Fabrication and performance of single crystal diamond neutron and gamma ray detectors

MetadataDetails
Publication Date2019-09-01
JournalAIP Advances
AuthorsJiawei Liu, Jiafeng Chang, Guoqiang Zhong, Jizong Zhang, Xiankai Pang
InstitutionsWuhan University, Taiyuan Normal University
Citations6
AnalysisFull AI Review Included
  • Detector platform: Two MPCVD single-crystal diamond detectors were fabricated and evaluated as combined neutron/gamma sensors. One incorporated a 5 µm 6LiF conversion layer; the second served as an uncoated comparison device.
  • Radiation sources: Device response was tested using 241Am-Be and 252Cf neutron sources and a 152Eu gamma source.
  • Neutron response: A clear neutron-signal peak was observed only for the detector coated with 95%-enriched 6LiF, demonstrating effective conversion of neutrons into charged reaction products.
  • Gamma response: Both SCD detectors responded to low-energy gamma radiation. Pulse-height spectra, count rate, and peak position varied with the incident gamma spectrum and lead shielding configuration.
  • Material advantages: Diamond’s 5.5 eV band gap, radiation hardness, low room-temperature leakage, and high carrier mobility support compact, fast, and robust radiation detection.
  • Recommended implementation: High-purity optical/electronic-grade SCD is preferred, with low defect density, controlled thickness, and stable metallization to minimize leakage and polarization while preserving charge-collection efficiency.
ParameterValueUnitContext
Diamond materialSingle-crystal CVD diamond—Active radiation-sensing material
Diamond band gap5.5eVBasis for low intrinsic leakage and radiation tolerance
Electron mobility relative to siliconApproximately 2×—Supports fast charge collection
Hole mobility relative to siliconApproximately 5×—Supports rapid detector response
Diamond breakdown field107V/cmEnables high-field operation
6LiF conversion-layer thickness5µmDeposited on one detector for neutron conversion
6Li enrichment95%Enriched converter layer
Neutron conversion reaction6Li(n,α)3H—Produces charged particles detectable in SCD
Detector architectures2—One 6LiF-coated and one uncoated SCD detector
Neutron sources241Am-Be; 252Cf—Used to evaluate neutron response
Gamma source152Eu—Used to verify gamma sensitivity
Raman diamond peakApproximately 1332cm−1Characteristic first-order diamond Raman line
Reported Raman FWHM5.1cm−1Indicates relatively high crystalline quality
Typical diamond crystal orientation(100) and (111) reflections—XRD pattern of the SCD material
Lead shielding tested1 and 3mmAltered gamma pulse-height response
Neutron moderator/attenuatorPolyethylene—Included in the radiation-test arrangement
Signal-processing chainPre-amplifier, shaping amplifier, oscilloscope, multichannel analyzer—Used for pulse-height and count-rate characterization
Detector biasSwept through negative and positive field rangesV/µmDark-current and electrical characterization
Characteristic dark-current scale shownApproximately −35 to 40nAExtracted from the reported current-field plot
Recommended SCD thickness range0.1-500µmAvailable from 6CCVD for custom detector work
Recommended PCD thickness range0.1-500µmAvailable from 6CCVD for larger-area or ruggedized designs
Substrate thicknessUp to 10mmAvailable for support and packaging configurations
Maximum stated PCD plate/wafer dimension125mmRelevant to scaled detector arrays or neutron/gamma instrumentation
  1. Material selection

    • Used high-quality CVD SCD as the active detection medium.
    • Characterized the crystal by Raman spectroscopy and X-ray diffraction.
    • Raman analysis showed the characteristic diamond feature near 1332 cm−1 with a reported FWHM of 5.1 cm−1.
  2. Detector fabrication

    • Fabricated two SCD radiation-detector structures.
    • Deposited a 5 µm 6LiF layer, enriched to 95% in 6Li, onto one detector.
    • Left the second detector uncoated to provide a comparison for neutron-conversion response and gamma sensitivity.
  3. Electrical integration

