Skip to content

Effect of the position of parallelogram ribs in micro channel on heat transfer using diamond nanoparticles

MetadataDetails
Publication Date2020-09-25
JournalMetallurgical and Materials Engineering
AuthorsKamel Chadi, Nourredine Belghar, Mokhtar Falek, Zied Driss, Belhi Guerira
InstitutionsUniversity of Biskra, University of Sfax
Citations2
AnalysisFull AI Review Included
  • Core Objective: Numerical (CFD) investigation of rib placement and geometry inside silicon micro-channel heat sinks to maximize thermal dissipation for electronic cooling applications.
  • Coolant Innovation: Utilizes a 5% volume concentration diamond-water nanofluid, leveraging diamond’s exceptional thermal conductivity (≈ 1000 W/m·K) to enhance base fluid properties (water).
  • Geometric Variables: Three rib placement cases (parallelogram ribs) compared against a baseline rib-less micro-channel (Case 1), focusing on ribs offset along the z-axis (e.g., z = 6.67 mm from outlet).
  • Optimal Configuration: Case 2 (parallelogram ribs at 2/3L from the exit) yielded the highest Nusselt number (Nu), lowest thermal resistance, and most uniform temperature distribution across the heated bottom wall.
  • Fluid Dynamics Regime: Laminar, steady-state flow with Reynolds number (Re) between 200 and 400, corresponding to inlet velocities of 1.53 m/s to 3.01 m/s.
  • Key Trade-off Identified: While Case 2 maximized heat exchange, the friction factor and pressure drop increased with rib complexity—critical for pump-loop design considerations.
  • Validation: Numerical results benchmarked against experimental data from Chai et al., showing consistent Nu trends across Re = 200-800.
ParameterValueUnitContext
Nanoparticle TypeDiamond (C)—Solid phase of nanofluid
Nanoparticle Thermal Conductivity (ks)1000W/m·KMaxwell-Granetts effective medium model
Nanoparticle Density (ρs)3510kg/m3Property input for Brinkman viscosity model
Nanoparticle Specific Heat (Cp,s)516J/kg·KProperty input for Khanafer heat capacitance model
Base FluidWater (H2O)—Newtonian, incompressible carrier fluid
Volume Concentration (φ)5% (0.05)vol.%Diamond loading in water
Particle DiameterNot specified (assumed nanoscale)nmCritical for Brownian motion effects
Reynolds Number (Re)200 - 400—Laminar regime
Inlet Velocity (uin)1.53 - 3.01m/sSteady-state, uniform velocity profile
Bottom Wall Heat FluxConstant flux appliedW/m2Simulates electronic chip heat load
Top Wall ConditionAdiabatic—Insulated boundary
Channel MaterialSilicon (Si)—Micro-fabricated substrate
Working Fluid ModelsMaxwell-Granetts, Brinkman, Khanafer—knf, µnf, ρnf, Cp,nf
SoftwareANSYS-Fluent—Commercial CFD solver
Validation ReferenceChai et al. (2013)—Rectangular micro-channel, Re 200-800
Mesh Independence~600,000 nodesnodesConfirmed via grid convergence study
Maximum Bottom Wall Temperature~314KCase 1 (rib-less) baseline
Minimum Bottom Wall Temperature~302KCase 2 (optimal ribs at 2/3L)
Thermal Resistance Range~0.05 - 0.30K/WCase-dependent; lowest in Case 2
Fanning Friction Factor0.05 - 0.7—Decreases with increasing Re
  1. Geometry Definition: Construct four silicon micro-channel heat sink geometries in CFD preprocessor:
    • Case 1: Baseline, no ribs (reference).
    • Case 2: Parallelogram ribs positioned at 2/3L from the micro-channel exit.
    • Case 3: Ribs shifted toward inlet region.
    • Case 4: 13 parallelogram ribs relocated to one sidewall along z = 6.67 mm.
  2. Nanofluid Property Calculation: Compute effective thermophysical properties of the 5% diamond-water nanofluid using established correlations (Maxwell-Granetts for knf, Brinkman for µnf, mixing rule for ρnf, Khanafer for Cp,nf).
  3. Mesh Generation: Generate a high-density computational mesh (~600,000 nodes) and perform a grid independence study to ensure solution convergence.
  4. Boundary Condition Setup: Define inlet velocity (1.53-3.01 m/s), outlet gauge pressure (zero), no-slip walls, constant heat flux on the bottom wall, and adiabatic top wall.
  5. Solver Configuration: Run a steady-state, laminar, incompressible simulation in ANSYS-Fluent with fluid-solid interface continuity enforced for heat flux.
  6. Parametric Sweep: Vary Reynolds number (Re = 200, 250, 300, 350, 400) across all four geometry cases to evaluate thermal-hydraulic behavior.
  7. Post-Processing: Extract Nusselt number (Nu), Fanning friction factor, thermal resistance, and temperature contour plots for comparative analysis.
  8. Validation: Compare baseline (Case 1) results against published experimental data from Chai et al. to confirm numerical accuracy.

