New dynamic diamond anvil cells for tera-pascal per second fast compression x-ray diffraction experiments

MetadataDetails
Publication Date2019-06-01
JournalReview of Scientific Instruments
AuthorsZs. Jenei, Hanns‐Peter Liermann, Rachel J. Husband, Alba San José Méndez, David Pennicard
InstitutionsGoethe University Frankfurt, European Synchrotron Radiation Facility
Citations52
AnalysisFull AI Review Included
  • System achievement: Dynamic Diamond Anvil Cells (dDACs) integrated with GaAs LAMBDA photon-counting detectors achieve effective XRD frame rates of up to 4 kHz at beamline P02.2 (PETRA III), enabling fast compression-rate dependent materials research.
  • Compression rate benchmarks: Maximum sustained compression rates of ~160 TPa/s (Au, 2.5 ms ramp) and ~56 TPa/s average rate, validated against equation-of-state standards.
  • Anvil demand: Experiments utilized standard brilliance/culet anvil pairs (50-300 µm culets) to reach up to ~203 GPa (water, 50 µm culet) and ~152 GPa (Bi/Au, 60 µm beveled anvil), confirming that proper dDAC geometry requires flawless anvils to survive multi-kN forces.
  • Detector innovation: GaAs LAMBDA sensor provides ~100% absorption at 25.6 keV, 55 µm pixel pitch, and an Instrumental Resolution Function 3× better than PerkinElmer XRD1621 flat panels.
  • Dual-DAC architecture: LLNL designs (1-piezo HPSt 1000/35-25/80 and 3-piezo PSt 1000/16/60 VS25) and ECB designs (PI Ceramic 72-285 and 64-107) bracket the rise-time/force trade space.
  • Application span: Demonstrated on high-Z systems (Au, Bi — phase transitions up to Bi-V), low-Z systems (H2O ice VI→VII), and oscillatory compression (1 Hz, 1500 K target) for Earth-science analogs like (Mg0.8Fe0.2)O.
  • Roadmap: Future work targets 4th-generation sources (ESRF-EBS, APS-U, PETRA IV) and XFELs (European XFEL HED, AGIPD detectors at 4.5 MHz) for compression rates above 100 TPa/s with low-Z compounds.
ParameterValueUnitContext
X-ray beam energy25.6keVPETRA III P02.2, CRL focused
Beam focus (FWHM)8 × 2µm2Compound refractive lens array
Detector pixel size55µmGaAs LAMBDA Medipix3 hybrid
Detector active area8.5 × 8.5cm × cm3 tiled modules, 2.3 megapixels
Detector frame rate (single)2,000Hz12-bit mode, zero dead time
Detector frame rate (dual, offset)4,000Hz0.25 ms inter-detector delay
Detector absorption @ 25.6 keV~100%GaAs 500 µm-thick sensor
Max compression rate (Au)160TPa/s2.5 ms ramp, 1-piezo LLNL
Avg compression rate (Au)56TPa/sDerived from EOS of Anderson 1989
Max pressure (Au, 50 µm culet)~140GPaNon-hydrostatic deviation ~14.3 GPa
Max pressure (H2O, 50 µm culet)~203GPa60 mm ECB piezo, 1000 V
Max pressure (Bi)152GPa60 µm beveled anvil, LLNL 1-piezo
Max compression rate (Bi)121.6TPa/s2.5 ms ramp
Max pressure (H2O, 300 µm culet)110GPa0.8 GPa/s, 90 mm ECB piezo
Initial pre-compression (Bi)3GPaStainless gasket, 15 µm thick
Anvil force limit15-16kNJust before diamond failure
Diamond anvil culet range50-300µmStandard symmetric & LLNL membrane DACs
Gasket materialsRe, Stainless Steel—Re stable above 1 Mbar
Pre-indented gasket thickness20-25µmFor 50-300 µm culets
Oscillation frequency1HzFerropericlase (Mg0.8Fe0.2)O experiment
Target heating (future)1500KResistively-heated dDAC, vacuum
IRF (FWHM) vs XRD16213× better—CeO2 NIST 647b standard
Optical opening angle (DAC)± 28°c-BN / WC seats
X-ray opening angle (DAC)± 35°ECB piston-cylinder DAC
Camera length (SDD)~425.7mmQ range = 2 to 4.6 Å-1
Q range recorded2 - 4.6Å-1Au (111) and (200) reflections
Piezo ActuatorCapacitance (µF)Blocking Force (kN)Length (mm)Hollow Bore (mm)Min Rise Time @ 7 A (ms)
72-285 (ECB small)7.46716091.60
64-107 (ECB large)11 / 16.5719092.36 / 2.50
HPSt 1000/35-25/80 (LLNL 1-piezo)1.32072250.279 / 0.340
3× PSt 1000/16/60 VS25 (LLNL)1.623671—0.347 / 0.450
AmplifierPeak Current (A)Repetition Rate (Hz)Min Rise Time @ 1 kV (ms)
HV-RCV1000/332000.65 - 5.50
HV-RCV1000/772000.279 - 2.50
HVP 1000/2020100.098 - 0.83
  1. Sample loading: Powder (Au, Bi, or H2O) plus optional pressure marker (Au, ruby, or Pt) sealed in a pre-indented Re or stainless-steel gasket (20-25 µm thick) within a symmetric piston-cylinder or LLNL membrane DAC.
  2. DAC integration: DAC body closed inside a hardened-steel (Type 1.4112 / Vascomax) dDAC housing with the piezo actuator at the upstream end; end cap pre-compresses the piezo and sample.
  3. Pre-compression step: Apply initial pressure (e.g., 3 GPa for Bi) by tightening the cap or using a co-driven membrane.
  4. Waveform definition: Use Agilent 33522B arbitrary waveform generator (Benchlink software) to define a trapezoidal or sinusoidal envelope (rise, hold, fall).
  5. High-voltage amplification: Trigger Piezosystem Jena HV-RCV1000/7 amplifier (7 A peak, 1000 V) to expand the piezo stack/stack array (20 µm nominal) against the DAC piston.
  6. X-ray illumination: Excite the sample with a 25.6 keV beam focused via Compound Refractive Lenses (CRL) to 8 µm × 2 µm FWHM.
  7. Photon detection: Acquire XRD frames on two GaAs LAMBDA detectors (2 kHz each, 0.25 ms phase offset → 4 kHz effective), 12-bit mode, with DIOPTAS-based calibration using Cr2O3, Al2O3, and LaB6 standards.
  8. Timing control: Trigger waveform generator, LAMBDA detectors, and oscilloscope via SRS DG645 delay generator with an Rb clock.
  9. Pressure determination: Fit Au(111) or Au(200) with Pseudo-Voigt (PeakFit©) and apply Anderson et al. (1989) or Fei et al. (2007) EOS; cross-check with Ruby fluorescence (Dewaele 2004) or diamond Raman (Akahama 2006).
  10. Data reduction: Automate integration with DIOPTAS and the custom beamline pipeline “P02 Processing Tool” / “P02tool” for 4D (Q-t-P) analysis.

