A study of the radiation tolerance of poly-crystalline and single-crystalline CVD diamond to 800 MeV and 24 GeV protons
At a Glance
Section titled “At a Glance”| Metadata | Details |
|---|---|
| Publication Date | 2019-08-01 |
| Journal | Journal of Physics D Applied Physics |
| Authors | L. Bäni, Andreas V. Alexopoulos, M. Artuso, F. Bachmair, M. Bartosik |
| Institutions | Istituto Nazionale di Fisica Nucleare, Sezione di Lecce, University of Bonn |
| Citations | 20 |
| Analysis | Full AI Review Included |
Executive Summary
Section titled “Executive Summary”- Radiation Hardness Validation: This study by the RD42 Collaboration at CERN quantifies the radiation tolerance of polycrystalline (pCVD) and single-crystalline (scCVD) diamond detectors subjected to high-energy proton irradiation (800 MeV and 24 GeV).
- Damage Constant Benchmark: The paper establishes that both pCVD and scCVD diamond share an identical radiation damage mechanism, with measured damage constants of
1.04 × 10⁻¹⁸ cm²(p·µm)⁻¹(800 MeV) and0.62 × 10⁻¹⁸ cm²(p·µm)⁻¹(24 GeV). - Charge Collection Stability: Initial charge collection distances (ccd) ranged from
218 µm to 466 µmacross 4 µm to 5 µm thick samples, demonstrating high baseline material quality before irradiation up to1.80 × 10¹⁶ p·cm⁻². - Detector Architecture: A 50 µm pitch strip detector with 25 µm strip widths was fabricated using photolithography, Cr/Au metalization (500 Å / 2000 Å), and annealed at 400 °C in N₂.
- Uniformity Evolution: pCVD material becomes progressively more uniform with increasing fluence (standard deviation drops from 0.394 to 0.112), while scCVD maintains constant uniformity (σ ≈ 0.064).
- Operational Reliability: Diamond detectors demonstrate sustained performance for high-luminosity collider environments, validating CVD diamond for beam monitoring in ATLAS, CMS, LHCb, and future HL-LHC upgrades.
Technical Specifications
Section titled “Technical Specifications”| Parameter | Value | Unit | Context |
|---|---|---|---|
| Diamond Types | pCVD, scCVD | — | Detector-grade CVD material |
| Sample Thickness (pCVD) | 510 - 516 | µm | 800 MeV irradiation group |
| Sample Thickness (scCVD) | 395 - 466 | µm | 800 MeV / 24 GeV groups |
| Sample Area (pCVD) | 10 × 10 | mm² | Large-area polycrystalline |
| Sample Area (scCVD) | 5 × 5 | mm² | Limited by single-crystal growth |
| Strip Pitch | 50 | µm | Photolithographic patterning |
| Strip Width | 25 | µm | Readout electrode |
| Strip Count | 32 / 64 | channels | Per detector device |
| Bias Electrode Metalization | 500 Å Cr / 2000 Å Au | Å | Sputter-deposited |
| Annealing Temperature | 400 | °C | 4 minutes in N₂ atmosphere |
| Electric Field (Operating) | ±1 to ±2 | V·µm⁻¹ | Bias voltage range ±400 V to ±1100 V |
| Initial ccd (pCVD) | 218 - 241 | µm | Charge collection distance |
| Initial ccd (scCVD) | 395 - 466 | µm | Near-full charge collection |
| Electron-Hole Pairs | 3600 | e⁻-h⁺ / 100 µm | Minimum ionizing particle |
| Damage Constant (800 MeV) | 1.04 × 10⁻¹⁸ | cm²(p·µm)⁻¹ | Combined pCVD + scCVD |
| Damage Constant (24 GeV) | 0.62 × 10⁻¹⁸ | cm²(p·µm)⁻¹ | Combined pCVD + scCVD |
| Max Fluence (800 MeV) | 1.34 × 10¹⁶ | p·cm⁻² | Sample 4 |
| Max Fluence (24 GeV) | 1.80 × 10¹⁶ | p·cm⁻² | Sample 5 |
| Telescope Intrinsic Resolution | 1.8 | µm | Silicon strip reference planes |
| Track Position Uncertainty | 1.3 | µm | After χ² selection |
| CMC Noise Range | 73.2 - 86.6 | e⁻ ENC | VA2.2 readout, 1.8 µs peaking |
| Total Noise Range | 92.2 - 138.6 | e⁻ ENC | Pre-CMC, all channels |
| e⁻-h⁺ Schubweg Ratio (λₕ/λₑ) | ~1.3 | — | Mobility-lifetime assumption |
Key Methodologies
Section titled “Key Methodologies”-
Sample Preparation:
- CVD diamond substrates prepared with Cr/Au metalization via photolithographic lift-off.
- Devices annealed at 400 °C for 4 minutes in N₂ atmosphere to reduce surface states.
- Bias side attached via silver paint to ceramic hybrid with RC filter network.
-
Irradiation Protocol:
- 800 MeV protons: Los Alamos LANSCE Blue Room facility, fluence tracked via ²²Na activity in aluminum activation foils.
- 24 GeV protons: CERN IRRAD facility on T8 beamline (PS East Hall), fluence quantified via secondary emission chambers (SEC) and aluminum foil activation.
-
Strip Detector Fabrication:
- 25 µm wide strips with 25 µm gaps produced via photolithographic patterning.
- Guard ring structure at strip potential to suppress edge/surface leakage currents.
- VA2.2 ASIC readout with 1.8 µs peaking time, wire-bonded strip-by-strip.
-
Test Beam Characterization:
- 120 GeV hadron beam at CERN with “Strasbourg” 8-plane silicon tracking telescope.