    • Mounted the diamond devices on printed circuit boards using epoxy resin and copper shielding structures.
    • Included pad connections and a detector bias supply.
    • Evaluated current as a function of applied electric field to assess leakage and electrical stability.
  4. Radiation-test configuration

    • Exposed the devices to 241Am-Be and 252Cf neutron sources.
    • Exposed the devices to a 152Eu gamma source.
    • Used polyethylene and lead plates to modify neutron and gamma fields.
    • Tested lead shielding at approximately 1 mm and 3 mm thicknesses.
  5. Signal acquisition

    • Connected each detector to a pre-amplifier and shaping amplifier.
    • Acquired pulse-height spectra and count-rate data using a multichannel analyzer and oscilloscope.
    • Compared coated and uncoated devices to distinguish neutron-conversion signals from direct gamma response.
  6. Performance interpretation

    • Identified a distinct neutron peak associated with the 6LiF-coated detector.
    • Evaluated gamma response through changes in count rate, spectral peak position, and pulse-height distribution.
    • Noted that the detector response was dependent on the incident gamma spectrum and shielding arrangement.
6CCVD materialRecommended useRationale
Optical Grade SCDPrimary detector platform for neutron/gamma sensor developmentLow defect density and high crystalline quality support stable charge transport, low dark current, and reproducible pulse-height spectra
Electronic-Grade SCDHigh-field detector structures requiring controlled electrical behaviorSuitable for optimizing charge collection and minimizing polarization
Standard SCDPrototype and research applications with cost or delivery constraintsAvailable in custom thicknesses and dimensions for detector development
Polycrystalline CVD diamondLarger-area or mechanically robust detector assembliesUseful when area, structural strength, or array-scale fabrication is more important than single-crystal spectral performance
Boron-Doped DiamondSpecialized electrode or conductive-diamond integration studiesRelevant where a conductive diamond layer is required for tailored electrical field management

For replication or extension of the reported work, optical-grade SCD is the preferred starting material. The paper’s key performance requirements—low leakage, clear pulse-height peaks, stable charge collection, and discrimination between coated and uncoated structures—depend strongly on crystal quality, thickness uniformity, surface preparation, and electrode quality.

  • Thickness control: 6CCVD can provide SCD from 0.1 µm to 500 µm, allowing optimization of:
    • neutron-conversion product range;
    • gamma absorption and sensitivity;
    • charge-collection distance;
    • operating voltage;
    • timing response and spectral resolution.
  • Detector geometry: Custom plate and wafer dimensions are available up to 125 mm for PCD. SCD dimensions can be specified according to the device layout, active area, and packaging requirements.
  • Surface quality: 6CCVD offers polishing capabilities of Ra < 1 nm for SCD and Ra < 5 nm for inch-size PCD, supporting reliable electrode formation and reduced surface-induced leakage.
  • Metallization: Internal metallization options include Au, Pt, Pd, Ti, W, and Cu. These materials support:
    • ohmic or Schottky electrode development;
    • multilayer contact stacks such as Ti/Pt/Au;
    • reduced contact resistance;
    • improved adhesion and wire-bonding compatibility;
    • high-field and low-leakage electrode designs.
  • Conversion layers: The paper specifically requires a 5 µm 6LiF layer enriched to 95% 6Li. 6CCVD can support the diamond component, dimensional definition, polishing, and compatible metallization; converter-layer deposition can be developed according to the target neutron reaction and packaging design.
  • Laser processing: Custom laser cutting and dimensional shaping can be used to define detector edges, electrode patterns, alignment features, and array geometries.
  • Substrates and packaging: Diamond substrates up to 10 mm thick are available for support, handling, and integration into detector assemblies.
  • 6CCVD’s in-house PhD team can assist with material selection for neutron/gamma detector projects, including:
    • SCD versus PCD selection;
    • crystal orientation and defect considerations;
    • thickness and active-area optimization;
    • electrode stack design;
    • leakage-current and polarization mitigation;
    • 6LiF converter-layer integration;
    • gamma-spectrum and neutron-reaction response planning.
  • The paper identifies contact fabrication as an area for further improvement. 6CCVD can address this through controlled surface polishing, metallization selection, adhesion-layer engineering, and customized electrode geometry.
  • For extension of the study, 6CCVD can support comparative devices such as:
    • coated versus uncoated SCD;
    • SCD versus PCD;
    • different SCD thicknesses;
    • alternative electrode metals;
    • varied active areas and bias fields;
    • detector arrays and multi-channel assemblies.
Detector componentRecommended specificationDevelopment objective
Active diamondOptical-grade SCD, 50-300 µm thickness range for initial evaluationBalance charge collection, gamma interaction, and manageable bias voltage
Crystal finishPolished to Ra < 1 nmReduce surface roughness and support low-leakage contacts
Electrode materialTi/Pt/Au or Ti/W/Au stack, depending on contact and packaging requirementsImprove adhesion, conductivity, wire bonding, and environmental stability
Neutron converterApproximately 5 µm 6LiF, 95% 6Li enrichmentReproduce the neutron-to-charged-particle conversion architecture
Detector sizeCustom SCD dimensions selected for the active area and fixtureOptimize count rate, field uniformity, and packaging
Optional comparison deviceUncoated SCD processed in the same geometrySeparate direct gamma response from converter-induced neutron signals
PCD alternative0.1-500 µm PCD, up to 125 mm plate sizeProvide a larger-area, mechanically robust platform where spectral resolution is less critical
ShippingGlobal DDU shipping; DDP availableSupport international research and instrument-development programs

