Skip to content

A High Dynamic Range Diamond Detector Readout System for the CERN Beam Wire Scanners Program

MetadataDetails
Publication Date2016-01-01
JournalCERN Document Server (European Organization for Nuclear Research)
AuthorsJose Sirvent Blasco, Bernd Dehning, Á. Diéguez, Jonathan Emery
InstitutionsEuropean Organization for Nuclear Research
AnalysisFull AI Review Included
  • Core Application: Development and evaluation of a polycrystalline CVD (pCVD) diamond detector for high-energy particle beam monitoring in accelerator physics environments.
  • Detection Mechanism: Utilizes a high voltage bias (-700V) across the pCVD diamond to generate a measurable current (~9 µA) upon interaction with charged particle bunches.
  • Signal Characteristics: Demonstrates an ultra-fast response time (~13 ns) and low charge collection (~90 fC), suitable for precision beam profile measurements.
  • Beam Profiling Capability: Successfully resolved a Gaussian beam profile with a sigma of approximately 625 µm to 841 µm, validating spatial resolution for beam diagnostics.
  • Electronic Integration: Coupled with high-speed transimpedance amplifiers (e.g., Cividec System) and advanced readout electronics (QIE10, Arria V FPGA) for real-time data acquisition.
  • Charge Calibration: Validated across a wide dynamic range (10 fC to 350 pC) using a Sub-Femtoamp current source, ensuring linearity and accuracy.
  • Key Value Proposition: pCVD diamond serves as a radiation-hard, fast-timing alternative to traditional scintillators or silicon detectors for harsh beamline environments.
ParameterValueUnitContext
Detector MaterialPolycrystalline CVD (pCVD) Diamond-Radiation-hard beam monitor
High Voltage Bias-700VOperational bias for charge collection
Detector Current~9µAMeasured signal current
Response Time~13nsPulse rise/fall time
Collected Charge~90fCPer bunch interaction
Beam Profile Sigma 1625.108µmpCVD Diamond Detector Evaluation (18/08/2015)
Beam Profile Sigma 2841.837µmPMT and Acquisition system reference
Beam Speed1.1327m/sCalculated beam velocity
Pressure (Vacuum)1.6 x 10-3PaOperating environment (mPa range implied)
Pressure (Vacuum)4.5 x 10-5mbarOperating environment
Amplifier TypeCividec System / Transimpedance-Front-end signal conditioning
Cable TypeCK50 (80m) Long Cable-Signal transmission to scope
Charge Sweep Range10 fC to 350 pC-QIE10-CH2 dynamic range
QIE10 SubRange 0 Sensitivity3.2fC/binLowest charge resolution
QIE10 SubRange 3 Sensitivity12.5pC/binHighest charge resolution
Current SourceKeithley 6430 Sub-Femtoamp-Precision calibration source
Max TemperatureTmax°CSystem thermal limit
  1. Detector Fabrication: Prepared a polycrystalline CVD (pCVD) diamond substrate suitable for high-voltage biasing and radiation tolerance.
  2. Vacuum Integration: Installed the detector within a stepped vacuum magnetic stopper environment, operating at ultra-high vacuum (1.6 mPa / 4.5 x 10-5 mbar).
  3. Optical Alignment: Employed X/Y axis optical position sensors and barrel motors/resolvers for precise spatial positioning relative to the particle beam.
  4. Signal Readout: Connected the diamond detector to a transimpedance amplifier via a long CK50 (80m) cable, routing the signal to an oscilloscope for raw data capture.
  5. Charge Calibration: Utilized a Sub-Femtoamp Keithley 6430 current source and GPIB-USB-HS interface to sweep charge from 10 fC to 350 pC, calibrating the QIE10 ADC scheme.
  6. Beam Profiling: Captured raw detector signals and processed the charge distribution to fit a Gaussian beam profile, determining the beam sigma and spatial characteristics.
  7. Data Acquisition Architecture: Deployed a VME FMC Carrier Board featuring an Arria V FPGA, Igloo2 GBTx, and TTC system for high-speed, synchronized data readout.
  • Applicable Materials: This research relies on high-grade Polycrystalline Diamond (PCD) capable of sustaining high bias voltages (-700V) while delivering rapid response times (~13 ns). 6CCVD’s Optical Grade and Radiation-Hard PCD wafers are ideally suited to replicate or extend this beam monitoring research, offering consistent charge collection and radiation tolerance.
  • Customization Potential: The detector geometry, active area dimensions, and metalization contacts (e.g., Ti/Pt/Au or W/Cu for high-voltage biasing) are critical to detector performance. 6CCVD provides custom metalization and laser cutting services to deliver application-specific PCD detector plates up to 125mm in diameter. We can tailor thickness from 0.1 µm to 500 µm to optimize signal-to-noise ratios and charge collection efficiency.
  • Thickness Engineering: For particle detector applications requiring fast timing (nanosecond regime), controlling the bulk thickness is essential. 6CCVD’s precision in delivering ultra-thin PCD membranes down to 0.1 µm enables reduced carrier transit times, while thicker plates (up to 500 µm) maximize charge yield for high-energy particle interactions.
  • Surface Polishing: Detector-grade surfaces require minimizing surface charge trapping and ensuring uniform electric field distribution. 6CCVD achieves surface roughness Ra < 5nm on inch-size PCD, directly contributing to stable detector current output and reduced leakage noise under high vacuum.
  • Engineering Support: Navigating the complexities of bias voltage, charge collection dynamics, and front-end electronics integration demands specialized material expertise. 6CCVD’s in-house PhD engineering team is available to consult on material selection, metalization stack design, and vacuum compatibility for beam diagnostics, particle physics, and radiation detection projects.
  • Call to Action: For custom detector specifications, specialized metalization, or material consultation on your next high-energy physics project, visit 6ccvd.com or contact our engineering team directly.
View Original Abstract

A secondary particle shower acquisition system is under design for the upgrade of CERN’s beam wire scanners. The system needs to be capable of performing bunch-by-bunch synchronous measurements with an integration time of 25 ns and to cope with signal variations of up to 6 orders of magnitude. The whole dynamic range should be covered by the acquisition system with a single configuration and should have no tuneable parameters. The secondary particles are detected using a polycrystalline diamond detector with the signal digitization performed nearby with a custom front-end system, designed to resist a total ionising radiation dose up to 1 kGy in 10 years. The digital data transmission, front-end synchronization and control are performed through a bi-directional optical link operating at 4.8 Gbps using CERN’s GBT protocol. For the digitization, two radiation tolerant integrator ASICs (ICECAL and QIE10) are under study.