Proton radiation effects on carrier transport in diamond radiation detectors
At a Glance
Section titled “At a Glance”| Metadata | Details |
|---|---|
| Publication Date | 2020-02-01 |
| Journal | AIP Advances |
| Authors | Mengnan Zou, Jen Bohon, J. Smedley, J. R. Distel, K. Schmitt |
| Institutions | California Institute of Technology, Los Alamos National Laboratory |
| Citations | 17 |
| Analysis | Full AI Review Included |
Proton Radiation Effects on Carrier Transport in Diamond Radiation Detectors: Technical Analysis
Section titled “Proton Radiation Effects on Carrier Transport in Diamond Radiation Detectors: Technical Analysis”Executive Summary
Section titled “Executive Summary”- Core Achievement: Demonstrated the feasibility of single-crystal CVD (SCVD) diamond as a highly radiation-hardened material for next-generation proton flux monitoring in high-energy physics and medical dosimetry.
- Material Validation: Electronic grade SCVD diamond (N < 5 ppb) maintained operational stability under an 800 MeV proton beam at a high fluence rate of 6.25 × 109 p/cm2/s, confirming its use as a reliable relative flux monitor.
- Failure Threshold Identification: Established that ultra-high proton fluence rates (1 × 1011 p/cm2/s) cause permanent lattice displacement damage, acting as carrier traps that degrade Charge Collection Efficiency (CCE).
- Defect Mechanism: Identified that proton-induced vacancies preferentially trap holes, generating an internal electric field that retards electron collection efficiency—a key polarization phenomenon.
- Simulation Validation: Utilized FLUKA Monte Carlo simulation to accurately model Displacements Per Atom (DPA) profiles, matching experimental X-ray Beam-Induced Current (XBIC) data to predict radiation hardness limits.
- Practical Implication: Confirms that even after significant radiation damage, diamond detectors provide a linear response to incident X-ray flux, ensuring long-term utility in harsh radiation environments.
Technical Specifications
Section titled “Technical Specifications”| Parameter | Value | Unit | Context |
|---|---|---|---|
| Diamond Type | Electronic Grade SCVD | - | Single Crystal CVD, Nitrogen < 5 ppb |
| Detector Dimensions (PRT1_3) | 4 × 4 × 0.5 (500 µm thickness) | mm | Pt electrodes, 3 mm diameter circular pad |
| Detector Dimensions (PRT2_4) | 4 × 4 × 0.3 (300 µm thickness) | mm | Pt electrodes, 3 × 3 mm solid square pad |
| Electrode Material | Platinum (Pt) | - | Patterned via photolithography |
| Wire Bonding | 25 µm diameter Aluminum | µm | Signal collection |
| Proton Kinetic Energy | 800 | MeV | LANSCE facility, Los Alamos National Lab |
| Proton Frequency | 10 | Hz | Pulsed beam delivery |
| Ultra-High Fluence Rate | 1 × 1011 | p/cm2/s | Caused significant signal degradation |
| High Fluence Rate | 6.25 × 109 | p/cm2/s | Stable signal response observed |
| Total Fluence (PRT1_3) | 2.32 × 1014 | p/cm2 | Ultra-high rate exposure |
| Total Fluence (PRT2_4) | 1.54 × 1014 | p/cm2 | Combined high and ultra-high rate exposure |
| Beam Size (Run 1) | 25 | mm | Beam diameter (PRT1_3) |
| Beam Size (Run 2) | 9 | mm | Beam diameter (PRT2_4) |
| CCE Range (Pre-Irradiation) | 0.2 to 0.6 | - | Dependent on bias voltage |
| DPA Depth Profile | Rational function (first 50 µm) | - | Stable constant deeper in diamond |
| X-ray Flux Linearity | 10-7 to 103 | W | Linear response post-irradiation |
Key Methodologies
Section titled “Key Methodologies”- Detector Fabrication: Utilized commercial electronic grade SCVD diamond. Platinum electrodes were patterned via photolithography, with conductive epoxy used for circuit board mounting and Al wire bonding for signal extraction.
