LGAD technology for heavy ion detection and radiation damage diagnostics in diamond
At a Glance
Section titled “At a Glance”| Metadata | Details |
|---|---|
| Publication Date | 2025-08-01 |
| Journal | Journal of Instrumentation |
| Authors | Jerzy Pietraszko, Ashish Bisht, T. Bergauer, Henrik Floersheimer, J. Frühauf |
| Institutions | Technical University of Darmstadt, Goethe University Frankfurt |
| Analysis | Full AI Review Included |
LGAD Technology for Heavy Ion Detection and Radiation Damage Diagnostics in Polycrystalline CVD Diamond
Section titled “LGAD Technology for Heavy Ion Detection and Radiation Damage Diagnostics in Polycrystalline CVD Diamond”Executive Summary
Section titled “Executive Summary”- Application Focus: The paper demonstrates the integration of Low Gain Avalanche Detector (LGAD) amplifier technology with polycrystalline CVD (pcCVD) diamond sensors to compensate for heavy-ion-induced radiation damage, targeting high-precision Time-of-Flight (ToF) measurements in high-energy physics experiments (e.g., FAIR/CBM).
- Material Validation: Confirms pcCVD diamond as a robust, radiation-hard sensor material capable of in-vacuum operation without active cooling, leveraging fast drift velocities of both electrons and holes.
- Amplification Innovation: A dedicated multi-stage analog amplifier system (built around the BFR840L SiGe RF transistor with AC coupling) compensates for signal degradation by a factor of ~173 (Au vs. C ions), significantly extending detector operational lifetime.
- Timing Performance: Achieved sub-40 ps timing resolution using LGAD strip sensors for heavy ion detection, with a single LGAD sensor precision of 28.9 ps for 402 MeV/u carbon ions.
- Radiation Damage Quantification: Demonstrated localized efficiency maps of radiation-damaged diamond sensors, providing precise diagnostics of degradation across the 1 cm × 1 cm active area.
- Beam Telescope Methodology: Validated a beam telescope setup combining irradiated pcCVD diamond with LGAD reference detectors at the MedAustron facility using He (205.2 MeV/u) and C (402 MeV/u) ion beams.
- Key Achievement: Despite radiation damage, the amplifier-compensated pcCVD diamond maintained full detection efficiency for carbon ions while enabling precise position-correlated timing analysis.
Technical Specifications
Section titled “Technical Specifications”| Parameter | Value | Unit | Context |
|---|---|---|---|
| Diamond Sensor Active Area | 1 × 1 | cm | pcCVD diamond sensor (e6.com manufactured) |
| Diamond Sensor Thickness | 70 | µm | Optimized for heavy ion detection |
| Metallization Composition | Cr/Au | — | 16 readout strips per side |
| Strip Count (per side) | 16 | strips | Wire-bonded to amplifier PCB |
| Bond Wire Diameter | 20 | µm | Al/Au wire bonds to amplifier system |
| He Ion Beam Energy | 205.2 | MeV/u | MedAustron facility |
| C Ion Beam Energy | 402 | MeV/u | MedAustron facility |
| Beam Intensity | 106 | ions/s | Helium beam test |
| Time Coincidence Window | ±30 | ns | Applied between all three sensors |
| LGAD Timing Precision (single sensor) | 28.9 | ps | For 402 MeV/u C ions |
| LGAD ToF Resolution | < 30 | ps | System-level time-of-flight |
| Diamond Timing Precision (low damage) | 47.9 | ps | Channel 4, sigma = 56.0 ps |
| Diamond Timing Precision (high damage) | 139.0 | ps | Channel 7, sigma = 142.0 ps |
| Signal Amplitude Ratio (He:C:Au) | 4:36:6241 | — | Proportional to Z2 |
| Amplification Compensation Factor | ~173 | — | Au-to-C signal amplitude ratio |
| LGAD Readout Channels | 32 | channels | Per DiRich5s board (FPGA-based) |
| Transistor Type | BFR840L | — | Low-noise SiGe bipolar RF transistor |
| Operating Temperature | Room Temp | °C | No active cooling required |
Key Methodologies
Section titled “Key Methodologies”- Diamond Sensor Selection: Selected a previously irradiated pcCVD diamond sensor (1 cm × 1 cm, 70 µm thickness, Cr/Au metallization) from the mCBM experiment at GSI, which had been exposed to intense Au and Ag heavy-ion beams.
- Amplifier System Design: Constructed a multi-stage analog amplification chain comprising AC coupling, a first-stage preamplifier (BFR840L), and a second-stage amplifier with signal shaping to detect small signals from radiation-damaged diamond regions.
- Readout Integration: Connected 16 strips on one side of the diamond sensor to the amplifier PCB via 20 µm wire bonds; implemented the full readout chain using DiRich5s FPGA-based boards (32 channels per board).
- Beam Telescope Assembly: Integrated the diamond sensor with two reference LGAD strip sensors (X and Y planes) to form a coincidence-based beam telescope for heavy ion detection.
- Time Calibration Procedure: Applied offset and time-walk corrections to all channels via leading-edge discrimination; used cluster finder algorithms to reject noise.
- He Beam Characterization (205.2 MeV/u): Tested detection efficiency and timing performance; mapped efficiency drop in the central region corresponding to localized radiation damage.
- C Beam Characterization (402 MeV/u): Re-tested with carbon ions; achieved full detection efficiency across the sensor area, validating amplification compensation.
