Skip to content

Fabrication of electrolyte-gate nanocrystalline diamond- based field effect transistor (NCD-EGFET) for HIV-1 Tat protein detection

MetadataDetails
Publication Date2020-02-01
JournalIOP Conference Series Materials Science and Engineering
AuthorsNurul Atiqah Ahmad, A. Rahim Ruslinda, Nur Syakimah Ismail, Bohuslav Rezek
InstitutionsCzech Academy of Sciences, Institute of Physics, Universiti Malaysia Perlis
Citations1
AnalysisFull AI Review Included
  • Device Fabricated: Electrolyte-Gate Field Effect Transistor (EGFET) utilizing nanocrystalline diamond (NCD) as the transducing material on a silicon substrate for biosensing applications.
  • Target Application: Label-free detection of HIV-1 Tat protein via RNA aptamer functionalization.
  • Transducer Material Advantage: NCD offers biocompatibility, surface wettability, high stability, and surface conductivity post-hydrogenation.
  • Detection Performance: Demonstrated a highly reproducible gate potential shift of ~174 mV upon binding of 100 pM HIV-1 Tat protein.
  • Fabrication Method: Microwave ellipsoidal cavity CVD reactor followed by standard photolithographic patterning (mark, channel, contact, and cover alignment).
  • Channel Geometry: Active gate channels defined with 60 µm length and 20 µm width, terminated with hydrogen bonding for surface conductivity.
  • Significance: Validates NCD as a robust, biocompatible semiconductor platform for next-generation electrochemical biosensors operating in wet/physiological conditions.
ParameterValueUnitContext
Substrate MaterialSilicon (Si/SiO2)—10 mm × 10 mm × 1 mm oxidized wafer
Active TransducerNanocrystalline Diamond (NCD)—Grown via MPCVD
Diamond Film Thickness~450nmDeposition duration 4.5 h
Diamond Grain Size~250nmDetermined via SEM analysis
Nucleation Particle Size4.8 ± 0.6nmBuckydiamond in NanoAmando solution
Nucleation Layer Thickness5-25nmUltrasonic seeding layer
CH4 Concentration in H21%Gas mixture ratio
Deposition Pressure30mbarProcess chamber vacuum
Microwave Power1000WEllipsoidal cavity reactor
Deposition Temperature550-600°CSubstrate temperature
Hydrogenation Temperature600°CSurface conductivity activation
Hydrogenation Duration10minH2 plasma treatment
Gate Channel Length60µmPhotolithographic patterning
Gate Channel Width20µmPhotolithographic patterning
Contact Adhesion LayerTitanium (Ti)10 nmE-beam/sputter deposition
Contact Conductive LayerGold (Au)50 nmBiocompatible electrode
Reference ElectrodeAg/AgCl—Gate terminal in electrolyte
Electrolyte1 mM PBSpH 7.4Physiological measurement buffer
Target AnalyteHIV-1 Tat Protein100 pMSpecific binding partner
Recognition ProbeRNA Aptamer—Functionalized on gate surface
Detection Signal (ΔVg)~174mVNegative shift upon binding
Isoelectric Point (Tat)9.88pIConfirms positive charge at pH 7.4
  1. Substrate Preparation: Oxidize 10 mm × 10 mm × 1 mm silicon substrates in an oxidation furnace to form a SiO2 barrier layer.
  2. Substrate Cleaning: Ultrasonicate in isopropyl alcohol (10 min), rinse with DI water.
  3. Nanopowder Nucleation: Ultrasonic bath for 30-40 min in a colloidal suspension (200 mL DIW + 5 mL NanoAmando 5.0 w/v% diamond nanopowder) to seed the growth surface.
  4. MPCVD Diamond Deposition: Grow NCD thin film in a microwave ellipsoidal cavity reactor for 4.5 hours.
    • Pressure: 30 mbar
    • Gas Mixture: 1% CH4 in H2
    • Microwave Power: 1000 W
    • Substrate Temperature: 550-600 °C
  5. Surface Conductivity Activation: Hydrogenate NCD film in H2 plasma at 600 °C for 10 min within the same MPCVD reactor.
  6. Photolithographic Mark Alignment: Spin-coat HDMS (1:4) at 3000 rpm for 10 sec; spin-coat positive photoresist (MA 15) at 3000 rpm for 30 sec; soft-bake at 100 °C for 2 min.
  7. UV Exposure & Development: Align under mask aligner, expose to UV for 6 sec, develop for 45 sec, and oxygen plasma clean for 1 min.
  8. Metal Contact Deposition: Deposit 10 nm Ti adhesion layer followed by 50 nm Au via physical vapor deposition.
  9. Lift-Off: Remove excess metal in acetone to define alignment marks.
  10. Channel & Contact Patterning: Repeat photolithography process to define the 60 µm × 20 µm active gate channel and source/drain contact pads.
  11. Final Passivation/Cover: Pattern a dielectric cover layer (e.g., SU-8 or polyimide) to isolate contact pads and expose only the active gate area to the electrolyte.
  12. Biofunctionalization: Immobilize RNA aptamer specific to HIV-1 Tat onto the hydrogen-terminated NCD active gate channel.
  13. Electrical Measurement: Measure Ids-Vgs transfer characteristics using a Keithley 2400 Source Meter and 6487 Picoammeter with an Ag/AgCl reference gate electrode.

