter | Value | Unit | Context / Application |
|---|---|---|---|
| Green Excitation Wavelength | 531 | nm | Pulsed laser for NV− excitation |
| Yellow Charge Readout Wavelength | 594 | nm | CW HeNe for charge state initialization/detection |
| Red Depletion Wavelength | 766 | nm | Pulsed laser for stimulated emission / STED |
| Green Pulse Width | < 100 | ps | PicoQuant LDH-FA pulsed diode |
| Red Pulse Width | < 100 | ps | PicoQuant LDH-FA pulsed diode |
| Pulse Repetition Rate | 1 | MHz | Single-pulse regime isolation |
| Pulse Pair Separation | 592 ± 2 | ps | Green-red paired excitation |
| Min Pulse Separation Step | 12.5 | ns | Limited by 80 MHz driver oscillator |
| CW Green Initialization | ~250 | µW | 2 µs duration, fixes initial charge state |
| CW Yellow Readout Power | 2 | µW | 4 ms duration, high-fidelity charge readout |
| Optimum Green Average Power | 153-158 | µW | Maximizes excited-state population |
| Max Tested Red Average Power | 350 | µW | Saturating stimulated emission condition |
| NV− Excited State Lifetime | 12.2 ± 0.1 | ns | ms = 0 spin state |
| NV0 Excited State Lifetime | 18 ± 3 | ns | Literature overlap value |
| Relative Green-Induced Ionization Rate (a) | 3.7 ± 0.6 | % of G | NV− → NV0 |
| Relative Green-Induced Recombination Rate (b) | 8 ± 1 | % of G | NV0 → NV− |
| Relative NV0 Excitation Rate (c) | 130 ± 20 | % of G | NV0 ground state excitation |
| Ideal Cycle Probability | 82.5 ± 0.3 | % | Ground → Excited → Ground (no ionization) |
| Red-Induced Stimulated Emission (max) | 93.3 ± 0.2 | % | At saturating red power |
| Red-Induced Ionization (saturated) | 6.6 ± 0.2 | % | Competing process to STED |
| Charge Readout Fidelity | 91-97 | % | Threshold-based discrimination |
| Initial NV− Population | ~70 | % | After CW green initialization |
| Fluorescence Detection Window | 635-750 | nm | NV− zero-phonon-line region |
| Objective NA | 1.35 | — | Oil immersion, Olympus UPlanSApo 60x |
| FPGA Timing Resolution | 8.3 | ns | AOM/microwave gating |
| Diamond Crystal Orientation | <111> | — | Type IIa, CVD-grown (Sumitomo) |
Key Methodologies
Section titled “Key Methodologies”- Sample Preparation: High-purity, low-nitrogen type IIa CVD single-crystal diamond (<111> orientation) with individually addressable single NV centers.
- Confocal Microscopy: Homebuilt confocal microscope with 1.35 NA oil objective for single-NV isolation and addressing.
- Four-Laser Excitation Architecture:
- CW 532 nm (green): Spin/charge initialization.
- CW 594 nm (yellow): High-fidelity charge state preparation and readout.
- Pulsed 531 nm (green): Excitation of NV charge states.
- Pulsed 766 nm (red): Stimulated emission / depletion (STED).
- Pulse Gating: Acousto-optic modulators (AOMs) gate all laser sources with 8.3 ns resolution via FPGA control.
- Timing Control: PicoQuant PDL 828 (SEPIA II) laser driver enables variable pulse-pair separation (down to 592 ps).
- Pulse Sequence Protocol:
- CW green pre-pulse (2 µs, ~250 µW) for initialization.
- Yellow charge readout (4 ms, 2 µW) before and after pulsed experiment.
- Optional microwave π-pulses for spin-state preparation (ms = 0 vs ±1).
- Single ps-pulse or pulse-pair excitation (1 MHz repetition, 1 µs AOM window).
- Photon Counting: Time-correlated single photon counting (PicoHarp 300) for fluorescence lifetime and depletion analysis.
- Data Fitting: Simultaneous four-level rate-equation model fit across all three measurement types (charge switching, fluorescence, time-resolved depletion).
- Steady-State Comparison: 150 µs pulsed illumination sequences to compare with literature steady-state charge distributions.
6CCVD Solutions & Capabilities
Section titled “6CCVD Solutions & Capabilities”Applicable Materials
Section titled “Applicable Materials”To replicate or extend the single-NV charge dynamics research presented in this paper, 6CCVD recommends:
- Optical Grade Single Crystal Diamond (SCD): Type IIa, ultra-low nitrogen (<5 ppb) CVD-grown plates with <111> or <100> crystallographic orientations. Our SCD is ideal for hosting isolated NV centers with the long coherence times required for these charge-state switching experiments.
- Custom NV-Doped SCD: Controlled nitrogen incorporation during CVD growth for tailored NV density (single NV to ensemble regimes).
- High-Purity Polycrystalline Diamond (PCD): Alternative substrate option for ensemble measurements requiring larger active areas (up to 125 mm diameter).
Customization Potential
Section titled “Customization Potential”The authors utilized a Sumitomo CVD diamond with 20 µm copper wire soldered directly to the sample for microwave delivery. 6CCVD can replicate and enhance this configuration:
- Custom Metalization: In-house Ti/Pt/Au, Ti/W/Au, or Cu metalization available for ohmic contacts, microwave striplines, or coplanar waveguides directly deposited on diamond surfaces.
- Laser Cutting & Dicing: Precision shaping of bulk diamond substrates (up to 10 mm thickness) into custom geometries for cryogenic or microwave resonator integration.
- Surface Polishing: Ultra-low roughness (Ra < 1 nm for SCD, < 5 nm for inch-size PCD) to minimize fluorescence background and ensure high-fidelity single-NV addressing.
- Thickness Control: SCD and PCD membranes from 0.1 µm to 500 µm for thin-film cavity QED or open microcavity applications.
Engineering Support
Section titled “Engineering Support”The optimal operating regimes identified in this paper (158 µW green, 350 µW red, 82.5% cycle efficiency) require diamond substrates with precisely controlled nitrogen concentration, minimal crystal defects, and well-defined charge stability. 6CCVD’s in-house PhD engineering team can assist with:
- Material Selection Consultation: Matching NV density, crystal orientation, and purity to your specific quantum optics, STED nanoscopy, or spin-to-charge conversion application.
- Prototype Development: Rapid iteration on substrate dimensions, metalization patterns, and packaging for cryogenic or room-temperature quantum sensing platforms.
- Bulk-to-Thin-Film Conversion: Etching or polishing services to create diamond membranes suitable for nanophotonic integration.
Call to Action
Section titled “Call to Action”For custom specifications, material consultation, or to discuss how 6CCVD can support your NV-center quantum optics research, visit 6ccvd.com or contact our engineering team directly.
View Original Abstract
The charge-state dynamics of the nitrogen-vacancy (NV) center in diamond play a key role in a wide range of applications, yet remain imperfectly understood. Using single picosecond pulses and pulse pairs, we quantitatively investigate the charge dynamics associated with excitation and fluorescence depletion of a single NV center. Our pulsed excitation approach permits significant modeling simplifications and allows us to extract relative rates of excitation, stimulated emission, ionization, and recombination under 531 and 766 nm illumination. By varying the duration between paired pulses, we can also investigate ionization and recombination out of metastable states. Our results are directly applicable to experiments employing stimulated emission-depletion imaging and can be used to predict optimal operating regimes where excitation and stimulated emission are maximized relative to charge-state-switching processes.