Skip to content

Ultra-long coherence times amongst room-temperature solid-state spins

MetadataDetails
Publication Date2019-08-28
JournalNature Communications
AuthorsErnst David Herbschleb, Hiromitsu Kato, Yukie Maruyama, Takuya Danjo, Toshiharu Makino
InstitutionsNational Institute of Advanced Industrial Science and Technology, Kyoto University Institute for Chemical Research
Citations313
AnalysisFull AI Review Included
  • Record-Breaking Coherence: Achieves the longest inhomogeneous spin-dephasing time T2 ≈ 1.54 ms* and Hahn-echo spin-coherence time T2 ≈ 2.43 ms for any solid-state electron spin at room temperature.
  • Novel Material Strategy: Uses phosphorus-doped (n-type) 12C-enriched single-crystal diamond (99.998% isotopic purity) to suppress paramagnetic vacancy complexes via Coulomb repulsion during CVD growth.
  • Optimal Doping Window: Identifies [P] = 6 × 1016 atoms cm-3 as the sweet spot balancing NV- state stabilization against phosphorus-induced magnetic noise (average T2 = 1.8 ms across 21 NV centers).
  • Best-in-Class Sensitivity: Delivers single-NV AC magnetic field sensitivity of η = 9.1 ± 0.3 nT Hz-1/2, improving prior best by nearly 2× through superior Rabi contrast and photon counts.
  • Decoherence Source Identification: Noise spectroscopy and single/double quantum T1 measurements pinpoint residual paramagnetic impurities (npara ≈ 3 × 1017 cm-3) as the limiting factor, with magnetic noise dominating over electric-field noise.
  • Quantum-Grade Diamond Advancement: Demonstrates that further T2 extension requires reducing paramagnetic defects and optimizing phosphorus concentration, opening a synthesis pathway for next-generation quantum devices.
ParameterValueUnitContext
T2* (inhomogeneous dephasing)1.54 (+1.91 / -0.50)msLongest recorded for solid-state electron spin at room temperature
T2 (Hahn-echo coherence)2.43 (+0.06 / -0.06)msLongest recorded for solid-state electron spin at room temperature
T2,dd (CPMG, 512 π-pulses)3.3msDynamical decoupling limit
T1SQ (longitudinal relaxation)7.4msSingle-quantum measurement
T1DQ3.4msDouble-quantum measurement
AC Magnetic Sensitivity (η)9.1 ± 0.3nT Hz-1/2Best single-NV room-temperature sensor
DC Magnetic Sensitivity~6nT Hz-1/2Derived from T2*
Optimal AC Frequency~833HzCorresponding τoptimum ≈ 1.2 ms
Phosphorus Concentration (optimal)6 × 1016atoms cm-3Sample C
Phosphorus Concentration Range3 × 1015 - 1 × 1017atoms cm-3Samples A-H
12C Enrichment99.998%Reduces nuclear spin bath
Residual 13C0.002%~0.002% natural abundance
Phosphorus Donor Level570meVActivation energy
Electron Mobility (300 K)~800cm2 V-1 s-1Hall-effect measurement
npara (paramagnetic impurities)~3 × 1017cm-3Extracted from noise spectrum
Coupling Strength (Δ)≥ 0.1MHzAverage NV-bath coupling
External Magnetic Field1.8mTApplied during experiments
Rabi Contrast37%High contrast enables better sensitivity
Ω (ms = 0 ↔ ±1 relaxation rate)~45s-1Magnetic noise contribution
γ (ms = -1 ↔ +1 relaxation rate)~1.2 × 102s-1Electric noise contribution
Growth Pressure150TorrMPCVD chamber
MW Power3600WMagnetron generator
SubstrateIb-type (111) diamond—Epitaxial growth template
  1. Epitaxial CVD Growth: Phosphorus-doped n-type diamond films grown on Ib-type (111)-oriented substrates via microwave plasma-enhanced CVD in a 5-kW magnetron reactor with load-lock system.
  2. Isotopic Enrichment: 12C-enriched methane (99.998%) purified by zirconium absorber to minimize 13C nuclear spin bath.
  3. Phosphorus Doping Control: PH3/H2 dilution ratio (1000 ppm) with PH3/CH4 varied from 12.5 to 2000 ppm to achieve target concentrations.
  4. Gas Chemistry: CH4/H2 ratio held constant at 0.4%; total gas flow 1000 sccm; base pressure < 2 × 10-8 Torr.
  5. Film Thickness: Tens of micrometres per epitaxial layer.
  6. Characterization: Secondary ion mass spectrometry (SIMS) for P incorporation; Hall-effect with Van-der-Pauw contacts for mobility/conductivity.
