Skip to content

Coherent quantum control of nitrogen-vacancy center spins near 1000 kelvin

MetadataDetails
Publication Date2019-03-22
JournalNature Communications
AuthorsGang‐Qin Liu, Xi Feng, Ning Wang, Quan Li, Ren‐Bao Liu
InstitutionsChinese University of Hong Kong
Citations151
AnalysisFull AI Review Included
  • Breakthrough in Quantum Sensing: Demonstrates coherent quantum control of Nitrogen-Vacancy (NV) center electron spins in nanodiamonds at temperatures approaching 1000 K, shattering the previous ~700 K limit caused by fluorescence quenching.
  • Innovative Thermal Management: Utilizes pulsed 808 nm NIR laser heating of amorphous carbon films combined with rapid diffusion cooling (~2 µs cooling time) to achieve ultrafast temperature cycling while preserving spin coherence.
  • High-Temperature ODMR (HiT-ODMR): Novel protocol separates spin initialization/readout (at room temperature) from spin manipulation (at elevated temperatures), bypassing the loss of spin-dependent fluorescence.
  • Spin Coherence Validation: Rabi oscillations persist up to 938 K with no significant change in coherence time, validating the robustness of quantum control at extreme temperatures.
  • Nano-Magnetometry Milestone: Observes the magnetic phase transition of a single nickel nanoparticle at a Curie temperature of 615 ± 4 K—a previously inaccessible regime for quantum sensors.
  • Sensitivity Achievement: Estimated temperature sensitivity of approximately 250 mK·Hz-1/2 at 1000 K, based on ODMR parameters and ZFS thermal shift.
  • Practical Impact: Enables nano-thermometry and nano-magnetometry in fields such as thermoremanent magnetization studies, heat-assisted magnetic recording, and thermo-plasmonics, where relevant temperatures exceed 500 K.
ParameterValueUnitContext
Maximum Operating Temperature1004 ± 24KHighest temperature with observable ODMR signal
Previous Temperature Limit~700KPrior constraint due to fluorescence quench
Zero-Field Splitting (ZFS) at 300 K~2.87GHzGround-state splitting between ms=0 and ms=±1
ZFS Shift Rate (near RT)−74kHz·K-1Temperature-dependent frequency shift
ZFS Shift Rate (high T, extracted)~240kHz·K-1Used for temperature sensitivity estimate
Heating Laser Wavelength808nmNIR laser for carbon film absorption
Heating Pulse Duration5µsStandard operational heating time
Rising/Cooling Time~2µsHeat diffusion rate through carbon film
MW Pulse Duration~30nsSpin manipulation timing
Green Laser Wavelength532nmSpin initialization and readout
Green Laser Pulse Duration3µsInitialization/readout pulse
External Magnetic Field38GaussField applied to split NV resonances
Spin Relaxation Time (RT, saturated)~100µsLimited by electric/magnetic noise in NDs
Spin Relaxation Model FitT1-1 = ATn, n = 5.6 ± 0.5—Close to two-phonon Raman process (T5)
Photon Count Rate~8Mcps (Mcounts/s)Used in sensitivity estimation
ODMR Linewidth~10MHzDominated by local charge/strain broadening
ODMR Contrast (at 1000 K)~5%Spin-dependent fluorescence contrast
Temperature Sensitivity~250mK·Hz-1/2Estimated at 1000 K
Curie Temperature (Ni NP)615 ± 4KMagnetic phase transition observed
ODMR Frequency Range Observed2758 - 2880MHzZFS shift range across temperatures
Sample EnvironmentArgon gas chamber—Sealed to prevent carbon film oxidation
  1. Nanodiamond Preparation: NDs containing NV centers deposited onto amorphous carbon films supported on TEM copper grids; samples sealed in argon atmosphere to prevent oxidation during laser heating.
  2. Rapid Laser Heating: Application of 808 nm NIR laser pulses absorbed by the carbon film, heating NDs to target temperatures within ~2 µs.
  3. Rapid Diffusion Cooling: Heat dissipation through the carbon film upon laser switch-off, achieving cooling times of ~2 µs.
  4. HiT-ODMR Pulse Sequence:
    • P (Polarize): Weak 532 nm laser pulse (~3 µs) initializes NV centers to ms=0 at room temperature.
    • H (Heat): Strong 808 nm NIR laser pulse (~5 µs) rapidly elevates ND temperature.
    • MW (Manipulate): Short microwave pulse (~30 ns) applied at the end of the heating pulse for coherent spin control.
    • Cool: Fixed cooling period (~3 µs) allows ND to return to near room temperature.
    • R (Readout): Weak 532 nm laser pulse reads out spin-dependent fluorescence.
  5. Temperature Calibration:
    • For T < 700 K: Use established D(T) relation.
    • For T > 700 K: Extrapolate from exponential cooling dynamics measured at sub-700 K waiting times.
  6. Spin Relaxation Measurement: Two-unit differential protocol comparing fluorescence with/without MW π pulse to isolate spin signals from charge dynamics.
  7. Rabi Oscillation Characterization: MW driving applied after temperature saturation (with NIR laser maintained) to verify coherent spin control at high T.
  8. Nano-Magnetometry: ND sensor positioned near single Ni nanoparticle; ODMR splitting and broadening monitored across temperature cycles to detect magnetic phase transition.

