Skip to content

Motion Control and Optical Interrogation of a Levitating Single Nitrogen Vacancy in Vacuum

MetadataDetails
Publication Date2018-05-17
JournalNano Letters
AuthorsGerard P. Conangla, Andreas W. Schell, Raúl A. Rica, Romain Quidant
InstitutionsInstitute of Photonic Sciences, Institució Catalana de Recerca i Estudis Avançats
Citations76
AnalysisFull AI Review Included
  • Research Focus: Demonstrates the first-ever levitation of a nanodiamond hosting a single Nitrogen-Vacancy (NV) center in high vacuum (down to 10-3 mbar) using an end-cap Paul trap, avoiding the optical absorption heating that plagues conventional optical levitation.
  • Key Technical Achievement: Successfully combines a Paul trap architecture with active parametric feedback cooling to reduce the effective center-of-mass (COM) temperature of the levitated nanodiamond by a factor of 4 (6 to 9 dB energy reduction).
  • Operational Parameters: Trapping voltages range from 0.75 kVpp to 2 kVpp at a 20 kHz driving frequency, maintaining particle stability with calculated Q-factors exceeding 103.
  • Optical Interrogation: Achieved stable fluorescence rates of 2,000-7,000 counts per second using 1-3 mW of 532 nm excitation, successfully identifying single NV emitters via g(2)(0) < 0.5.
  • Cooling Performance: Parametric feedback cooling yields effective COM temperatures between 38 K and 75 K at pressures ranging from 10-2 to 10-1 mbar.
  • Strategic Significance: Establishes a foundational platform for coupling internal spin states to external mechanical motion, enabling future ultra-sensitive quantum sensing and matter-wave interferometry.
  • Material Challenge Highlighted: Authors note “photo-degradation” and “shrinking of the nanodiamonds” at the lowest tested pressures, indicating a critical need for exceptionally pure, low-absorption, high-thermal-stability single crystal diamond.
ParameterValueUnitContext
Particle Diameter40nmCommercial Adámas nanodiamonds
Trapping MechanismPaul Trap (End-cap)-Electric field levitation (no optical trapping force)
Driving Frequency (ω/2π)20kHzRF driving signal
Voltage Amplitude (V0)0.75 - 2.0kVppOperating range; limit set by Paschen’s law (750 Vpp minimum breakdown)
Pressure Range10-3 - 1.0mbarHigh vacuum to ambient transition
Effective Temperature (COM)38 - 75KAchievable via parametric feedback cooling
Q-factor>103-At lowest achievable pressures
Excitation Laser532nmCW laser for NV interrogation
Excitation Power1 - 5mWFluorescence count rates: 2,000-7,000 counts/s
Detection Laser980nmWeak scattering illumination for QPD motion tracking
Fluorescence Collection NA0.8-Olympus LMPLFLN 100x objective
Secular Frequency (Axial)~1.5 - 6kHzTypical range observed at 750 Vpp
Charge Range (Particle)40 - 150e+Elementary charge units
Energy Reduction6 - 9dBFeedback cooling efficiency
  1. Particle Preparation: 20 µl of 40 nm commercial nanodiamond suspension (1-4 NV/particle) dispersed in 40 ml ethanol; sonicated for 10 minutes; filtered using a 100 nm pore syringe filter to prevent clustering.
  2. Loading Mechanism: Custom electrospray system with a 3 kV voltage source injects charged nanodiamonds into the chamber at ambient pressure; excess particles pushed out via careful voltage reduction until a single particle remains.
  3. Paul Trap Configuration: Two assembled steel electrodes separated by 1.4 mm mounted on a ceramic holder and a 3-axis piezoelectric stage. Two additional rods serve as compensation electrodes to eliminate stray fields and minimize micromotion.
  4. Drive Electronics: High voltage signal generated by an FPGA card and a Matsusada AMT-1B60 high voltage amplifier, producing an adjustable sinusoidal output (20 kHz, 0.75-2 kVpp).
  5. Optical Setup: 980 nm scattering laser for motion tracking; 532 nm excitation laser directed through a high-NA (0.8) microscope objective for NV fluorescence collection, filtered, and routed to an EMCCD, spectrometer, or HBT-configured single photon detectors.
  6. Vacuum Sequence: Voltage amplitude held below 750 Vpp during pump-down to avoid plasma ignition per Paschen’s law; amplitude increased once pressure drops below 5·10-1 mbar.
  7. Feedback Cooling Loop: Particle position extracted via a quadrant photodiode (QPD); FPGA computes the product Vi(t)·V̇i(t) to modulate the driving voltage amplitude at frequency 2Ωi, effectively damping the COM oscillation.
  8. Single NV Verification: Hanbury Brown-Twiss (HBT) autocorrelation measurements; single photon emitter confirmed when g(2)(0) < 0.5, with typical g(2)(0) values of 0.4 ± 0.1.
  • Applicable Materials:

