New dynamic diamond anvil cells for tera-pascal per second fast compression x-ray diffraction experiments
At a Glance
Section titled “At a Glance”| Metadata | Details |
|---|---|
| Publication Date | 2019-06-01 |
| Journal | Review of Scientific Instruments |
| Authors | Zs. Jenei, Hanns‐Peter Liermann, Rachel J. Husband, Alba San José Méndez, David Pennicard |
| Institutions | Goethe University Frankfurt, European Synchrotron Radiation Facility |
| Citations | 52 |
| Analysis | Full AI Review Included |
Executive Summary
Section titled “Executive Summary”- System achievement: Dynamic Diamond Anvil Cells (dDACs) integrated with GaAs LAMBDA photon-counting detectors achieve effective XRD frame rates of up to 4 kHz at beamline P02.2 (PETRA III), enabling fast compression-rate dependent materials research.
- Compression rate benchmarks: Maximum sustained compression rates of ~160 TPa/s (Au, 2.5 ms ramp) and ~56 TPa/s average rate, validated against equation-of-state standards.
- Anvil demand: Experiments utilized standard brilliance/culet anvil pairs (50-300 µm culets) to reach up to ~203 GPa (water, 50 µm culet) and ~152 GPa (Bi/Au, 60 µm beveled anvil), confirming that proper dDAC geometry requires flawless anvils to survive multi-kN forces.
- Detector innovation: GaAs LAMBDA sensor provides ~100% absorption at 25.6 keV, 55 µm pixel pitch, and an Instrumental Resolution Function 3× better than PerkinElmer XRD1621 flat panels.
- Dual-DAC architecture: LLNL designs (1-piezo HPSt 1000/35-25/80 and 3-piezo PSt 1000/16/60 VS25) and ECB designs (PI Ceramic 72-285 and 64-107) bracket the rise-time/force trade space.
- Application span: Demonstrated on high-Z systems (Au, Bi — phase transitions up to Bi-V), low-Z systems (H2O ice VI→VII), and oscillatory compression (1 Hz, 1500 K target) for Earth-science analogs like (Mg0.8Fe0.2)O.
- Roadmap: Future work targets 4th-generation sources (ESRF-EBS, APS-U, PETRA IV) and XFELs (European XFEL HED, AGIPD detectors at 4.5 MHz) for compression rates above 100 TPa/s with low-Z compounds.
Technical Specifications
Section titled “Technical Specifications”| Parameter | Value | Unit | Context |
|---|---|---|---|
| X-ray beam energy | 25.6 | keV | PETRA III P02.2, CRL focused |
| Beam focus (FWHM) | 8 × 2 | µm2 | Compound refractive lens array |
| Detector pixel size | 55 | µm | GaAs LAMBDA Medipix3 hybrid |
| Detector active area | 8.5 × 8.5 | cm × cm | 3 tiled modules, 2.3 megapixels |
| Detector frame rate (single) | 2,000 | Hz | 12-bit mode, zero dead time |
| Detector frame rate (dual, offset) | 4,000 | Hz | 0.25 ms inter-detector delay |
| Detector absorption @ 25.6 keV | ~100 | % | GaAs 500 µm-thick sensor |
| Max compression rate (Au) | 160 | TPa/s | 2.5 ms ramp, 1-piezo LLNL |
| Avg compression rate (Au) | 56 | TPa/s | Derived from EOS of Anderson 1989 |
| Max pressure (Au, 50 µm culet) | ~140 | GPa | Non-hydrostatic deviation ~14.3 GPa |
| Max pressure (H2O, 50 µm culet) | ~203 | GPa | 60 mm ECB piezo, 1000 V |
| Max pressure (Bi) | 152 | GPa | 60 µm beveled anvil, LLNL 1-piezo |
| Max compression rate (Bi) | 121.6 | TPa/s | 2.5 ms ramp |
