Skip to content

Optical Characterization of Nitrogen-Vacancy Centers Created by Proton Implantation in Diamond

MetadataDetails
Publication Date2020-01-01
JournalActa Physica Polonica A
AuthorsMateusz Schabikowski, Adam M. Wojciechowski, Marzena Mitura‐Nowak, Mariusz Mrózek, Andrzej Kruk
InstitutionsInstitute of Physics, Uniwersytet Komisji Edukacji Narodowej w Krakowie
Citations3
AnalysisFull AI Review Included

Optical Characterization of Nitrogen-Vacancy Centers Created by Proton Implantation in Diamond

Section titled “Optical Characterization of Nitrogen-Vacancy Centers Created by Proton Implantation in Diamond”
  • Core Achievement: Successful creation of Nitrogen-Vacancy (NV) centers in a 20 µm-deep layer of type-Ib diamond via 1.8 MeV proton beam implantation.
  • Dose Optimization: Analyzed NV creation efficiency and spin decoherence across a wide fluence range (1013 to 1016 ions/cm2) to determine optimum sensing parameters.
  • Defect Engineering: Used Focused Ion Beam (FIB) raster-scanning to produce precise 160 µm × 160 µm square sensor arrays with controlled exposure per pixel.
  • Activation Process: Post-implantation vacuum annealing at 850 °C for 2 hours facilitated vacancy migration and association with residual substitutional nitrogen.
  • Targeted Applications: Engineered thin sensor layers specifically designed for 2D magnetic field imaging, magnetometry, and bio-magnetic imaging.
  • Characterization Suite: Validated defects using Raman spectroscopy, fluorescence mapping, and Optically Detected Magnetic Resonance (ODMR).
ParameterValueUnitContext
Substrate MaterialType-Ib HPHT Diamond-Commercial Element Six single crystal
Substrate Dimensions3.0 × 3.0 × 0.3mm3(100)-oriented main surface
Initial Nitrogen Conc. [Ni]< 100ppmSubstitutional nitrogen content
Proton Energy1.8MeVVan de Graaff accelerator
Penetration Depth~20µmSRIM simulation result
Vacancies per Proton~7v/ionCalculated defect density
Implantation Doses1013 - 1016ions/cm2Fluence range tested
Beam Spot Size~20µmFocused ion beam diameter
Implanted Area160 × 160µm2Raster-scanned squares
Annealing Temperature850°CVacuum furnace
Annealing Duration2hVacancy migration phase
ODMW Frequency Range2820 - 2970MHzSpin resonance scan
Raman Shift Range500 - 4500cm-1Spectral characterization
  • Substrate Selection: Utilized commercially sourced type-Ib HPHT (100) diamond with < 100 ppm initial nitrogen concentration to maximize NV formation yield.
  • Surface Preparation: Implanted on the polished (100) face to minimize scattering losses during subsequent optical interrogation.
  • Ion Beam Delivery: Deployed 1.8 MeV protons from a Van de Graaff accelerator with a ~20 µm beam spot.
  • Spatial Structuring: Raster-scanned the beam across 160 µm × 160 µm areas, modulating exposure time per pixel to define sensor arrays.
  • Defect Activation: Annealed samples in vacuum at 850 °C for 2 hours to drive vacancy migration and NV center formation.
  • Optical Verification: Performed Raman spectroscopy (500 - 4500 cm-1) and photoluminescence mapping to confirm NV signature.
  • Spin Characterization: Applied Optically Detected Magnetic Resonance (ODMR) across 2770 - 2970 MHz to validate spin coherence.
  • Dose-Response Mapping: Correlated ODMR contrast and spin decoherence (T2) against implantation fluence to identify the optimal defect density regime.
  • Applicable Materials:

    • Optical Grade Single Crystal Diamond (SCD): 6CCVD’s high-purity SCD wafers are ideally suited as precursors for NV sensing applications. We offer tailored nitrogen doping profiles to provide the exact [Ni] specification required for NV ensemble yield optimization.
    • Custom (100)-Oriented Substrates: Our SCD plates can be supplied with precise crystallographic orientation and surface roughness (Ra < 1nm), ensuring compatibility with ion implantation beam alignment.
  • Customization Potential:

    • Geometry: 6CCVD fabricates SCD and PCD plates up to 125mm, allowing researchers to scale beyond the 3.0 mm × 3.0 mm sample format used in this study for larger imaging arrays.
    • Thickness Control: Substrate thicknesses up to 10mm are available, ideal for integrating thin (20 µm) sensing layers within robust bulk platforms.
    • Internal Metalization: For sensing devices requiring microwave delivery structures or coplanar waveguides (essential for ODMR excitation), we offer in-house deposition of Ti, Pt, Au, W, and Pd. This eliminates the need for third-party fabrication steps.
    • Laser Cutting: We provide precision laser cutting services to define custom sensor array footprints, including the 160 µm × 160 µm geometries demonstrated in this paper.
  • Engineering Support:

    • The 6CCVD in-house PhD team can provide material consultation regarding the trade-off between nitrogen concentration, vacancy density, and spin decoherence time (T2). For magnetometry and bio-magnetic imaging projects, we assist in selecting the optimal starting substrate specifications to maximize NV creation efficiency in the sub-20 µm surface layer.
  • Call to Action: For custom specifications, substrate consultation, or metallization integration on diamond for quantum sensing applications, visit 6ccvd.com or contact our engineering team directly.

View Original Abstract

We report the results of high-energy (1.8 MeV) proton implantation in a type-Ib diamond.The focused ion beam was used to introduce vacancies in a 20 µm-deep layer with applied doses in the range of 10 13 to 10 16 ions/cm 2 .The sample was subsequently annealed in vacuum which resulted in migration of vacancies and their association with the nitrogen present in the diamond matrix.We studied properties of the formed nitrogen-vacancy centers with photoluminescence and optically detected magnetic resonance.The samples are aimed to be used in sensing applications, e.g., magnetometry and bio-magnetic imaging.