Application-Specific Development Priorities

Section titled “Application-Specific Development Priorities”
  1. Reproduce the paper’s coated/uncoated architecture using matched SCD devices to isolate the contribution of the 6LiF converter.
  2. Optimize the SCD thickness for the intended radiation field:
    • thinner devices for faster response and lower bias;
    • thicker devices for greater interaction probability and charge generation.
  3. Control the electrode interface to reduce polarization and contact-induced spectral drift.
  4. Evaluate gamma response under controlled shielding using standardized source geometries and repeated measurements.
  5. Extend toward detector arrays where PCD plates up to 125 mm can support larger collection areas, while SCD elements can provide superior charge-transport uniformity.

For custom specifications or material consultation, visit 6ccvd.com or contact our engineering team directly.

View Original Abstract

Two high performance single crystal diamond (SCD) radiation detectors for neutrons and gamma ray have been fabricated. One was coated with a 5 μm 6LiF (95% enriched in 6Li) layer in order to detect the neutrons and the other one is without any conversion layer for comparison. The detectors are irradiated with the 241Am-Be and 252Cf neutron sources and 152Eu gamma source to test their performance. Under neutron sources, the neutron signal peak was clearly observed in the detector with the 6LiF conversion layer. Meanwhile, both detectors are responsive to the gamma rays at the low energy. The 152Eu gamma source was specially used to verify the gamma ray detection ability of the fabricated SCD detectors. The results show that the detector’s count rate and the gamma peak center position in the PHS depend on the incident gamma spectra critically. Combined, these results demonstrate that the design and fabrication process of the detectors are feasible.

  1. 2015 - Time response of 50 μm thickness single crystal diamond detectors [Crossref]
  2. 2001 - Properties, Growth and Applications of Diamond
  3. 1990 - Handbook of Semiconductor Silicon Technology
  4. 2016 - Impact of impurities and crystal defects on the performance of CVD diamond detectors [Crossref]
  5. 1999 - Proton irradiation of CVD diamond detectors for high-luminosity experiments at the LHC [Crossref]
  6. 2002 - High carrier mobility in single-crystal plasma-deposited diamond [Crossref]
  7. 2017 - Properties comparison between nanosecond X-ray detectors of polycrystalline and single-crystal diamond [Crossref]
  8. 1995 - Time response of a type IIa natural diamond photoconductor to long-pulse low-intensity soft x rays [Crossref]
  9. 1995 - Diamond photoconducting detectors as high power z-pinch diagnostics [Crossref]
  10. 1993 - Enhancement of photosensitivity by ultraviolet irradiation and photoconductivity spectra of diamond thin films [Crossref]