Repeatability of Small Field Output Factor Measurements with Various Detectors

MetadataDetails
Publication Date2021-01-01
JournalJournal of Medical Physics
AuthorsZakithi Lungile Mpumelelo Msimang, D. van der Merwe, Nkosingiphile Maphumulo
InstitutionsUniversity of the Witwatersrand
Citations2

There are well established dosimetry reference standards for broad beams; however, there are no reference standards that can be used for both broad and small fields. The variation of the equivalent square fields and field output factors in small static photon fields when using a synthetic diamond, an electron diode, and ionization chambers (pin point, semiflex, and liquid filled) was investigated over time. Data from this study were compared to the data from other hospitals in the country and standard data sets, i.e., the British Journal of Radiology Supplement No. 25 of 1996 (BJR25) and the Radiological Physics Centre (RPC) 2012 data. The results showed that reliance on one detector and one measurement session, could yield incorrect field output factors (FOFs) for small fields. At least one of the detectors should be a solid state type with published field output correction factors and at least three measurement sessions should be performed for each FOF data point. Comparing measured data with published datasets, like RPC, will assist in verifying data. BJR25 datasets should not be used for S clin ≤4 cm.

  1. 2008 - A new formalism for reference dosimetry of small and nonstandard fields [Crossref]
  2. 2008 - Small fields: Nonequilibrium radiation dosimetry [Crossref]
  3. 2008 - Lessons from recent accidents in radiation therapy in France [Crossref]
  4. 2006 - Analysis of photon beam data from multiple institutions: An argument for reference data [Crossref]
  5. 2019 - A novel method for the determination of field output factors and output correction factors for small static fields for six diodes and a microdiamond detector in megavoltage photon beams [Crossref]
  6. 2013 - A methodological approach to reporting corrected small field relative outputs [Crossref]
  7. 2012 - The Radiological Physics Center’s standard dataset for small field size output factors [Crossref]
  8. 2007 - Measurement of output factors for small photon beams [Crossref]
  9. 2009 - Task Group 142 report: Quality assurance of medical accelerators [Crossref]
  10. 2016 - Small field output factors: Comparison of measurements with various detectors and effects of detector orientation with primary jaw setting [Crossref]