This landmark research on high-temperature NV quantum sensing aligns directly with several specialized offerings. Below is a detailed alignment between the paper’s requirements and available capabilities.

Requirement in PaperRecommended 6CCVD MaterialRationale
NV-center-containing nanodiamondsOptical Grade Single Crystal Diamond (SCD) and Polycrystalline Diamond (PCD)High-purity CVD diamond with engineered NV centers is essential for quantum coherence experiments. Optical grade SCD provides the lowest strain and narrowest ODMR linewidths.
Nanoscale sensing platformsNanodiamond powders (derived from SCD/PCD milling)Enables deposition onto carbon films for the demonstrated high-T sensing architecture.
High-temperature stability substratesSCD/PCD plates (0.1 µm - 500 µm thickness)Diamond’s exceptional thermal stability and conductivity make it ideal for extreme-temperature quantum experiments.
  • Substrate Dimensions: The paper utilized NDs on TEM grids, but extending this work to bulk SCD/PCD sensors (up to 125 mm diameter for PCD, 10 mm substrates) is fully supported.
  • Metalization Options: For integration into device architectures (e.g., microwave striplines for spin manipulation), Au, Pt, Pd, Ti, W, and Cu metalization are available as in-house services.
  • Laser Cutting & Shaping: Custom geometries and nanopatterning support can be provided to fabricate tailored sensor platforms.
  • Boron-Doped Diamond (BDD): For experiments requiring conductive diamond elements or alternative spin bath engineering, heavy boron-doped PCD is offered.
  • Surface Polishing: Ultra-smooth surfaces (Ra < 1 nm for SCD, < 5 nm for inch-size PCD) ensure minimal surface-induced charge noise, critical for narrow ODMR linewidths and high temperature sensitivity.

The in-house PhD-level engineering team is equipped to assist with:

  • Material Selection: Choosing the optimal diamond grade (SCD vs. PCD, NV density, isotopic purity) for specific high-temperature quantum sensing applications.
  • Sensor Architecture Design: Consultation on integrating diamond sensors with heating substrates, microwave delivery structures, and optical readout paths.
  • Process Optimization: Guidance on diamond surface functionalization, metalization stack design, and packaging for extreme environments.
  • Prototype Fabrication: Rapid turnaround on custom diamond substrates and sensor elements for proof-of-principle and publication-quality experiments.

This research directly addresses high-temperature nano-thermometry and nano-magnetometry—applications with commercial and scientific demand in:

  • Heat-Assisted Magnetic Recording (HAMR) media characterization
  • Thermo-plasmonics of metallic nanoparticles
  • Magnetic phase transition studies in single nanoparticles
  • Thermoelectric nanostructure characterization
  • Petrology and planetary science (thermoremanent magnetization)

For custom specifications or material consultation, visit 6ccvd.com or contact our engineering team directly.

View Original Abstract

Quantum coherence control usually requires low temperature environments. Even for nitrogen-vacancy center spins in diamond, a remarkable exception, the coherence signal is limited to about 700 K due to the quench of the spin-dependent fluorescence at a higher temperature. Here we overcome this limit and demonstrate quantum coherence control of the electron spins of nitrogen-vacancy centers in nanodiamonds at temperatures near 1000 K. The scheme is based on initialization and readout of the spins at room temperature and control at high temperature, which is enabled by pulse laser heating and rapid diffusion cooling of nanodiamonds on amorphous carbon films. Using the diamond magnetometry based on optically detected magnetic resonance up to 800 K, we observe the magnetic phase transition of a single nickel nanoparticle at about 615 K. This work enables nano-thermometry and nano-magnetometry in the high-temperature regime.