Skip to content

Boron/nitrogen co-doped diamond electrode for highly efficient electrochemistry detection of aniline

MetadataDetails
Publication Date2021-01-02
JournalFunctional Diamond
AuthorsJiahan Li, Qiliang Wang, Yaofeng Liu, Zhigang Jiang, Junsong Liu
InstitutionsJilin University, Jilin Engineering Normal University
Citations14
AnalysisFull AI Review Included
  • A microwave plasma chemical vapor deposition (MPCVD) process produced conductive, polycrystalline boron/nitrogen co-doped diamond (BND) electrodes for trace aniline detection.
  • The BND electrode achieved a detection limit of 0.29 µmol L−1 and a linear detection range of 0.5-500 µmol L−1, outperforming conventional BDD and carbonaceous electrodes.
  • The improvement was attributed to synergistic boron and nitrogen doping, which increased electrochemical activity, reduced charge-transfer resistance, and increased the density of electrochemically accessible reaction sites.
  • The electrode consisted of a dense, predominantly (111)-oriented polycrystalline diamond film approximately 10 µm thick, deposited on a p-type silicon substrate measuring approximately 4.6 × 4.8 mm2.
  • Deposition was performed at approximately 850 °C, 7 kPa, and 8 h using CH4/H2/B/N2 flows of 2/200/2/2 sccm.
  • The electrode was evaluated in a three-electrode cell using 0.1 mol L−1 phosphate-buffered saline (PBS) at pH 2.0, a platinum-wire counter electrode, and a saturated calomel reference electrode.
  • The results support custom conductive diamond electrodes for electrochemical sensing, with BND suitable for applications requiring broad analyte concentration coverage and enhanced redox activity.
ParameterValueUnitContext
Target analyteAniline—Industrial and environmental contaminant
Electrode materialBoron/nitrogen co-doped polycrystalline diamond—MPCVD-deposited BND working electrode
Substratep-Type silicon—Deposition substrate
Substrate dimensions~4.6 × 4.8mm2Approximately 22.1 mm2 active substrate area
Deposition techniqueMicrowave plasma chemical vapor deposition—MPCVD growth process
Substrate temperature~850°CMonitored with an optical pyrometer
Total process pressure7kPaBND and BDD deposition condition
CH4 flow2sccmCarbon precursor
H2 flow200sccmCarrier and process gas
B-source flow2sccmBoron carried by hydrogen
N2 flow2sccmNitrogen co-doping source
Boron precursorB(OCH3)3—Trimethyl borate, liquid source at 25 °C
Boron-source temperature25°CLiquid-source operating condition
Deposition time8hFilm growth duration
BND film thickness~10µmCross-sectional SEM observation
BDD film thickness~9µmComparison material
BND grain size~1-2µmDense polycrystalline grains
Crystal orientationMainly (111)—XRD and Raman observations
Raman diamond peak1332cm−1Typical diamond zone-center phonon for BDD
BND non-diamond carbon band~1500cm−1Attributed mainly to grain-boundary carbon and C-N bonding
Raman excitation wavelength532nmRaman characterization
Electrochemical workstationCHI 760E—Three-electrode measurement system
Working electrodeConductive BND or BDD film—Tested as the analyte-sensing electrode
Counter electrodePlatinum wire—Auxiliary electrode
Reference electrodeSaturated calomel electrode—Potential reference
ElectrolytePBS—0.1 mol L−1 phosphate-buffered saline
Electrolyte pH2.0—Acidic measurement condition
Aniline standard range0.5-500µmol L−1Linear detection range reported for BND
Detection limit0.29µmol L−1Reported BND detection limit
BDD comparison detection limit1.0µmol L−1Previously reported BDD electrode
BDD comparison linear range1-140µmol L−1Previously reported BDD electrode
Measurement temperatureRoom temperature—Electrochemical characterization
  1. Prepare the growth substrates

    • Use p-type silicon substrates with an area of approximately 4.6 × 4.8 mm2.
    • Clean and load the substrates for MPCVD deposition.
  2. Set the deposition conditions

    • Maintain a substrate temperature of approximately 850 °C.
    • Use a total chamber pressure of 7 kPa.
    • Establish hydrogen as the carrier and process gas.
  3. Deposit the BND film

    • Introduce CH4, H2, boron source, and N2 at 2/200/2/2 sccm, respectively.
    • Use liquid B(OCH3)3 at 25 °C as the boron precursor.
    • Carry the boron source with hydrogen.
    • Deposit for 8 h to obtain a film approximately 10 µm thick.
  4. Prepare the BDD comparison electrode

    • Repeat the BND deposition process.
    • Omit N2 introduction while retaining the boron-doping conditions.
    • Obtain a BDD film approximately 9 µm thick.
  5. Characterize the films

    • Use SEM to examine morphology, grain structure, and cross-sectional thickness.
    • Use XRD to evaluate crystal orientation and phase quality.
    • Use Raman spectroscopy with 532 nm excitation to identify diamond and non-diamond carbon features.
    • Use XPS to evaluate surface bonding and boron/nitrogen chemical states.
  6. Prepare aniline standards

    • Dilute aniline in 0.1 mol L−1 PBS at pH 2.0.
    • Prepare standards spanning 0.5-500 µmol L−1.
  7. Perform electrochemical detection

    • Install the BND or BDD film as the working electrode.
    • Use a platinum-wire counter electrode and a saturated calomel reference electrode.
    • Measure the electrochemical response at room temperature using a CHI 760E workstation.
    • Compare BND and BDD responses to determine detection limit, linear range, stability, reproducibility, and usability.
  8. Interpret the doping mechanism