- Timing Precision Analysis: Compared ToA differences between LGAD reference (channel 22) and pcCVD diamond channels to quantify radiation-induced timing degradation.
- Efficiency Mapping: Computed 2D efficiency maps by taking the ratio of coincident LGAD-LGAD hits to LGAD-LGAD-Diamond triple coincidences.
- LGAD Validation: Independently validated LGAD strip sensor performance for heavy ion detection using the C beam, achieving 28.9 ps single-sensor timing precision.
6CCVD Solutions & Capabilities
Section titled “6CCVD Solutions & Capabilities”Applicable Materials
Section titled “Applicable Materials”For replicating or extending this radiation-hard heavy-ion detection research, 6CCVD recommends:
| 6CCVD Product Grade | Recommended Application | Key Advantage |
|---|---|---|
| Polycrystalline CVD Diamond (PCD) | Direct replication of the pcCVD sensor used (e6.com-equivalent) | Thickness range 0.1 µm - 500 µm; inch-size polishing capability (Ra < 5 nm) |
| Optical Grade SCD | Higher timing precision experiments requiring single-crystal uniformity | Superior charge collection, Ra < 1 nm polish available |
| Heavy Boron-Doped PCD (BDD) | Radiation-hard detector electrodes requiring conductive diamond | Enables all-carbon detector architectures with simplified metallization |
| Custom-Thickness PCD (70 µm spec) | Exact replication of the 70 µm sensor thickness used in this work | Precision thickness control down to ±2 µm |
Customization Potential
Section titled “Customization Potential”- Custom Metalization: 6CCVD provides in-house Cr/Au, Ti/Au, Ti/Pt/Au, and other metallization stacks tailored for strip, pad, or pixel electrode patterning. The 16-strip Cr/Au metallization used in this paper can be replicated or scaled to higher strip densities (e.g., 32, 64 strips).
- Laser Cutting Services: 6CCVD offers precision laser dicing and cutting for custom sensor geometries, including the 1 cm × 1 cm active area and larger formats up to 125 mm diameter for PCD wafers.
- Thickness Optimization: Custom PCD thicknesses from 0.1 µm to 500 µm enable tuning of the active detector volume for specific ion species and energy ranges (He, C, Au beams).
- Large-Area Scaling: For next-generation FAIR/CBM experiments requiring larger active areas, 6CCVD’s 125 mm PCD wafer capability provides a clear scaling path beyond the 1 cm × 1 cm sensors tested here.
Engineering Support
Section titled “Engineering Support”The integration of amplification electronics with diamond sensors requires careful matching of sensor capacitance, leakage current, and signal characteristics. 6CCVD’s in-house PhD engineering team can assist with:
- Material Selection: Guidance on choosing PCD vs. SCD vs. BDD for specific heavy-ion detection scenarios and radiation hardness targets.
- Electrode Design: Consultation on strip/pixel patterning, metallization stack selection, and edge termination for high-voltage operation.
- Sensor Characterization: Recommendations on pre-irradiation QA testing protocols, including charge collection distance (CCD) measurements and timing characterization.
- Amplifier Integration: Advice on matching sensor output impedance to low-noise front-end electronics such as the BFR840L-based amplifiers demonstrated in this work.
- Application-Specific Consultation: Dedicated support for nuclear physics, medical dosimetry, synchrotron beam monitoring, and space radiation detection projects.
Call to Action
Section titled “Call to Action”For custom specifications, material consultation, or metallization design assistance for your heavy-ion detection or radiation-hard sensor development project, visit 6ccvd.com or contact our engineering team directly. Global shipping is available (DDU default, DDP available upon request) to support research facilities worldwide.
View Original Abstract
Abstract We present the application of LGAD technology for time-of-flight measurements of heavy ions and for precise diagnostics of radiation damage in diamond sensors. The polycrystalline CVD (pcCVD) diamond sensor used in this work was irradiated with heavy ion beams at GSI, Darmstadt, Germany during several experimental campaigns and subsequently investigated at MedAustron, Wiener Neustadt, Austria. To mitigate radiation-induced performance degradation, we propose a dedicated amplification system originally developed for LGAD sensors, which significantly extends the operational lifetime of diamond detectors. For precise sensor diagnostics, we employed strip LGAD sensors — commonly used for minimum ionizing particle (MIP) detection — and demonstrated their excellent performance for heavy ion (He/C) detection, achieving timing resolutions below 40 ps.
Tech Support
Section titled “Tech Support”Original Source
Section titled “Original Source”References
Section titled “References”- 2009 - The High-Acceptance Dielectron Spectrometer HADES [Crossref]
- 2010 - Diamonds as timing detectors for MIP: The HADES proton-beam monitor and start detectors [Crossref]
- 2014 - Radiation damage in single crystal CVD diamond material investigated with a high current relativistic ^197Au beam [Crossref]
- 2020 - Low Gain Avalanche Detectors for the HADES reaction time (T_0) detector upgrade [Crossref]
- 2023 - Novel ion imaging concept based on time-of-flight measurements with low gain avalanche detectors [Crossref]
- 2024 - First experimental time-of-flight-based proton radiography using low gain avalanche diodes [Crossref]
- 2022 - Low Gain Avalanche Detector Application for Beam Monitoring [Crossref]
- 2022 - LGAD technology for HADES, accelerator and medical applications [Crossref]
- 2022 - Status of Diamond and LGAD Based Beam-Detectors for the mCBM and CBM Experiments at GSI and FAIR [Crossref]