  7. NV Center Readout: Home-built confocal microscope with single-shot charge-state measurements; MW pulses via thin copper wire; magnetic field via near-sample coil.
  8. Pulse Sequences: Free-induction decay (FID), Hahn-echo, and Carr-Purcell-Meiboom-Gill (CPMG) dynamical decoupling for coherence time extraction.
  9. Noise Spectroscopy: Multi-pulse CPMG sequences to extract Lorentzian noise spectrum and identify decoherence sources.
  10. Sensitivity Measurement: AC magnetic field via synchronized sinusoidal field in Hahn-echo; 100,000 iterations for gradient calibration; 100 repetitions for σ1 uncertainty extraction.
  • Applicable Materials: This research demands Isotopically Enriched Optical-Grade Single-Crystal Diamond (SCD) with 12C > 99.99%, available through 6CCVD’s custom MPCVD growth services. Phosphorus doping at the critical 6 × 1016 atoms cm-3 level requires precise gas-flow control and PH3 handling expertise—6CCVD’s MPCVD platform is engineered for such ultra-light doping regimes.
  • Customization Potential: The paper specifies Ib-type (111)-oriented substrates and epitaxial layers with thicknesses “in the order of tens of micrometres.” 6CCVD can supply custom-oriented SCD substrates up to 10 mm thick and epitaxial SCD films from 0.1 µm to 500 µm, enabling exact replication of the layer architectures used here. For researchers building full quantum device stacks, 6CCVD offers in-house metallization (Ti/Pt/Au or other schemes) compatible with Van-der-Pauw Hall-effect contact configurations.
  • Surface Engineering for Shallow NVs: The paper references work on shallow NV engineering via sacrificial boron-doped p-type layers. 6CCVD supplies Heavy Boron-Doped PCD (BDD) for such sacrificial layers, with precise thickness control and post-growth etching compatibility.
  • Diamond Characterization Support: 6CCVD’s in-house PhD team can assist with material selection—matching phosphorus donor concentration, 12C enrichment level, and crystal orientation—to specific quantum sensing or spintronics project requirements.
  • Wafer-Scale & Custom Geometries: For groups scaling up NV-center arrays or diamond quantum device production, 6CCVD offers plates and wafers up to 125 mm (PCD) with laser-cutting services for custom chip dimensions.
  • Polishing for Optical Readout: The Rabi contrast and photon count improvements cited here depend critically on surface quality. 6CCVD delivers SCD with Ra < 1 nm polish, maximizing NV fluorescence yield and reducing optical decoherence pathways.

Call to Action: For custom specifications, phosphorus-doping consultation, or material selection for quantum-grade diamond projects, visit 6ccvd.com or contact our engineering team directly.

View Original Abstract

Abstract Solid-state single spins are promising resources for quantum sensing, quantum-information processing and quantum networks, because they are compatible with scalable quantum-device engineering. However, the extension of their coherence times proves challenging. Although enrichment of the spin-zero 12 C and 28 Si isotopes drastically reduces spin-bath decoherence in diamond and silicon, the solid-state environment provides deleterious interactions between the electron spin and the remaining spins of its surrounding. Here we demonstrate, contrary to widespread belief, that an impurity-doped (phosphorus) n-type single-crystal diamond realises remarkably long spin-coherence times. Single electron spins show the longest inhomogeneous spin-dephasing time ( $$T_2^ \ast \approx 1.5$$ T 2 * ≈ 1.5 ms) and Hahn-echo spin-coherence time ( T 2 ≈ 2.4 ms) ever observed in room-temperature solid-state systems, leading to the best sensitivities. The extension of coherence times in diamond semiconductor may allow for new applications in quantum technology.