| Max pressure (H2O, 300 µm culet) | 110 | GPa | 0.8 GPa/s, 90 mm ECB piezo |
| Initial pre-compression (Bi) | 3 | GPa | Stainless gasket, 15 µm thick |
| Anvil force limit | 15-16 | kN | Just before diamond failure |
| Diamond anvil culet range | 50-300 | µm | Standard symmetric & LLNL membrane DACs |
| Gasket materials | Re, Stainless Steel | — | Re stable above 1 Mbar |
| Pre-indented gasket thickness | 20-25 | µm | For 50-300 µm culets |
| Oscillation frequency | 1 | Hz | Ferropericlase (Mg0.8Fe0.2)O experiment |
| Target heating (future) | 1500 | K | Resistively-heated dDAC, vacuum |
| IRF (FWHM) vs XRD1621 | 3× better | — | CeO2 NIST 647b standard |
| Optical opening angle (DAC) | ± 28 | ° | c-BN / WC seats |
| X-ray opening angle (DAC) | ± 35 | ° | ECB piston-cylinder DAC |
| Camera length (SDD) | ~425.7 | mm | Q range = 2 to 4.6 Å-1 |
| Q range recorded | 2 - 4.6 | Å-1 | Au (111) and (200) reflections |
| Piezo Actuator | Capacitance (µF) | Blocking Force (kN) | Length (mm) | Hollow Bore (mm) | Min Rise Time @ 7 A (ms) |
|---|---|---|---|---|---|
| 72-285 (ECB small) | 7.46 | 71 | 60 | 9 | 1.60 |
| 64-107 (ECB large) | 11 / 16.5 | 71 | 90 | 9 | 2.36 / 2.50 |
| HPSt 1000/35-25/80 (LLNL 1-piezo) | 1.3 | 20 | 72 | 25 | 0.279 / 0.340 |
| 3× PSt 1000/16/60 VS25 (LLNL) | 1.62 | 36 | 71 | — | 0.347 / 0.450 |
| Amplifier | Peak Current (A) | Repetition Rate (Hz) | Min Rise Time @ 1 kV (ms) |
|---|---|---|---|
| HV-RCV1000/3 | 3 | 200 | 0.65 - 5.50 |
| HV-RCV1000/7 | 7 | 200 | 0.279 - 2.50 |
| HVP 1000/20 | 20 | 10 | 0.098 - 0.83 |
Key Methodologies
Section titled “Key Methodologies”- Sample loading: Powder (Au, Bi, or H2O) plus optional pressure marker (Au, ruby, or Pt) sealed in a pre-indented Re or stainless-steel gasket (20-25 µm thick) within a symmetric piston-cylinder or LLNL membrane DAC.
- DAC integration: DAC body closed inside a hardened-steel (Type 1.4112 / Vascomax) dDAC housing with the piezo actuator at the upstream end; end cap pre-compresses the piezo and sample.
- Pre-compression step: Apply initial pressure (e.g., 3 GPa for Bi) by tightening the cap or using a co-driven membrane.
- Waveform definition: Use Agilent 33522B arbitrary waveform generator (Benchlink software) to define a trapezoidal or sinusoidal envelope (rise, hold, fall).
- High-voltage amplification: Trigger Piezosystem Jena HV-RCV1000/7 amplifier (7 A peak, 1000 V) to expand the piezo stack/stack array (20 µm nominal) against the DAC piston.
- X-ray illumination: Excite the sample with a 25.6 keV beam focused via Compound Refractive Lenses (CRL) to 8 µm × 2 µm FWHM.
- Photon detection: Acquire XRD frames on two GaAs LAMBDA detectors (2 kHz each, 0.25 ms phase offset → 4 kHz effective), 12-bit mode, with DIOPTAS-based calibration using Cr2O3, Al2O3, and LaB6 standards.
- Timing control: Trigger waveform generator, LAMBDA detectors, and oscilloscope via SRS DG645 delay generator with an Rb clock.
- Pressure determination: Fit Au(111) or Au(200) with Pseudo-Voigt (PeakFit©) and apply Anderson et al. (1989) or Fei et al. (2007) EOS; cross-check with Ruby fluorescence (Dewaele 2004) or diamond Raman (Akahama 2006).