    • Optical Grade Single Crystal Diamond (SCD): For replicating the 40 nm NV-center host particles, high-purity SCD with engineered nitrogen-vacancy centers via electron irradiation and annealing is essential. Our SCD material supports Ra < 1nm surface finishing, critical for minimizing optical scattering and maximizing fluorescence collection efficiency.
    • High-Thermal-Stability PCD: Given the authors’ documented challenge of “shrinking” and photo-degradation at low pressures, our thermally robust polycrystalline diamond provides an alternative substrate for levitated optomechanics platforms that demand superior heat dissipation.
  • Customization Potential:

    • Sub-Micron Particle Sourcing: We supply diamond substrates down to 0.1 µm thickness, enabling fabrication or precision sizing of nanoscale levitated diamond specimens tailored to specific mass and charge requirements.
    • Custom Geometries: While the paper uses spherical 40 nm particles, future iterations (as the authors note) will benefit from elongated nanodiamonds whose birefringence enables rotational control. 6CCVD offers custom dimensions and laser cutting services to produce non-standard diamond morphologies for advanced optomechanical experiments.
    • Surface Engineering: Our sub-nanometer polishing capability (Ra < 1nm for SCD) ensures low optical absorption and minimal surface defect-induced heating, directly addressing the thermal bottleneck that limits vacuum-level performance.
  • Engineering Support:

    • Our in-house PhD engineering team can assist with material selection for quantum sensing, levitated optomechanics, and NV-magnetometry platforms. We provide consultation on nitrogen-doping concentration, vacancy engineering protocols, and crystal orientation to optimize spin coherence times and fluorescence yield for your specific application.
    • For research requiring integrated electrodes or microwave antenna structures (the authors explicitly call for a “microwave antenna in the trap” for spin control), 6CCVD’s metalization capabilities (Ti, Pt, Au, W, Cu) enable monolithic device fabrication on diamond substrates.
  • Call to Action: For custom specifications or material consultation, visit 6ccvd.com or contact our engineering team directly.

View Original Abstract

Levitation optomechanics exploits the unique mechanical properties of trapped nano-objects in vacuum to address some of the limitations of clamped nanomechanical resonators. In particular, its performance is foreseen to contribute to a better understanding of quantum decoherence at the mesoscopic scale as well as to lead to novel ultrasensitive sensing schemes. While most efforts have focused so far on the optical trapping of low-absorption silica particles, further opportunities arise from levitating objects with internal degrees of freedom, such as color centers. Nevertheless, inefficient heat dissipation at low pressures poses a challenge because most nano-objects, even with low-absorption materials, experience photodamage in an optical trap. Here, by using a Paul trap, we demonstrate levitation in vacuum and center-of-mass feedback cooling of a nanodiamond hosting a single nitrogen-vacancy center. The achieved level of motion control enables us to optically interrogate and characterize the emitter response. The developed platform is applicable to a wide range of other nano-objects and represents a promising step toward coupling internal and external degrees of freedom.