Skip to content

Urea-to-AmmoniaConversion at Proteus mirabilis Modified Pt–Ni/BDD Electrodes

FieldValue
JournalACS Omega
Published2026-07-20
AuthorsAbayomi Omoogun, Galilea De La O, Suzatra Chatterjee, Leslie Janet Prieto Gómez, Nicole I. Jones
DOI10.1021/acsomega.5c12415

The Pt-Ni/BDD bioelectrode produced a maximum current density of 0.0055 mA cm⁻² during urea processing in synthetic urine. The best reported condition used Proteus mirabilis immobilized at -0.3 V vs Ag/AgCl, saturated KCl, for 9 h. The authors attributed the main response to sequential bacterial ureolysis and electrochemical ammonia oxidation, not direct urea oxidation at the electrode.

The bioelectrochemical reaction had two stages. P. mirabilis produced urease, which hydrolyzed urea into ammonia and carbon dioxide. The Pt-Ni layer then oxidized the generated ammonia at the working electrode.

Measurements used 20 mL of synthetic urine containing 0.1 M urea. After 15 min of enzymatic hydrolysis, cyclic voltammetry ran from 0.2 to 0.8 V at 1 mV s⁻¹ under argon. The bioelectrode showed a broad anodic oxidation peak at approximately 0.55 to 0.75 V vs Ag/AgCl, saturated KCl.

Without bacteria, bare BDDE in synthetic urine and Pt-Ni/BDDE in urea-depleted synthetic urine showed no detectable oxidation peak. The authors therefore assigned the main response to ammonia generated at the bacterial electrode interface.

Electrode preparation and surface characterization

Section titled “Electrode preparation and surface characterization”

The starting BDDE was a 0.6 mm polycrystalline CVD diamond film with a 0.18 cm² active geometric area. Its resistivity was 0.02 to 0.18 Ω cm, and its boron concentration exceeded 10²⁰ atoms cm⁻³.

Preparation stepSolution or treatmentPotential vs Ag/AgCl, saturated KClTime or scan rate
Chemical activationAqua regiaNot appliedNot stated
Electrochemical cleaning0.5 M H₂SO₄-0.5 to 0.5 V100 mV s⁻¹
Cathodic polarization0.5 M H₂SO₄-3 V5 min
Ni electrodeposition5 mL of 5 mM NiCl₂ plus 5 mL of 0.1 M KClO₄-0.9 V20 s
Pt electrodeposition5 mL of 1 mM K₂PtCl₄ plus 5 mL of 0.1 M KClO₄-0.25 V120 s

The sequential deposition produced 4.16 × 10⁻⁴ mg Ni and 1.95 × 10⁻³ mg Pt on the diamond. SEM showed dense, granular coverage with nanoscale clusters, and EDS confirmed Pt and Ni on the carbon support.

Raman spectroscopy retained the diamond lattice peak near 1329 cm⁻¹ after modification. The modified sample also showed bands near 1230 and 1553 cm⁻¹. The authors assigned the 1553 cm⁻¹ G band to minor graphitic or amorphous carbon.

Bacterial immobilization produced a dense biofilm

Section titled “Bacterial immobilization produced a dense biofilm”

The authors grew P. mirabilis ATCC 7002 in low-salt LB broth at 37 °C for 24 h with shaking at 200 rpm. After 6 h in Christensen’s urea agar, P. mirabilis showed greater urease activity than P. vulgaris, a mixed culture, and E. coli.

Initial immobilization on bare BDDE used -0.5 V for 4 h at room temperature. The reported pH was 5.04, and SEM showed dense, intact rod-shaped cells. The authors related stronger adhesion at negative potentials to electrostatic attraction between bacterial cells and the polarized diamond surface.

On Pt-Ni/BDD, the potential screen compared open circuit with -0.1, -0.2, and -0.3 V at 1, 3, 5, and 7 h. A separate time study used -0.3 V with 1, 3, 5, 9, and 12 h. SEM showed progressively denser coverage across the potential and time series, except for aggregation after 12 h.

Potential and time controlled the current response

Section titled “Potential and time controlled the current response”

The ammonia oxidation response ranked -0.3 V above -0.2 V, -0.1 V, and open circuit. Open-circuit immobilization began at 0.11 V and settled near -0.05 V after 1 h. More negative potentials gave stronger current stabilization during biofilm formation.

At -0.3 V, the peak current increased with immobilization time through 9 h. The main text reports 0.005 mA cm⁻² at 9 h, while the abstract reports 0.0055 mA cm⁻². The solution pH rose from 8.60 after 1 h to 8.88 after 12 h. At 12 h, SEM showed bacterial overaccumulation and aggregation, and the catalytic current declined. The authors linked this decline to pH-induced stress on P. mirabilis.

Controls tested catalyst and biofilm effects

Section titled “Controls tested catalyst and biofilm effects”

Bacteria immobilized on bare BDDE at -0.3 V for 5 h produced no distinct ammonia oxidation peak. The current instead rose gradually from about 0.0002 mA cm⁻² at 0.2 V to about 0.0010 mA cm⁻² at 0.9 V. The authors treated this as background oxidation because the bare surface lacked the Pt-Ni catalyst.