This research highlights the growing demand for high thermal conductivity materials integrated into microfluidic and electronic cooling architectures. The diamond-water nanofluid (5 vol%) demonstrated in this study relies on the extreme thermal conductivity of synthetic diamond particles—a material domain where 6CCVD holds deep expertise.

Applicable Materials

Paper Requirement6CCVD Recommended Product
High-k diamond nanoparticles (~1000 W/m·K) for nanofluid suspensionDetonation Nanodiamond Powder (or custom crushed MPCVD PCD fragments)
Silicon micro-channel substrate with enhanced heat spreadingOptical-Grade SCD Wafers (up to 125mm PCD plates) for heat spreader integration
Boron-doped diamond electrodes for advanced electrochemical cooling systemsHeavy Boron-Doped PCD (BDD-grade wafers)

Customization Potential

  • Diamond Particle Morphology: The paper assumes generic nanoscale diamond particles. For nanofluids requiring precise particle size distribution (e.g., 30-90 nm diameter as referenced in comparable CuO studies), 6CCVD can supply custom-graded nanodiamond or polycrystalline diamond fragments tailored for colloidal stability and thermal performance.
  • Micro-Channel Substrate Fabrication: While the study models silicon channels, transitioning to diamond-based heat spreaders or hybrid Si/diamond substrates can further reduce thermal resistance. 6CCVD provides SCD and PCD plates with sub-nanometer surface roughness (Ra < 1 nm SCD, < 5 nm PCD) ready for wafer bonding or thin-film deposition.
  • Metallization for Sensor/Heater Integration: If this cooling architecture is extended to include embedded temperature sensors, thin-film heaters, or electrodes, 6CCVD offers in-house metallization with Au, Pt, Pd, Ti, W, and Cu—compatible with standard semiconductor process flows.
  • Laser Cutting & Dicing: Custom channel geometries, rib profiles, or wafer-level micro-feature machining can be accommodated through 6CCVD’s precision laser cutting services.

Engineering Support

Replicating or extending this research—whether by fabricating diamond-enhanced micro-channel prototypes, characterizing nanodiamond suspension stability, or selecting the optimal SCD/PCD grade for your thermal management stack—requires a partner with deep materials expertise. 6CCVD’s in-house PhD engineering team specializes in MPCVD diamond synthesis and can assist with:

  • Material selection guidance for thermal management applications
  • Custom diamond morphology and doping specifications
  • Wafer dicing, polishing, and metallization process consultation
  • R&D collaboration on diamond-integrated microfluidic devices

Call to Action

For custom specifications, bulk nanodiamond orders, or material consultation for your next-generation electronic cooling project, visit 6ccvd.com or contact our engineering team directly.

View Original Abstract

In the present work, we have studied numerically three dimensions, the impact of the position of parallelogram ribs in a micro-channel on thermal exchange. In this study, we proposed three cases of micro-channel heat sinks with parallelogram ribs. As well as one case without ribs, in each of the three cases, we varied the parallelogram rib positions on the micro-channel. The main purpose of this study is to find the best position for parallelograms ribs in which the heat dissipation is useful for improving the thermal performance of the micro-channel as well as improving the cooling of electronic components. We have chosen silicon micro-channel drains for four cases. Constant heat flux is applied to the bottom surfaces and using a nanofluid diamond-water with 5% volume concentration of diamond nanoparticle as a coolant. The simulation has been carried out using the commercial software ANSYS-Fluent. Reynolds number (Re) has been taken between 200 and 400 with the corresponding inlet velocity from 1.53 m/s to 3.01 m/s, and the flow regime has been assumed to be stationary. The numerical results show that the parallelogram ribs position of the micro-channel in the second case gave an improvement in heat exchange, where the Nusselt number is higher than in the other cases, and showed a reduction in the temperature of the heated bottom wall compared to the other cases. Also, the micro-channel shape in the second case can be used to cool the electronic components. The results also showed that with increasing Reynolds number (Re), the friction factor of the micro-channel decreases in all cases. At the same time, we find the lowest value of the thermal resistance in the second case and the biggest value in the first case, base micro-channel without ribs.