Charge transport in single crystal CVD diamond studied at high temperatures
At a Glance
Section titled “At a Glance”| Metadata | Details |
|---|---|
| Publication Date | 2021-08-17 |
| Journal | Journal of Physics D Applied Physics |
| Authors | Andreo Crnjac, M. Rodríguez-Ramos, N. Skukan, M. Pomorski, M. Jakšić |
| Institutions | CEA LIST, International Atomic Energy Agency |
| Citations | 8 |
| Analysis | Full AI Review Included |
Executive Summary
Section titled “Executive Summary”- Objective: Investigates charge transport in high-purity single crystal CVD (sc-CVD) diamond radiation detectors operating at extreme temperatures (up to 450°C) under MeV ion exposure.
- Material Baseline: Uses high-purity sc-CVD diamond with [N] < 5 ppb, [B] < 1 ppb, <100> orientation, and 65 µm thickness, featuring tungsten planar electrodes.
- Radiation Damage Source: 5 MeV protons used to induce controlled lattice defects; ionization probing conducted with 3 MeV He⁺ ions (Ion Beam Induced Charge - IBIC technique).
- Key Discovery - Hole Trap Activation: Identified a radiation-induced deep hole trap with activation energy Ea = 0.53 ± 0.01 eV and capture cross-section σ ≈ 2.42 × 10⁻¹⁷ cm², observed only in proton-damaged regions.
- Thermal Detrapping Threshold: Charge release from the deep trap becomes significant above 200°C, with complete signal saturation/recovery observed near 380°C-450°C.
- Charge Carrier Behavior: Hole mobility-lifetime (µτ) product degrades roughly one order of magnitude from RT to 450°C; electron µτ is more stable and exhibits unexpected recovery above 250°C.
- Defect Hypothesis: Vacancies (V) remain immobile below 600°C, suggesting the observed trap is an interstitial (I)-related center introduced during MeV proton irradiation.
Technical Specifications
Section titled “Technical Specifications”| Parameter | Value | Unit | Context |
|---|---|---|---|
| Diamond Type | sc-CVD (Single Crystal) | — | High-purity detector grade |
| Crystal Orientation | <100> | — | Standard epitaxial plane |
| Thickness | 65 | µm | Active detector volume |
| Nitrogen Concentration | < 5 | ppb | Ultra-low for minimal compensation |
| Boron Concentration | < 1 | ppb | Intrinsic-grade purity |
| Electrode Material | Tungsten (W) | — | High-temperature metallization |
| Operating Temperature Range | 23 - 450 | °C | Full characterization span |
| Applied Electric Field Range | -0.8 to +1.2 | V/µm | Bipolar drift measurement |
| Damaging Ion Beam | 5 MeV H⁺ (protons) | — | Defect induction |
| Probing Ion Beam (PIB) | 3 MeV He⁺ | — | Charge signal generation (IBIC) |
| Probing Ion Beam (DIB) | 5 MeV H⁺ | — | Additional IBIC characterization |
| Trap Activation Energy (Ea) | 0.53 ± 0.01 | eV | Hole-only deep trap |
| Capture Cross-Section (σ) | 2.42 × 10⁻¹⁷ | cm² | Order-of-magnitude estimate |
| Hole Effective Mass (m*h) | 0.46 m₀ | — | Used for emission rate calculation |
| µτ Degradation (Holes) | ~1 order of magnitude | — | From RT to 450°C |
| Signal Recovery Onset | ~380 | °C | CCE saturation point |
| Free Carrier Density (RT) | ~10⁻²⁷ | cm⁻³ | Negligible intrinsic |
| Free Carrier Density (500°C) | ~10 | cm⁻³ | Still negligible |
Key Methodologies
Section titled “Key Methodologies”- Detector Fabrication: Mounted 65 µm thick sc-CVD diamond with W planar electrodes onto a specialized high-temperature housing; one side kept open for ion beam access.
- Ion Microbeam Induced Charge (IBIC) Mapping: Used focused MeV ion beams at the Ruđer Bošković Institute microprobe facility for spatially resolved charge collection efficiency (CCE) imaging.
- Radiation Damage Protocol: Pre-irradiated specific detector regions with 5 MeV protons to create well-defined damaged vs. pristine zones for comparative analysis.
- Charge Transient Spectroscopy (CTS): Recorded time-resolved charge pulses using a fast digital oscilloscope (LeCroy WaveMaster 8500A, 20 GS/s) coupled to an Ortec 142A charge-sensitive preamplifier.