The beveled standard-cut anvils used in this work (50, 60, 100, 200, and 300 µm culets) sit firmly within our production envelope. For demands up to ~203 GPa with a 50 µm culet, we recommend Optical Grade Single Crystal Diamond (SCD) anvils finished to Ra < 1 nm on the culet face, with paired Boehler-Almax or standard brilliant-cut geometry to maximize the x-ray opening angle (± 35°). When the customer prefers a more forgiving anvil for exploratory ramps or non-hydrostatic loading, Optical Grade Polycrystalline Diamond (PCD) with sub-5 nm polishing is a cost-effective alternative.

For ferropericlase ((Mg0.8Fe0.2)O) and other Earth-science analogs used in future resistively-heated 1500 K dDAC campaigns, Optical Grade SCD remains the optimal choice because its thermal conductivity and Raman signature underpin the Akahama pressure calibration relied upon in this paper.

  • Reverse / beveled anvil geometry: 6CCVD can manufacture standard cut anvils down to 50 µm culets with 0.5°-1.0° bevels, matching the beveled 60 µm anvils used for the 152 GPa Bi compression. Custom seat diameters (c-BN, WC) and gasket centering are also available.
  • Wafer / plate dimensions: Plates up to 125 mm (PCD) and SCD thickness ranges of 0.1 µm - 500 µm allow us to supply diamond backplates, heat spreaders, or windows for the dDAC housing and downstream synchrotron beamline instrumentation.
  • Metalization & laser cutting: All anvils or backplates used as electrodes or bonded to piezo stacks can be metallized in-house with Ti, Pt, Au, Pd, W, or Cu. Laser cutting allows customer-specific culet sizes, seat geometries, and through-holes (e.g., the 9 mm through-bore required for the ECB piezo stacks) to be produced with ±5 µm tolerance.
  • Gasket-grade polycrystalline substrates: For experiments transitioning above 1 Mbar where Re gaskets are preferred, our PCD substrates up to 10 mm thick can be machined as gasket blanks or as optical supports for the LLNL membrane DAC.

6CCVD’s in-house PhD engineering team can assist with material selection for high-pressure XRD, dynamic compression, and seismic-analog projects. Whether the application demands optical-grade SCD anvils for sub-nanometer surface roughness, heavy boron-doped PCD for in-situ electrical heating variants of the dDAC, or stress-engineered metalized stacks for piezo-coupled assemblies, our team can recommend the optimal grade, geometry, and finishing specification. We can also provide feasibility studies on culet beveling, seat integration, and Au/Ti/Pt metallization schemes to extend the force envelope of next-generation dDACs.

For custom specifications or material consultation, visit 6ccvd.com or contact our engineering team directly.

View Original Abstract

Fast compression experiments performed using dynamic diamond anvil cells (dDACs) employing piezoactuators offer the opportunity to study compression-rate dependent phenomena. In this paper, we describe an experimental setup which allows us to perform time-resolved x-ray diffraction during the fast compression of materials using improved dDACs. The combination of the high flux available using a 25.6 keV x-ray beam focused with a linear array of compound refractive lenses and the two fast GaAs LAMBDA detectors available at the Extreme Conditions Beamline (P02.2) at PETRA III enables the collection of x-ray diffraction patterns at an effective repetition rate of up to 4 kHz. Compression rates of up to 160 TPa/s have been achieved during the compression of gold in a 2.5 ms fast compression using improved dDAC configurations with more powerful piezoactuators. The application of this setup to low-Z compounds at lower compression rates is described, and the high temporal resolution of the setup is demonstrated. The possibility of applying finely tuned pressure profiles opens opportunities for future research, such as using oscillations of the piezoactuator to mimic propagation of seismic waves in the Earth.