  • Objective: Development of a high-speed machine-learning (ML) framework to rapidly predict optimal measurement parameters for Optically Detected Magnetic Resonance (ODMR) in nitrogen-vacancy (NV) centers hosted in fluorescent nanodiamonds.
  • Materials Studied: Fluorescent nanodiamonds (FNDs) containing NV centers, interrogated under varying laser and microwave (MW) power conditions.
  • Key Achievement: Demonstrated that linear regression, neural networks, and random forests can accurately predict ODMR contrast (up to ~14%) and signal-to-noise ratio (SNR up to ~50) using minimal experimental datasets.
  • Optimal Conditions Identified: Laser power ≈ 60-80 mW and MW power sweep centered around 0 dBm at ~2880 MHz yielded the highest contrast (R2 up to 0.92) and SNR performance.
  • Performance Benchmark: Neural networks achieved the best predictive accuracy (R2 = 0.92 for SNR; R2 = 0.90 for contrast), outperforming both linear regression and random forest models.
  • Impact: Reduces parameter-tuning overhead in quantum sensing protocols, enabling higher measurement throughput for temperature, magnetic field, pH, and electric-field biosensing applications.
  • Broader Applicability: The ML-driven optimization method is transferable to NMR, EPR, and fluorescence microscopy workflows.
ParameterValueUnitContext
Microwave (MW) Center Frequency~2880MHzNV center zero-field resonance (ZFS ≈ 2.87 GHz)
MW Power Sweep Range−10 to +10dBmTested for optimization of ODMR contrast
Optimal MW Power~0dBmMaximum contrast and SNR achieved
Laser Excitation Wavelength~532nmStandard green laser excitation for NV centers
Laser Power Range0-100mWSwept during optimization
Optimal Laser Power~60-80mWHighest ODMR contrast region
ODMR Contrast Range0-14%Observed across experimental conditions
Peak ODMR Contrast~14%Maximum reported during sweep
SNR Range0-50a.u.Observed across experimental conditions
Peak SNR~50a.u.Maximum reported during sweep
EM Gain Range0-10a.u.Detector gain parameter swept
Exposure Time Range0-0.08sIntegration time per acquisition
Prediction Accuracy - Contrast (Neural Network)R2 = 0.90—Best ML model for contrast prediction
Prediction Accuracy - SNR (Neural Network)R2 = 0.92—Best ML model for SNR prediction
Prediction Accuracy - Contrast (Linear Regression)R2 = 0.88—Baseline ML model
Prediction Accuracy - SNR (Linear Regression)R2 = 0.80—Baseline ML model
Prediction Accuracy - Contrast (Random Forest)R2 = 0.86—Ensemble ML model
Prediction Accuracy - SNR (Random Forest)R2 = 0.77—Ensemble ML model
Sample TypeFluorescent Nanodiamonds (FNDs)—NV-containing diamond nanoparticles
Sample GeometryParticle suspension (spin-coated on slide glass)—Wide-field ODMR configuration
Objective Lens Magnification0.95NAHigh-NA confocal/wide-field collection
  • Sample Preparation: Fluorescent nanodiamonds synthesized via one-pot dispersion method, deposited on slide glass for wide-field ODMR interrogation.
  • Optical Setup: Green laser excitation routed through objective (NA = 0.95); fluorescence collected via CMOS or photodetector after appropriate dichroic filtering.
  • Microwave Delivery: Strip-line or coil resonator coupled to MW generator tuned to ~2880 MHz for NV ground-state electron spin resonance.
  • Parameter Sweeping: Laser power (0-100 mW), MW power (−10 to +10 dBm), EM gain (0-10 a.u.), and exposure time (0-0.08 s) varied systematically.
  • Data Acquisition: ODMR spectra recorded as fluorescence intensity vs. MW frequency across 2860-2900 MHz range.
  • Feature Extraction: Extracted ODMR contrast (%) and SNR (a.u.) from each spectrum as target variables.
  • Machine Learning Pipeline:
    • Dataset partitioning into training (80%) and test (20%) subsets.
    • Three ML models trained: Linear Regression, Neural Network (multi-layer), Random Forest.
    • Input features: Laser power, MW power, EM gain, exposure time, and magnetic/optical parameters.
    • 10-fold cross-validation applied to assess generalization.
  • Validation: Predicted optimal laser/MW powers cross-checked against experimentally measured ODMR spectra; close agreement confirmed model fidelity.
  • Applicable Materials:

