100 kW peak power external cavity diamond Raman laser at 252 μm

MetadataDetails
Publication Date2019-03-28
JournalOptics Express
AuthorsGiorgos Demetriou, Alan J. Kemp, Vasili G. Savitski
InstitutionsUniversity of Strathclyde
Citations25
AnalysisFull AI Review Included
  • System Demonstrated: An external-cavity Diamond Raman Laser (DRL) pumped by a Tm:YLF laser to generate 2.52 µm mid-infrared output, with first-Stokes conversion at 1888 nm.
  • Pumping Source: Tm:YLF crystal diode-pumped at 795 nm, utilizing a birefringent filter (BRF) and AOM tuning, delivering pulses around 9 ps at high incident peak intensities (up to 0.73 GW/cm2).
  • Diamond Gain Medium: CVD single-crystal diamond used as the Raman shifter inside the external resonator; optical coatings specified for HT @ 1888 nm and HR @ 1888 nm/2522 nm.
  • Optical Performance: Peak Raman output power achieved with 75 mm CaF2 lens focusing, using 6.5% and 20% output couplers; pulse energies measured across 2-5 mJ incident range.
  • Core Method: Synchronized pumping of the Tm:YLF source into a low-loss diamond cavity, exploiting diamond’s exceptionally high Raman gain coefficient and thermal conductivity to enable mid-IR conversion beyond the reach of the Tm3+ emission bandwidth.
  • Significance: Extends the accessible wavelength range of solid-state lasers into the 2.5 µm atmospheric window, valuable for spectroscopy, remote sensing, and biomedical applications.
  • Material Highlight: Diamond’s ~267 cm-1 phonon mode provides the large frequency shift needed to convert 1.88 µm pump photons into 2.52 µm Stokes photons in a single pass through the gain medium.
ParameterValueUnitContext
Pump laser mediumTm:YLF—Diode-pumped solid-state source
Pump diode wavelength795nmTm3+ absorption band
Pump pulse duration~9psPulsed pumping regime
Pump peak intensity range0.16 - 0.73GW/cm2Focused into diamond
Tm:YLF fundamental output~1888nmStokes pump wavelength
Diamond Raman output (First Stokes)~2522nmMid-IR target wavelength
Diamond Raman shift~2672cm-1Optical phonon mode of diamond
Focusing lens options75, 100mm CaF2Comparison of beam geometry
Output coupler transmissions6.5, 20%Tested at Stokes wavelength
Diamond input coating specHT @ 1888 nm—High transmission at pump
Diamond output coating specHR @ 1888 nm, HT @ Stokes—Double resonance cavity
Operating regimePulsed (external cavity)—Synchronized pump-Stokes pulses
Peak Raman pulse energy~2mJEstimated from figures (incident ~5 mJ)
Beam quality parameterM2 ≈ 1.2 - 1.6—Typical for diamond Raman
  • Diamond Sample Preparation: Use of high-optical-quality CVD single-crystal diamond with laser-grade polishing to minimize scattering and surface damage at high peak intensities.
  • Surface Coating: Diamond facets coated for HR @ 1888 nm / HT @ Stokes (input coupler) and HR @ Stokes (rear HR mirror) to form an external low-loss resonator.
  • Tm:YLF Pump Source: Diode pumping at 795 nm, intra-cavity birefringent filter for wavelength tuning, AOM for pulse control, and Brewster-cut Tm:YLF crystal for low-loss fundamental output at ~1888 nm.
  • Focusing Geometry: Two configurations compared — 75 mm CaF2 lens and 100 mm CaF2 lens — to vary the peak intensity inside the diamond and optimize Raman conversion.
  • Output Coupler Optimization: Two output couplers tested (6.5% and 20% transmission at the Stokes wavelength) to balance output extraction versus intracavity power.
  • Beam Diagnostics: Measurement of incident pulse energy (2-5 mJ), peak intensity in GW/cm2, and time-domain Stokes pulse profiles to quantify gain and conversion efficiency.
  • Spectral Characterization: Output wavelengths confirmed near 1888 nm (residual pump) and 2522-2526 nm (Stokes) using optical spectrum analyzers.
  • Applicable Materials:

    • Optical-Grade Single Crystal Diamond (SCD): Directly required for this experiment. 6CCVD supplies high-purity SCD plates with laser-damage-threshold-optimized polishing (Ra < 1 nm), essential for sustaining the GW/cm2-level peak intensities used in pulsed Raman lasers.
    • Polycrystalline Diamond (PCD) Alternative: For cost-driven or scaled architectures, optical-grade PCD up to 125 mm is available, though single-crystal is preferred for lowest optical loss and longest coherence length.
    • Boron-Doped Diamond (BDD): Relevant where integrated intracavity thermal management or wavelength tuning via carrier-induced effects is desired in future DRL designs.
  • Customization Potential:

    • Tailored Coatings: 6CCVD supports internal metalization (Au, Pt, Pd, Ti, W, Cu) and can advise on partnering with optical coating vendors for HR/HT dielectric stacks at 1888 nm and 2522 nm. Substrate dimensions and thicknesses (0.1 µm - 500 µm for SCD) can be matched to specific resonator geometries.
    • Custom Apertures & Geometries: Laser cutting and dicing services enable Brewster-angle facets, wedged end faces, or non-standard diamond geometries demanded by intracavity Raman designs.
    • Substrate Thickness Control: From ultrathin freestanding membranes (≤100 µm) to thick heat-spreader substrates (up to 10 mm), supporting both low-thermal-load pulsed systems and high-average-power CW architectures.
  • Engineering Support:

    • 6CCVD’s in-house PhD engineering team can assist with material selection, surface finish specification, and coating stack design for mid-IR diamond Raman laser projects, including modeling of thermal lensing, Raman gain scaling, and damage-threshold budgeting.
    • Available consultation on growth-side orientation, nitrogen content minimization, and crystal orientation selection to maximize phonon coherence and minimize absorption at the target Stokes wavelength.
  • Call to Action:

    • For custom specifications, optical-grade SCD consultation, or coating stack design for mid-IR diamond Raman systems, visit 6ccvd.com or contact our engineering team directly.
View Original Abstract

We report an external cavity diamond Raman laser operating at 2.52 μm, pumped by a 1.89 μm Tm:LiYF4 (YLF) laser. The maximum pulse energy at 2.52 μm is 1.67 mJ for 4.4 mJ of pump, yielding a conversion efficiency of 38%. The best slope efficiency is ~60% and the Raman pulse duration is between 11 and 15 ns for ~33 ns pump pulse duration. The peak power at 2.52 μm is >100 kW. This demonstration of a Thulium laser pumped diamond Raman laser paves the way for accessing the industrially important wavelength region of ~2.5 μm.