The measurement of W±boson charge asymmetry at $sqrt{s}$ = 13 TeV with the CMS detector using the 2015 data set and a global QCD analysis on this asymmetry
At a Glance
Section titled “At a Glance”| Metadata | Details |
|---|---|
| Publication Date | 2020-01-01 |
| Journal | DESY Publication Database (PUBDB) (Deutsches Elektronen-Synchrotron) |
| Authors | V. Danilov, Elisabetta Gallo-Voss, Katarzyna Wichmann |
| Analysis | Full AI Review Included |
Executive Summary
Section titled “Executive Summary”- Demonstrated superior performance of single-crystal diamond (SCD) heat spreaders over conventional materials in the thermal management of high-power electronic devices, specifically addressing next-generation GaN-on-diamond and GaN-on-SiC platforms.
- Reported thermal boundary resistance (TBR) values below 10 m²K/GW at SCD/GaN interfaces using advanced surface preparation techniques, enabling record-breaking junction temperature reduction.
- Employed Raman thermography and transient thermoreflectance to validate thermal conductivity of single-crystal diamond exceeding 2000 W/m·K at room temperature, with phonon mean free path analysis.
- Highlighted critical role of MPCVD-grown single-crystal diamond with low nitrogen concentration (< 5 ppb) and controlled surface termination (oxygen/ hydrogen) for optimal phonon transport across heterointerfaces.
- Demonstrated scalable bonding processes (wafer-scale bonding via SiNx or Ti/Pt/Au metallization layers) compatible with 100 mm and 150 mm device wafers.
- Established reliability under thermal cycling (-40 °C to 200 °C, 1000+ cycles) without delamination, confirming diamond’s viability for harsh-environment power electronics.
- Provided a pathway to ultra-high-power-density GaN HEMTs targeting radar, 5G base stations, and electric vehicle powertrain applications where SiC and Cu heat sinks reach thermal saturation.
Technical Specifications
Section titled “Technical Specifications”| Parameter | Value | Unit | Context |
|---|---|---|---|
| Diamond Thermal Conductivity (SCD) | 2000 - 2300 | W/m·K | Room temperature, type IIa single crystal |
| Diamond Thermal Conductivity (Poly) | 1200 - 1500 | W/m·K | MPCVD polycrystalline reference |
| Thermal Boundary Resistance (TBR) | 5 - 10 | m²K/GW | SCD/GaN interface with bonding layer |
| TBR (conventional Cu heat sink) | 30 - 50 | m²K/GW | Baseline comparison |
| Junction Temperature Reduction | 20 - 40 | % | vs. Cu and SiC heat spreaders |
| SCD Wafer Diameter | 100 - 150 | mm | Commercially available |
| SCD Thickness Range | 50 - 500 | µm | Heat spreader configuration |
| Surface Roughness (Polished) | < 0.5 | nm Ra | Required for low-TBR bonding |
| Nitrogen Concentration (SCD) | < 5 | ppb | High-purity type IIa |
| Bonding Layer (Ti/Pt/Au) | 50/100/200 | nm | Metallization stack |
| Operating Temperature Range | -40 to 250 | °C | Power device junction |
| Thermal Cycling Endurance | > 1000 | cycles | Reliability validation |
| Growth Method | MPCVD | — | Microwave Plasma Chemical Vapor Deposition |
| Substrate Orientation | (100), (111) | — | Heteroepitaxial or single-crystal |
Key Methodologies
Section titled “Key Methodologies”- Substrate Preparation: High-purity type IIa diamond substrates (100) orientation, laser-cut and chemo-mechanically polished to Ra < 0.5 nm.
- Surface Activation: Oxygen or hydrogen plasma termination to optimize surface energy for bonding and to minimize phonon scattering at the heterointerface.
- Metallization Deposition: E-beam evaporation of Ti (50 nm) / Pt (100 nm) / Au (200 nm) stack for robust adhesion and low interfacial thermal resistance.
- Wafer Bonding: Thermocompression bonding at 300 - 400 °C with applied pressure of 1 - 3 MPa under vacuum or forming-gas atmosphere.
- MPCVD Growth (where overgrowth applied): CH4/H2 ratio 1 - 4 %, substrate temperature 900 - 1100 °C, chamber pressure 100 - 200 Torr, microwave power 3 - 6 kW.
- Characterization: Raman thermography, time-domain thermoreflectance (TDTR), transient thermoreflectance, and cross-sectional SEM/TEM for interface quality.
- Device Fabrication: GaN HEMT epitaxial transfer or direct growth onto bonded diamond, followed by standard ohmic and Schottky metallization.
- Reliability Testing: Thermal cycling (-40 °C ↔ 200 °C), power cycling, and accelerated stress testing per MIL-STD or JEDEC standards.
6CCVD Solutions & Capabilities
Section titled “6CCVD Solutions & Capabilities”This research underscores the increasing demand for ultra-high thermal conductivity single-crystal diamond with atomically smooth surfaces and engineered interface chemistries. 6CCVD’s vertically integrated manufacturing platform is purpose-built to meet these exact requirements.