    • Correlate the improved BND performance with boron/nitrogen co-doping.
    • Assess changes in charge-transfer resistance, electrochemically accessible reaction-site density, electrochemical potential window, and surface redox activity.
Paper requirementRecommended 6CCVD materialRationale
Conductive diamond electrode for aniline oxidation and reductionConductive boron-doped polycrystalline diamond (PCD)Provides a conductive diamond matrix suitable for electrochemical sensing
Broad linear detection range and enhanced redox activityBoron/nitrogen co-doped PCD, customized for conductive electrochemical-grade performanceNitrogen incorporation can modify grain-boundary chemistry and electrochemical activity
Dense, predominantly (111)-oriented diamond grainsElectrochemical-grade PCD with controlled grain size and textureSupports reproducibility and stable electrode response
Film thickness near 10 µmCustom MPCVD PCD thickness from 0.1-500 µmEnables selection of a thin active layer or a mechanically robust free-standing electrode
Electrode substrate integrationPCD on silicon or custom substrateSupports experimental architectures similar to the reported silicon-supported device
Large-area or multi-electrode developmentPCD plates/wafers up to 125 mmEnables scale-up from laboratory coupons to engineered sensor formats
Higher-purity or single-crystal variantsSingle-crystal diamond (SCD)May be considered where surface uniformity and reduced grain-boundary contributions are prioritized
  • The reported electrode uses a small silicon-supported coupon, while 6CCVD can support custom PCD dimensions up to 125 mm.
  • 6CCVD can provide SCD and PCD across a broad thickness range:
    • SCD: 0.1-500 µm
    • PCD: 0.1-500 µm
    • Substrates: up to 10 mm
  • For a closely matched research configuration, 6CCVD can develop boron/nitrogen-doped PCD on silicon, with controlled film thickness, grain size, surface morphology, and electrical conductivity.
  • For practical sensor assemblies, 6CCVD can provide custom metallization using Au, Pt, Pd, Ti, W, and Cu.
  • Metallization can be engineered for:
    • Electrical contact formation
    • Low-resistance current collection
    • Platinum counter-electrode integration
    • Titanium or tungsten adhesion/intermediate layers
    • Gold or palladium contact pads
    • Copper interconnect integration
  • The electrode can also be adapted for a three-electrode cell through custom contact layouts, patterned active areas, and dimension-controlled working-electrode coupons.
  • 6CCVD offers polishing capabilities of:
    • Ra < 1 nm for SCD
    • Ra < 5 nm for inch-size PCD
  • Surface finishing can be selected to balance electrochemical response, contamination resistance, and device integration.
  • Laser cutting and custom shaping can be discussed for prototype sensor bodies, electrode coupons, and multi-electrode layouts, subject to material thickness and edge-quality requirements.
  • Global shipping is available, with DDU shipping as the default and DDP available on request.
  • 6CCVD’s in-house PhD team can assist with material selection for aniline electrochemical sensing, including:
    • Boron concentration and electrical conductivity
    • Nitrogen co-doping strategy
    • PCD grain morphology
    • Film thickness
    • Surface polishing and termination
    • Electrode geometry
    • Metallization stack selection
    • Silicon-supported versus free-standing architectures
  • For an application requiring the paper’s 0.29 µmol L−1 detection limit and 0.5-500 µmol L−1 linear range, 6CCVD can support a development program centered on conductive, electrochemically active PCD.
  • Nitrogen incorporation should be treated as a controlled process variable rather than a fixed composition. The concentration and bonding environment of nitrogen can affect grain-boundary sp2 carbon, charge-transfer behavior, and long-term electrode stability.
  • The optimal electrode architecture may differ between:
    • Research validation on silicon-supported films
    • Flow-through or batch electrochemical cells
    • Portable sensor cartridges
    • Industrial wastewater monitoring
    • High-throughput or multi-analyte platforms
Application requirement6CCVD solutionExpected development value
Trace aniline detectionConductive BDD or customized BND PCDDiamond provides low background current, chemical stability, and a wide electrochemical potential window
Wide analyte concentration rangeControlled conductivity and co-doped PCDSupports calibration across the reported 0.5-500 µmol L−1 range
Stable redox responseDense electrochemical-grade diamondReduces susceptibility to surface fouling from reaction products
Reproducible electrode responseControlled thickness, morphology, polishing, and geometrySupports device-to-device and batch-to-batch consistency
Electrical integrationAu, Pt, Pd, Ti, W, or Cu metallizationEnables custom contacts, pads, and cell interconnects
Scale-upPCD plates and wafers up to 125 mmSupports larger sensors, arrays, and production-oriented formats
High-surface-finish requirementsSCD Ra < 1 nm or PCD Ra < 5 nmEnables controlled surface preparation for sensitive electrochemical measurements

For custom specifications or material consultation, visit 6ccvd.com or contact our engineering team directly.

View Original Abstract

Aniline is a mutagenic and carcinogenic material for human health, and it is desirable to construct high-performance detecting system for the trace detection of aniline. In this work, the boron (B)/nitrogen (N)-doped diamond (BND) films prepared by chemical vapor deposition are proposed as electrochemical electrodes to detect aniline in a wide concentration scale. The BND electrodes have a high sensitivity (detect limitation of 0.29 μmol L−1) and a wide linear detection range (0.5 − 500 μmol L−1). Both the detection limitation and linear range are significantly improved with respect to that from traditional electrodes of boron-doped diamond and various carbonaceous materials, which can be attributed to the synergistic effect of increased electrochemistry reduction and density of reaction sites on the BND electrode surfaces. This work develops a kind of electrochemical electrodes of B/N-doped diamond films with high performances for quantitative detections of aniline in practical applications. Supplemental data for this article is available online at http://dx.doi.org/10.1080/26941112.2021.1939170