- Data reduction: Automate integration with DIOPTAS and the custom beamline pipeline “P02 Processing Tool” / “P02tool” for 4D (Q-t-P) analysis.
6CCVD Solutions & Capabilities
Section titled “6CCVD Solutions & Capabilities”Applicable Materials
Section titled “Applicable Materials”The beveled standard-cut anvils used in this work (50, 60, 100, 200, and 300 µm culets) sit firmly within our production envelope. For demands up to ~203 GPa with a 50 µm culet, we recommend Optical Grade Single Crystal Diamond (SCD) anvils finished to Ra < 1 nm on the culet face, with paired Boehler-Almax or standard brilliant-cut geometry to maximize the x-ray opening angle (± 35°). When the customer prefers a more forgiving anvil for exploratory ramps or non-hydrostatic loading, Optical Grade Polycrystalline Diamond (PCD) with sub-5 nm polishing is a cost-effective alternative.
For ferropericlase ((Mg0.8Fe0.2)O) and other Earth-science analogs used in future resistively-heated 1500 K dDAC campaigns, Optical Grade SCD remains the optimal choice because its thermal conductivity and Raman signature underpin the Akahama pressure calibration relied upon in this paper.
Customization Potential
Section titled “Customization Potential”- Reverse / beveled anvil geometry: 6CCVD can manufacture standard cut anvils down to 50 µm culets with 0.5°-1.0° bevels, matching the beveled 60 µm anvils used for the 152 GPa Bi compression. Custom seat diameters (c-BN, WC) and gasket centering are also available.
- Wafer / plate dimensions: Plates up to 125 mm (PCD) and SCD thickness ranges of 0.1 µm - 500 µm allow us to supply diamond backplates, heat spreaders, or windows for the dDAC housing and downstream synchrotron beamline instrumentation.
- Metalization & laser cutting: All anvils or backplates used as electrodes or bonded to piezo stacks can be metallized in-house with Ti, Pt, Au, Pd, W, or Cu. Laser cutting allows customer-specific culet sizes, seat geometries, and through-holes (e.g., the 9 mm through-bore required for the ECB piezo stacks) to be produced with ±5 µm tolerance.
- Gasket-grade polycrystalline substrates: For experiments transitioning above 1 Mbar where Re gaskets are preferred, our PCD substrates up to 10 mm thick can be machined as gasket blanks or as optical supports for the LLNL membrane DAC.
Engineering Support
Section titled “Engineering Support”6CCVD’s in-house PhD engineering team can assist with material selection for high-pressure XRD, dynamic compression, and seismic-analog projects. Whether the application demands optical-grade SCD anvils for sub-nanometer surface roughness, heavy boron-doped PCD for in-situ electrical heating variants of the dDAC, or stress-engineered metalized stacks for piezo-coupled assemblies, our team can recommend the optimal grade, geometry, and finishing specification. We can also provide feasibility studies on culet beveling, seat integration, and Au/Ti/Pt metallization schemes to extend the force envelope of next-generation dDACs.
Call to Action
Section titled “Call to Action”For custom specifications or material consultation, visit 6ccvd.com or contact our engineering team directly.
View Original Abstract
Fast compression experiments performed using dynamic diamond anvil cells (dDACs) employing piezoactuators offer the opportunity to study compression-rate dependent phenomena. In this paper, we describe an experimental setup which allows us to perform time-resolved x-ray diffraction during the fast compression of materials using improved dDACs. The combination of the high flux available using a 25.6 keV x-ray beam focused with a linear array of compound refractive lenses and the two fast GaAs LAMBDA detectors available at the Extreme Conditions Beamline (P02.2) at PETRA III enables the collection of x-ray diffraction patterns at an effective repetition rate of up to 4 kHz. Compression rates of up to 160 TPa/s have been achieved during the compression of gold in a 2.5 ms fast compression using improved dDAC configurations with more powerful piezoactuators. The application of this setup to low-Z compounds at lower compression rates is described, and the high temporal resolution of the setup is demonstrated. The possibility of applying finely tuned pressure profiles opens opportunities for future research, such as using oscillations of the piezoactuator to mimic propagation of seismic waves in the Earth.