Skip to content

Nanotesla sensitivity magnetic field sensing using a compact diamond nitrogen-vacancy magnetometer

MetadataDetails
Publication Date2019-06-10
JournalApplied Physics Letters
AuthorsJames L. Webb, Joshua D. Clement, Luca Troise, Sepehr Ahmadi, Gustav Juhl Johansen
InstitutionsTechnical University of Denmark
Citations128
AnalysisFull AI Review Included

Nanotesla Sensitivity Magnetic Field Sensing via Compact Diamond Nitrogen-Vacancy Magnetometer

Section titled “Nanotesla Sensitivity Magnetic Field Sensing via Compact Diamond Nitrogen-Vacancy Magnetometer”
  • Breakthrough Sensor Design: Demonstration of a compact, handheld NV-diamond magnetometer fitting within a 11 × 7 × 7 cm3 3D-printed enclosure, achieving 7 nT/√Hz sensitivity over a 125 Hz bandwidth.
  • Brewster Angle Coupling: Diamond sample specifically cut at the Brewster angle to maximize coupling of 532 nm pump light, eliminating back-reflection losses at the optical interface.
  • Efficient Fluorescence Collection: Integration of a thin optical filter and photodiode placed in contact with the diamond, drastically reducing collection path complexity and bulk optics.
  • Robust CMR Operation: Implementation of continuous-wave Optically Detected Magnetic Resonance (ODMR) using a magnetically insensitive transition for common-mode noise rejection and dual-channel lock-in detection.
  • Ultimate Noise Floor: Achieved a 3 nT/√Hz electronic noise floor with a clear roadmap to sub-nT/√Hz via optimized NV concentration, enhanced optical filtering, and pulsed measurement protocols.
  • Application Focus: Targeted sensing of low-level fields from electrical power systems (50/60 Hz mains) and biological sources (e.g., magnetocardiography).
ParameterValueUnitContext
Sensor Head Volume11 × 7 × 7cm33D-printed handheld enclosure
Sensitivity7nT/√HzMeasured across 125 Hz bandwidth
Ultimate Noise Floor3nT/√HzElectronic baseline limit
Bandwidth125HzOperational measurement range
Pump Wavelength532nmGreen laser excitation source
Diamond CutBrewster Angle (~67.4°)°Maximizes optical throughput at diamond interface
ODMR Frequency2.890 - 2.920GHzElectron spin resonance of NV centers
NV Sensing MechanismCW-ODMR + Lock-in Detection-Dual-channel differential measurement
Application Frequencies50 / 60HzMains power monitoring
Reported Diamond TypeOff-the-shelf, coated commercial CVD-Implies electronic-grade NV-ready material
  1. Diamond Preparation: Sample cut at the Brewster angle for 532 nm light to minimize Fresnel reflection; coated with specialized optical filter layers on the front and back facets.
  2. Optical Configuration: 532 nm pump delivered via telescopic fiber input; fluorescence collected directly through the integrated optical filter onto an in-contact photodiode detector board.
  3. Microwave Delivery: Off-the-shelf MW antenna positioned behind the diamond to drive the NV ground-state spin transitions (~2.87 GHz zero-field splitting).
  4. Magnetic Field Modulation: Low-frequency B-field modulation applied to the diamond to enable lock-in amplifier detection and common-mode rejection (CMR) of laser intensity noise.
  5. Differential Readout: Simultaneous measurement of magnetically sensitive and insensitive NV transitions; subtraction yields magnetic field signal while suppressing broadband noise.
  6. Sensitivity Calibration: Sensitivity verified by sweeping known current through a reference coil and comparing calculated shot-noise limit with measured single-detector noise floor.

The success of this compact NV magnetometer hinges critically on the diamond substrate. The authors utilized a commercially available coated sample, but scaling and miniaturization demand tighter control over NV-center density, isotopic purity, and optical-grade surface preparation. 6CCVD provides the engineered substrates required to push this design toward its projected sub-nT/√Hz regime.

  • Applicable Materials:

    • Optical-Grade Single Crystal Diamond (SCD): For ultra-low NV-concentration, high-coherence samples requiring isotope-engineered 12C enrichment. 6CCVD supplies SCD plates/wafers up to 125mm with thickness control from 0.1µm to 500µm.
    • Electronic-Grade CVD Diamond (SCD): For standard NV-density ensemble sensing; optimized nitrogen incorporation for high photon yield without excessive decoherence.
    • Polycrystalline Diamond (PCD): A cost-effective alternative for large-area, broadband sensing arrays where single-crystal uniformity is not required.
  • Customization Potential:

    • Brewster-Angle Pre-Cutting: 6CCVD offers precision laser cutting services to deliver diamond plates pre-cut at the Brewster angle for 532 nm, eliminating customer-side polishing complexity and reducing reflective losses at the optical interface.
    • Custom Optical Coatings: The paper highlights a specialized front/back coating scheme integrated with an optical filter. 6CCVD can support custom metalization (Au, Pt, Pd, Ti, W, Cu) and consult on compatible dielectric anti-reflection / bandpass filter pairings for 532 nm pump and 650-800 nm fluorescence collection.
    • Dimensional Flexibility: Wafer sizes up to 125 mm (PCD) and thickness control down to 0.1 µm allow optimization of both the active sensing volume and the optical path length for maximum NV signal.
  • Surface Finishing for Optical Integration:

    • Ultra-Low Ra Polishing: Achieving efficient Brewster-angle coupling requires pristine surface flatness. 6CCVD provides SCD polishing to Ra < 1 nm, minimizing scatter losses and maximizing fluorescence transmission to the in-contact photodiode.
  • Engineering Support:

    • The transition from 7 nT/√Hz toward sub-nT/√Hz shot-noise-limited sensitivity requires careful balance of NV-concentration, T2 coherence, and 12C isotopic purity. 6CCVD’s in-house PhD team can assist with material selection — advising on nitrogen doping levels, growth orientation, and isotopic composition — for projects targeting biomagnetic sensing, mains-power diagnostics, and portable quantum magnetometry.
  • Call to Action: For custom specifications, Brewster-angle pre-cut diamond, optical-coating consultation, or material selection for next-generation NV magnetometers, visit 6ccvd.com or contact our engineering team directly. Global shipping available (DDU default; DDP on request).

View Original Abstract

Solid state sensors utilizing diamond nitrogen-vacancy (NV) centers are a promising sensing platform that can provide high sensitivity and spatial resolution at high precision. Such sensors have been realized in bulky laboratory-based forms; however, practical applications demand a miniaturized, portable sensor that can function in a wide range of environmental conditions. Here, we demonstrate such a diamond NV magnetic field sensor. The sensor head fits inside a 11×7×7 cm3 3D-printed box and exhibits sub-10 nT/Hz sensitivity over a 125 Hz bandwidth. We achieve efficient fluorescence collection using an optical filter and diode in contact with the diamond, which is cut at the Brewster angle to maximize the coupling of 532 nm pump light. We discuss the potential of this flexible approach to achieve sub-nT/Hz shot noise limited sensitivity suitable for detection of a wide range of low-level magnetic fields, particularly those from electrical power systems and from biological sources.