- Pre-test pumping with 54 MBq ⁹⁰Sr β-source for 4 hours to stabilize trap population.
- Voltage cycling: low field (±400-500 V) and high field (±800-1100 V) at both polarities.
-
Signal Analysis:
- Transparent analysis: 5 of 10 strips around predicted track position summed.
- Cluster analysis: seed strip >5σ CMC noise, adjacent strips >3σ.
- Common-mode correction algorithm reduces noise σ from 11.5 e⁻ to 2.6 e⁻.
-
Damage Model Fitting:
- Linear damage curve:
1/λ = 1/λ₀ + kᵢ × φ - λ derived from measured ccd via Schockley-Ramo theorem.
- λₕ/λₑ ratio varied 0.7-2.1 to bound systematic uncertainty.
- Linear damage curve:
6CCVD Solutions & Capabilities
Section titled “6CCVD Solutions & Capabilities”-
Applicable Materials:
- Optical Grade SCD (Single Crystal Diamond): Required for replicating the scCVD results in this study. 6CCVD provides SCD with ccd values approaching full thickness (>400 µm for 466 µm thick samples), matching the high-purity benchmark in this paper.
- Electronic Grade PCD (Polycrystalline Diamond): For pCVD detector fabrication at large areas. 6CCVD offers PCD plates up to 125 mm diameter with thicknesses from 0.1 µm to 500 µm, suitable for the 10 × 10 mm² strip detectors described.
- Boron-Doped Diamond (BDD): While not used in this study, 6CCVD’s BDD capability offers an alternative for applications requiring conductive diamond layers or specialized electrode configurations.
-
Customization Potential:
- Metalization: The Cr/Au (500 Å / 2000 Å) stack used in this study can be replicated or modified at 6CCVD’s in-house facility, with options for Ti, Pt, Pd, W, and Cu metallization schemes depending on interface engineering requirements.
- Dimensional Control: 6CCVD provides custom wafer dimensions up to 125 mm for PCD and laser cutting services to produce 5 × 5 mm² or 10 × 10 mm² die geometries, including precision strip patterning via photolithographic-compatible surface finishes.
- Thickness Precision: Both SCD and PCD available from 0.1 µm to 500 µm in the specified range, enabling optimization for charge collection distance (ccd) vs. signal yield trade-offs.
- Surface Polishing: For detector-grade devices requiring Ra < 1 nm (SCD) or < 5 nm (PCD), 6CCVD’s polishing services ensure the surface quality needed for uniform metalization and low leakage current under high bias.
-
Engineering Support:
- 6CCVD’s in-house PhD engineering team can assist with material selection for radiation-hard particle detector projects, including those targeting HL-LHC upgrade specifications (>10¹⁶ p·cm⁻² tolerance).
- Consultation available on optimizing λₕ/λₑ ratios through material purity enhancement, grain size control in PCD, and crystal quality verification in SCD.
- Support for strip/pixel detector geometry design, including metallization stack recommendations for specific bias voltage and annealing protocols.
- Guidance on charge collection distance benchmarking and damage constant characterization for custom detector geometries.
-
Call to Action: For custom specifications, detector-grade material consultation, or radiation-hardness engineering support for your particle physics, synchrotron, or beam monitoring applications, visit 6ccvd.com or contact our engineering team directly. Global shipping available (DDU default, DDP on request).
View Original Abstract
Abstract We have measured the radiation tolerance of poly-crystalline and single-crystalline diamonds grown by the chemical vapor deposition (CVD) process by measuring the charge collected before and after irradiation in a 50 m pitch strip detector fabricated on each diamond sample. We irradiated one group of sensors with 800 MeV protons, and a second group of sensors with 24 GeV protons, in steps, to protons cm−2 and protons cm−2 respectively. We observe the sum of mean drift paths for electrons and holes for both poly-crystalline CVD diamond and single-crystalline CVD diamond decreases with irradiation fluence from its initial value according to a simple damage curve characterized by a damage constant for each irradiation energy and the irradiation fluence. We find for each irradiation energy the damage constant, for poly-crystalline CVD diamond to be the same within statistical errors as the damage constant for single-crystalline CVD diamond. We find the damage constant for diamond irradiated with 24 GeV protons to be and the damage constant for diamond irradiated with 800 MeV protons to be . Moreover, we observe the pulse height decreases with fluence for poly-crystalline CVD material and within statistical errors does not change with fluence for single-crystalline CVD material for both 24 GeV proton irradiation and 800 MeV proton irradiation. Finally, we have measured the uniformity of each sample as a function of fluence and observed that for poly-crystalline CVD diamond the samples become more uniform with fluence while for single-crystalline CVD diamond the uniformity does not change with fluence.
Tech Support
Section titled “Tech Support”Original Source
Section titled “Original Source”References
Section titled “References”- 2002 - Development of radiation hard semiconductor: devices for very high luminosity colliders
- 2015 - High-luminosity Large Hadron Collider (HL-LHC): preliminary design report [Crossref]
- 2017 - High-luminosity Large Hadron Collider (HL-LHC): technical design report
- 1986 - Volume expansion of diamond during ion implantation [Crossref]
- 1992 - Displacement threshold energy for type IIa diamond [Crossref]
- 1994 - Development of diamond tracking detectors for high-luminosity experiments at the LHC
- 2017 - RD42 status report: development of diamond tracking detectors for high-luminosity experiments at the LHC
- 2018 - RD42 status report: development of diamond tracking detectors for high-luminosity experiments at the LHC and beyond
- 2005 - Charge-carrier properties in synthetic single-crystal diamond measured with the transient-current technique [Crossref]