  • Research focuses on high-pressure, high-temperature (HPHT) optical sensing of liquid-phase samples sealed within custom copper (Cu) cell mounts, utilizing single crystal diamond as an optical window.
  • The experimental optical train combines a mid-IR heating laser (λ ≈ 9.7 µm) with a visible probing laser (λ = 639 nm) to perform in-situ diagnostics inside a Cu pressure cell.
  • Optical isolation is achieved via a Faraday rotator and non-polarizing beam splitter, with detection routed through a band-pass filter to a photomultiplier tube (PMT) operating at room temperature (RT).
  • Diamond windows enable broadband optical access to chemically reactive or high-pressure environments while maintaining hermetic sealing via silicone gaskets and Cu screw caps.
  • Pressure/temperature regime implies diamond must withstand >1 GPa equivalent compressive stress and transient thermal gradients across a broad IR-to-visible transmission band.
  • The methodology is broadly applicable to studies of hydrogen storage materials, supercritical fluids, and geological fluid inclusion analogs.
  • Replication requires ultra-low absorption diamond windows (single crystal preferred) with engineered sealing surfaces and metallic coatings compatible with Cu-cell integration.

ParameterValueUnitContext
Heating laser wavelength (λ)9.7µmMid-IR CO2-class laser for sample excitation
Probing laser wavelength (λ)639nmVisible alignment & optical diagnostics
Optical isolator typeFaraday rotator—Prevents back-reflection into probing laser
Beam splitterNon-polarizing—50/50 throughput to sample and PMT detector
DetectorPhotomultiplier Tube (PMT)—Room-temperature (RT) operation
Optical filterBand-pass—Isolates probe signal from heating laser scatter
Heating spot dimensions4.5 × 4.5 × 0.5mmDefines sample illumination volume
Diffracted beam diameter (φ)32mmDefines required clear aperture of diamond window
Pressure cell materialOxygen-free Cu—High thermal conductivity, malleable gasket sealing
Sealing gasketSilicone—Rubber closure + silicone spacer, square cross-section
Window material (sample-side)Single crystal glass—Reference window for optical baseline
Window material (under test)Single crystal diamond—Broad-spectrum, high-pressure window
Mirror count in optical train7 (M1-M7)—Multi-pass geometry for signal collection
ModulatorAcousto-optic—Provides temporal gating of probing beam

  1. Cell Assembly: Mount sample inside Cu cell with silicone gasket, silicone spacer, and Cu cover plate; seal mechanically via Cu screw cap with square Cu plate compression.
  2. Optical Alignment: Route probing laser (λ = 639 nm) through optical isolator → non-polarizing beam splitter → Faraday cell, then introduce through single crystal glass window.
  3. Sample Excitation: Deliver mid-IR heating laser (λ = 9.7 µm) via dedicated optical path (M1-M5) into the Cu sample cell.
  4. Signal Collection: Capture diffracted beam (φ 32 mm) from sample region and route via M6, M7 to a band-pass filter.
  5. Detection: Filtered signal is directed to a room-temperature PMT for photon counting.
  6. AOM Gating: Acousto-optic modulator provides temporal modulation of the probe beam for lock-in or pulsed detection schemes.
  7. Pressure Containment: Cu cell geometry + silicone gasket stack provides hydrostatic seal at elevated temperature (typical HPHT fluid studies span 0.1-1 GPa, 300-800 K).
  8. Optical Reference: Single crystal glass window used as a parallel baseline for transmission / scattering comparisons against diamond.

Research RequirementRecommended 6CCVD MaterialRationale
Broad-spectrum IR-visible optical window under high pressureOptical-Grade Single Crystal Diamond (SCD)Lowest bulk absorption across 0.2-100 µm; withstands extreme compressive stress
Reactive / chemically aggressive sample environmentsHigh-Purity SCD (N<1 ppm, B<0.1 ppm)Chemically inert; no degradation from acids, organics, or supercritical CO2
Heated optical access (transient thermal load)SCD Ra < 1 nm polished windowsMinimizes scattering; stable under thermal cycling
Conductive / integrated window-electrode geometriesBoron-Doped Diamond (BDD)If electrical biasing or in-situ electrochemistry is added to the HPHT cell
  • Custom Aperture Geometry: The 32 mm diffracted beam diameter indicates a clear-aperture requirement that 6CCVD can satisfy via laser cutting of SCD plates up to 125 mm (PCD) and custom-shaped single-crystal pieces.
  • Metalization for Cu-Cell Brazing: For hermetic integration into the Cu screw-cap stack, 6CCVD provides in-house metallization with Ti / Pt / Au stacks or pure Cu / W layers suitable for diffusion bonding to oxygen-free Cu mounts.
  • Engineered Sealing Surfaces: Diamond windows can be polished to specified flatness/parallelism, and edges can be metallized to enable metal-gasket sealing instead of silicone (for higher pressure regimes).
  • Thickness Control: Choose window thickness from 0.1 µm to 500 µm to balance mechanical strength vs. optical transmission; thinner for transmission, thicker for >1 GPa load.

The described HPHT optical cell combines several non-trivial engineering challenges: sealing integrity, broadband optical access under load, and laser-induced heating. 6CCVD’s in-house PhD engineering team can assist with:

  • Material selection between SCD and PCD based on optical vs. mechanical priorities.
  • Optimization of diamond thickness and clear aperture for your specific pressure/temperature target.
  • Metallization stack design for integration with Cu, Ti, Au, Pt or refractory braze systems.
  • Surface polishing specifications (SCD: Ra < 1 nm; PCD up to inch-size: Ra < 5 nm) to minimize parasitic scattering at the band-pass filter wavelength.

For custom specifications, metallization options, or a material consultation on your high-pressure optical cell project, visit 6ccvd.com or contact our engineering team directly.