    • Optical-Grade Single Crystal Diamond (SCD): Ideal for bulk NV ensemble sensing where high coherence and controlled defect density are required. 6CCVD supplies SCD wafers with tailored NV concentrations for quantum sensing R&D.
    • Polycrystalline Diamond (PCD) with NV Centers: Suitable for ensemble ODMR and wide-field magnetometry applications requiring larger active areas or flexible form factors.
    • Boron-Doped Diamond (BDD): Available for combined electronic-spin and electrochemical sensing modalities (e.g., pH, redox sensing in biological environments).
    • Fluorescent Nanodiamond Feedstock: For researchers scaling up FND-based biosensing, 6CCVD can provide high-purity detonation or HPHT nanodiamond precursors with custom surface functionalization consultation.
  • Customization Potential:

    • Dimensions: 6CCVD delivers custom wafer dimensions up to 125 mm diameter (PCD) and tailored thicknesses from 0.1 µm to 500 µm (SCD/PCD) — well-suited for both bulk NV ensemble devices and thin-film integration.
    • Metalization: The paper’s resonator/coil structures benefit from robust MW delivery electrodes. 6CCVD offers in-house metalization (Au, Pt, Pd, Ti, W, Cu) with custom patterning to fabricate strip-line resonators, microwave waveguides, and microcoils directly on diamond substrates.
    • Laser Cutting & Dicing: Custom shaping of diamond chips for slide-mounted or microfluidic ODMR chambers is available via 6CCVD’s precision laser processing.
    • Surface Polishing: For experiments demanding ultra-low optical scattering, 6CCVD provides Ra < 1 nm (SCD) and Ra < 5 nm (inch-size PCD) surface finishes — critical for maximizing fluorescence collection efficiency in ODMR setups.
  • Engineering Support:

    • 6CCVD’s in-house PhD engineering team can assist with material selection for NV-center quantum sensing projects, including guidance on optimal NV density, defect engineering, and diamond-substrate integration with MW resonator architectures.
    • Consultation available for pairing diamond material properties (e.g., coherence time, spin-lattice relaxation) with experimental parameters like the ~2880 MHz resonance frequency used in this study.
    • Support for scaling laboratory ODMR protocols toward device-ready sensor modules.
  • Call to Action:

    • For custom specifications, metalized resonator substrates, or material consultation tailored to your quantum sensing or ODMR research, visit 6ccvd.com or contact our engineering team directly.
View Original Abstract

Determination of optimal measurement parameters is essential for measurement experiments. They can be manually optimized if the linear correlation between them and the corresponding signal quality is known or easily determinable. However, in practice, this correlation is often nonlinear and not known a priori; hence, complicated trial and error procedures are employed for finding optimal parameters while avoiding local optima. In this work, we propose a novel approach based on machine learning for optimizing multiple measurement parameters, which nonlinearly influence the signal quality. Optically detected magnetic resonance measurements of nitrogen-vacancy centers in fluorescent nanodiamonds were used as a proof-of-concept system. We constructed a suitable dataset of optically detected magnetic resonance spectra for predicting the optimal laser and microwave powers that deliver the highest contrast and signal-to-noise ratio values by means of linear regression, neural networks, and random forests. The model developed by the considered neural network turned out to have a coefficient of determination significantly higher than that of the other methods. The proposed method thus provided a novel approach for the rapid setting of measurement parameters that influence the signal quality in a nonlinear way, opening a gate for fields like nuclear magnetic resonance, electron paramagnetic resonance, and fluorescence microscopy to benefit from it.