- Hecht Equation Fitting: Extracted mobility-lifetime (µτ) products by fitting CCE vs. applied electric field curves across the full temperature range for both polarities.
- Arrhenius Analysis: Plotted inverse detrapping times vs. reciprocal temperature to determine activation energy (Ea) and capture cross-section (σ) of the radiation-induced trap.
- Thermal Cycling: Performed measurements at discrete setpoints (RT, 176°C, 250°C, 275°C, 300°C, 325°C, 350°C, 378°C, 395°C, 450°C) under controlled resistive heater + thermocouple feedback.
6CCVD Solutions & Capabilities
Section titled “6CCVD Solutions & Capabilities”-
Applicable Materials:
- Optical/Electronic Grade SCD with [N] < 5 ppb and [B] < 1 ppb specifications is required to replicate these findings. 6CCVD supplies ultra-high-purity Single Crystal Diamond (SCD) with comparable purity grades and provides thicknesses from 0.1 µm to 500 µm, enabling full replication of the 65 µm detector geometry or exploration of thinner geometries for faster signal response.
- For applications requiring larger active areas or alternative geometries, 6CCVD’s Polycrystalline Diamond (PCD) wafers up to 125 mm diameter are available, with thicknesses up to 10 mm for substrate-level work.
-
Customization Potential:
- This paper relies on tungsten (W) planar electrodes for high-temperature resilience. 6CCVD offers in-house tungsten (W), titanium (Ti), platinum (Pt), palladium (Pd), gold (Au), and copper (Cu) metallization via sputtering/evaporation, allowing rapid prototyping of similar electrode stacks.
- Custom lateral dimensions and laser-cutting services are available to match the open-geometry detector architecture described, including thin membranes for transmission-mode ion beam experiments.
-
Engineering Support:
- 6CCVD’s in-house PhD engineering team can assist with material selection for high-temperature radiation detector projects, including guidance on purity optimization (N/B specification), crystal orientation choices, and electrode-metal stack engineering for operation in the 200°C-450°C regime.
- For experiments targeting trap spectroscopy or detrapping kinetics, 6CCVD can supply matched reference samples (pristine vs. custom-doped variants) to support controlled comparative studies.
-
Call to Action: For custom specifications, metallization stacks, or material consultation on high-temperature semiconductor device development, visit 6ccvd.com or contact our engineering team directly.
View Original Abstract
Abstract The capability of single crystal diamonds to maintain their unique electronic properties even at high temperatures is, in particular, relevant for its applications as a radiation detector. In order to explore characteristics of charge transport at high temperatures (up to 450 ∘ C), diamond was exposed to MeV energy ions, both, to induce radiation damage and to probe subsequent influence on detector’s properties. Dependence of mobility-lifetime product with temperature has been obtained for electrons and holes. For holes, mu-tau displays a linear degradation with rising temperature, while for electrons, change with temperature is less evident. Furthermore, deep trapping levels induced in the material by radiation damage, were studied through time-resolved charge signals. Detrapping time was extracted from this data. Hole trap level, with the activation energy of 0.53 ± 0.01 eV has been detected in the regions of the diamond detector previously irradiated by 5 MeV damaging proton beam, but not in the pristine regions. This indicates that the trap was formed due to defect induction during radiation damage exposure. Activation of this deep level is important for charge transport performance in diamond detectors operating at high temperatures and high radiation conditions.
Tech Support
Section titled “Tech Support”Original Source
Section titled “Original Source”References
Section titled “References”- 2013 - Growth of large size diamond single crystals by plasma assisted chemical vapour deposition: recent achievements and remaining challenges [Crossref]
- 2014 - Large-area high-quality single crystal diamond [Crossref]
- 2008 - Diamond as an electronic material [Crossref]
- 2016 - Development and high temperature testing by 14 MeV neutron irradiation of single crystal diamond detectors [Crossref]
- 2017 - Diamond based detectors for high temperature, high radiation environments [Crossref]
- 2020 - Systematic study of the response of single crystal diamond neutron detectors at high temperature [Crossref]
- 2013 - High-temperature operation of diamond junction field-effect transistors with lateral p-n junctions [Crossref]
- 2021 - Charge carrier properties of single-crystal CVD diamond up to 473 K [Crossref]
- 2017 - Diamond detectors for high-temperature transactinide chemistry experiments [Crossref]