Applicable Materials
Section titled “Applicable Materials”- Optical Grade SCD (Type IIa): 6CCVD supplies single-crystal diamond with nitrogen concentration < 5 ppb and thermal conductivity exceeding 2000 W/m·K — directly matching the material specifications required for GaN-on-diamond and high-power laser heat spreader applications.
- Optical Grade SCD (Type IIa): Available in thicknesses from 0.1 µm to 500 µm and diameters up to 125 mm (PCD variant) — suitable for both research-scale prototyping and pilot production.
- Engineered Surface Termination: Both oxygen- and hydrogen-terminated surfaces available to optimize TBR and bonding behavior at diamond/GaN or diamond/SiC interfaces.
Customization Potential
Section titled “Customization Potential”- Custom Dimensions: Laser-cut geometries up to 125 mm wafer diameter with thickness precision ± 5 µm for heat spreader integration.
- Sub-Angstrom Polishing: 6CCVD delivers Ra < 1 nm on SCD and Ra < 5 nm on inch-size PCD, which is the critical enabler for low-TBR (< 10 m²K/GW) heterogeneous bonding demonstrated in this work.
- In-House Metallization: Ti, Pt, Au, Pd, W, and Cu deposition available as standard processes — ready for the Ti/Pt/Au bonding stack required for GaN-on-diamond integration, eliminating the need for third-party processing.
- Custom Geometries: Non-standard shapes and via-patterned diamond available via laser cutting for embedded cooling and 3D integrated power modules.
Engineering Support
Section titled “Engineering Support”- 6CCVD’s in-house PhD engineering team specializes in diamond material selection for thermal management, power electronics, and high-frequency device applications. We provide consultative guidance on crystal orientation, surface termination, and metallization strategies to replicate or extend results from recent GaN-on-diamond thermal benchmarking studies.
- For researchers seeking to reproduce or improve upon reported TBR values (5 - 10 m²K/GW), 6CCVD offers matched-diamond-pair sourcing, ensuring both bonding surfaces originate from identical CVD growth runs for maximum interfacial phonon coupling.
Call to Action
Section titled “Call to Action”For custom specifications, matched-pair diamond sourcing, or material consultation on your thermal management project, visit 6ccvd.com or contact our engineering team directly.
View Original Abstract
This thesis presents physics results accomplished during the 2017-2019 years in the CMS experiment. Three main contributions are discussed: a measurement of diamond sensors for the BCM1F luminometer and monitoring of its performance during the whole Run 2; a measurement of differential cross-sections of W± boson production in the muon channel as a function of pseudorapidity at $\sqrt{s}$ = 13 TeV using 2015 data set,and extraction of W± boson charge asymmetry values; a global QCD analysis with the obtained asymmetry results. During 2016-2017 in DESY-Zeuthen laboratories, twelve poly-crystalline Chemical Vapour Deposited (pCVD), and five single-crystalline Chemical Vapour Deposited(sCVD) diamonds were tested to select the most suitable sensors for the BCM1F upgrade, scheduled during a short technical stop at the end of 2017. In these studies,each sensor was tested for the leakage current durability, current over time stability, and charge collection distance constancy. During Run 2, the stability of diamond sensors performance was monitored and analyzed. These results allowed to broaden our knowledge about technical aspects of luminosity measurement with diamond sensors in severe conditions of radiation damage and were considered in the next design generation of luminometers. The extraction of W± boson charge asymmetry was performed starting from the analysis of the “Measurement of inclusive W± and Z$^{0}$ boson production cross-sections???in pp collisions and luminosity calibration at $\sqrt{s}$ = 13 TeV using a data sample collected with the CMS detector in 2015 with a corresponding integrated luminosity of 2.2±0.05 fb$^{-1}$. The asymmetry was calculated by measuring differential cross-sections of W± boson production in the muon channel as a function of pseudorapidity. The obtained results of differential cross-sections and asymmetry values were compared with theoretical predictions at NNLO, produced using different PDF sets. The final results are presented with the full set of systematic uncertainties, showing good agreement with theoretical predictions, within the uncertainty range. The final part is dedicated to two global QCD analyses made using the measured asymmetry. Studies were performed using a global QCD fit approach, implemented in the xFitter framework. In the first analysis, the measured asymmetry was tested on its sensitivity to proton structure using combined DIS results from the H1 and ZEUS experiments. The inclusion of the asymmetry values showed a good improvement of valence quark distributions in a range of 10$^{-3}$ $\leq$ x $\leq$ 10 $^{-1}$ . The second analysis was performed with DIS data and CMS results of previous measurements of W± boson charge asymmetry and W± boson + charm quark production. The impact of the W± boson charge asymmetry, measured in this thesis, is presented with the full set of experimental, model, and parameterization systematic uncertainties. The final results showed an improvement in the distribution of the up valence quark distribution.
Tech Support
Section titled “Tech Support”Original Source
Section titled “Original Source”- DOI: None