- Proton Irradiation Protocol: Detectors were aligned to the center of the 800 MeV proton beam at the LANSCE facility. A 0.6 m lead shutter controlled incident dose timing.
- Run 1 Configuration: Detector placed perpendicular to the incident beam. Four channels bonded together for unified signal collection under ultra-high fluence rate conditions.
- Run 2 Configuration: Detector placed parallel to the incident beam. Beam size reduced to 9 mm with sequential exposures: 10 min ultra-high rate, followed by post-damage evaluation at high rate.
- Real-Time Monitoring: Ion Beam-Induced Current (IBIC) measurements captured real-time current response to track immediate signal degradation.
- Post-Irradiation Characterization: X-ray Beam-Induced Current (XBIC) measurements mapped depth profiles and lateral CCE distributions using synchrotron radiation.
- Vacancy Modeling: FLUKA Monte Carlo simulation package calculated radiation-induced vacancy distributions along the beam path.
- DPA Calculation: Displacements Per Atom (DPA) modeled as a rational function of penetration depth (first 50 µm), reaching a stable constant at greater depths.
6CCVD Solutions & Capabilities
Section titled “6CCVD Solutions & Capabilities”- Applicable Materials: This research requires ultra-high-purity, low-nitrogen optical/electronic grade Single Crystal Diamond (SCD) to replicate carrier transport studies. 6CCVD provides premium SCD with controlled nitrogen concentration (< 5 ppb achievable), ensuring that intrinsic carrier behavior—not defect artifacts—dictates detector performance.
- Detector-Grade Specifications: The paper utilized 300 µm and 500 µm thicknesses. 6CCVD manufactures SCD films across a broad thickness range (0.1 µm to 500 µm), allowing precise tailoring for optimal proton stopping power and charge collection volume.
- Customization Potential: The research employed complex photolithography-patterned platinum (Pt) electrodes. 6CCVD offers in-house custom metallization (Au, Pt, Pd, Ti, W, Cu) and laser cutting services. Custom electrode geometries—including 3 mm circular pads, segmented channels, and cross-street patterns—can be fabricated to match specific detector designs.
- Wafer Format: While the paper used 4 × 4 mm samples, 6CCVD’s capability to produce larger PCD wafers (up to 125 mm) and custom-shaped SCD substrates provides flexibility for scaled detector arrays or stacked configurations as deployed in the LANL experiments.
- Engineering Support: 6CCVD’s in-house PhD engineering team specializes in material selection for harsh-environment radiation detection. We assist clients in matching diamond grade, thickness, and metallization to specific proton energy regimes, fluence expectations, and charge collection efficiency targets.
- Quality Assurance: For detector fabrication, surface preparation is critical. 6CCVD delivers SCD with surface roughness Ra < 1 nm, minimizing surface recombination losses that would otherwise compromise CCE measurements in XBIC characterization.
For custom specifications or material consultation, visit 6ccvd.com or contact our engineering team directly.
View Original Abstract
Diamond, a highly radiation-resistant material, is considered a nearly ideal material for radiation detection, particularly in high-energy physics. In this study, radiation damage from high-energy proton beams was induced in diamond crystals to determine exposure lifetime in detectors made from this material; the effects were investigated using non-destructive x-ray techniques and through the FLUKA simulation package. Two diamond detectors were irradiated by an 800 MeV proton beam at different fluence rates, and the real-time current response was recorded to observe degradation in the signal over time. It was determined that the proton fluence rate had a significant effect on the device degradation. The detector performance from the irradiated detectors was characterized using x-ray beam-induced current measurements, and the mechanism of proton radiation damage to diamond sensors, especially the radiation effects on carrier transport, was studied. The vacancies generated from proton irradiation were considered the major source of detector degradation by trapping holes and inducing an internal electric field. Simulation results from the FLUKA package revealed an uneven distribution of the radiation-induced vacancies along the beam path, and the corresponding detector signals calculated from the simulation results displayed a good match to the experimental results.
Tech Support
Section titled “Tech Support”Original Source
Section titled “Original Source”References
Section titled “References”- 1999 - Parameterisation of radiation effects on CVD diamond for proton irradiation [Crossref]