In a later comparison in synthetic urine with 0.1 M urea, P. mirabilis/Pt-Ni/BDD began oxidation near 0.45 V vs Ag/AgCl, saturated KCl. Sterile Pt-Ni/BDD showed a delayed peak of about 0.012 mA cm⁻² near 0.8 V. The comparison used pH 8.85 for the bioelectrode and pH 9.09 for the sterile electrode. The authors assigned the higher-potential peak to direct oxidation of ammonia or urea in the bulk solution.

The earlier Pt-Ni/BDDE control in urea-depleted synthetic urine showed no detectable peak. These control descriptions leave the catalyst-only contribution dependent on electrolyte history and potential window. The paper assigns the main response in the biofilm experiments to the biofilm-mediated ammonia pathway.

Chronoamperometry at 0.55 V ran for 24 h in synthetic urine containing 0.1 M urea. The bioelectrode maintained a higher and more stable current than sterile Pt-Ni/BDD. The comparison used pH 9.43 for the bioelectrode and pH 8.91 for the sterile electrode. The authors attributed the stable response to in situ ammonia production and resistance to passivation.

The text reports no numerical current decay rate, Faradaic efficiency, urea conversion, ammonia removal, or product yield. The ammonia oxidation reaction is described as a three-electron process that produces nitrogen and hydrogen, but the study did not quantify those products. The reported current was therefore an electrochemical activity measure, not a demonstrated water treatment efficiency.

The authors identify real urine matrices, alternative microbial strains, and quantitative product analysis as unresolved work. They also used synthetic urine rather than a full wastewater matrix. The motivation came from International Space Station water recovery, which can recycle approximately 90% of total wastewater and 74% to 85% of human urine. The paper did not measure water recovery, so it cannot be compared directly with those water recovery percentages.

Implications for material and device selection

Section titled “Implications for material and device selection”

The measured response separates the two material functions. Boron-doped diamond provided the adherent, low-background support, while Pt-Ni supplied the catalytic sites needed for the reported ammonia oxidation signal. Bare diamond with bacteria did not yield a distinct oxidation peak.

Process development should treat biofilm loading at -0.3 V for 9 h as a separate step from oxidation near 0.55 V. pH control also matters because ammonia production raised pH, and the 12 h biofilm showed aggregation with lower current. The 0.0055 mA cm⁻² value reports laboratory activity, not a conversion rate or energy balance. Real urine tests and quantitative nitrogen product analysis remain necessary before scale-up.

The paper’s electrode uses a boron-doped diamond substrate with a Pt-Ni catalytic layer for ammonia oxidation during synthetic urine treatment. 6CCVD offers boron-doped diamond and Pt metallization through its diamond materials catalog, which matches the substrate and Pt portion of the design. The 0.6 mm film geometry and Ni incorporation would need a separate specification review through engineering support.

View Original Abstract

Abstract Efficient wastewater recycling technologies are essential for long-duration space missions and sustainable water management on Earth. Here, a bioelectrochemical system integrating Proteus mirabilis with a platinum-nickel-modified boron-doped diamond electrode (Pt-Ni/BDDE) for urea-to-ammonia conversion in synthetic urine is presented. Immobilized P. mirabilis catalyzes enzymatic ureolysis, converting urea into ammonia, which is subsequently oxidized electrochemically, and no direct electrochemical urea oxidation is observed. Cyclic voltammetry (CV) of P. mirabilis on Pt-Ni/BDDE in 0.1 M urea and synthetic urine revealed a broad anodic oxidation peak at approximately 0.55-0.75 V vs Ag/AgCl (sat. KCl), corresponding to ammonia oxidation. Control experiments using bare BDDE and Pt-Ni/BDDE in synthetic urine showed no oxidation peak, establishing that the bioelectrocatalytic response originates exclusively from the bioelectrode interface. Chronoamperometry studies revealed that immobilization potential and time critically influenced bacterial adhesion and electrochemical response, with optimal conditions yielding a maximum current density of 0.0055 mA·cm-2. These quantitative results establish that microbial ureolysis can be efficiently coupled with advanced electrode materials for urea-to-ammonia conversion, offering a promising self-sustaining strategy for urine processing and water recovery in closed-loop life support systems.

  1. 2004 - Effect of pretreatment on the fouling of membranes: application in biologically treated sewage effluent [Crossref]
  2. 2013 - Design, Construction, and Testing of the Forward Osmosis Secondary Treatment System to Treat Bioreactor Effluent [Crossref]
  3. 2016 - Enhancing wastewater reuse by forward osmosis with self-diluted commercial fertilizers as draw solutes [Crossref]
  4. **** - ISS ECLSS Technology Evolution for Exploration. 43rd AIAA Aerospace Sciences Meeting and Exhibit
  5. 1996 - Separate management of anthropogenic nutrient solutions (human urine) [Crossref]
  6. 2003 - Nutrients in urine: energetic aspects of removal and recovery [Crossref]
  7. 2021 - Next Generation Water Recovery for a Sustainable Closed Loop Living
  8. 2014 - Evaluation of a Urea Bioelectrochemical System for Wastewater Treatment Processes [Crossref]
  9. 2020 - A five-stage treatment train for water recovery from urine and shower water for long-term human Space missions [Crossref]