The fabrication of high-sensitivity EGFET biosensors requires extremely uniform diamond films with precise control over surface termination, doping, and grain boundary morphology. Below is how 6CCVD’s capabilities align with the requirements of this research.

  • Nanocrystalline Diamond (NCD) Films: The paper utilized NCD grown via MPCVD with a 1% CH4/H2 recipe at 30 mbar and 1000 W. 6CCVD routinely manufactures custom NCD and Polycrystalline Diamond (PCD) wafers up to 125 mm diameter, capable of replicating and scaling this exact nanocrystalline morphology.
  • Surface-Terminated Diamond: The hydrogen-terminated surface (H-diamond) is critical for inducing p-type surface conductivity via electrolyte gating. 6CCVD provides hydrogenated diamond wafers with ultra-low surface roughness (Ra < 5 nm for inch-size PCD), ensuring uniform electrostatic potential across the 60 µm × 20 µm channel architecture.
  • Ultra-Thin Film Capability: The paper utilized a ~450 nm thick film. 6CCVD offers diamond thickness ranges from 0.1 µm to 500 µm, enabling researchers to optimize transducer capacitance and minimize charge screening effects for future device iterations.
  • Custom Metalization: The paper relies on a 10 nm Ti / 50 nm Au contact stack. 6CCVD offers in-house custom metalization using Au, Pt, Pd, Ti, W, and Cu. We can provide patterned metal contacts directly on your diamond substrates, eliminating the need for in-house lithography and PVD systems.
  • Laser Cutting & Dicing: While the paper used 10 mm × 10 mm Si chips, 6CCVD provides laser-cut custom geometries down to specific micron-level channels, enabling rapid prototyping of novel FET architectures.
  • Wafer-Scale Production: Scaling up from single 10 mm chips to full 100 mm or 125 mm wafers introduces challenges with film uniformity and defect density. 6CCVD’s MPCVD reactors are optimized for high-uniformity, wafer-scale diamond deposition required for multiplexed biosensor arrays.

Navigating the transition from a single-device laboratory demonstration (a single 174 mV response to HIV-1 Tat) to a clinically viable diagnostic requires deep materials expertise. 6CCVD’s in-house PhD engineering team specializes in MPCVD process optimization, surface chemistry, and carrier transport in diamond. We assist clients in selecting the optimal diamond grade—whether it be Optical Grade SCD for fundamental studies or specialized PCD for scalable electrochemical arrays—for projects spanning biosensing, quantum sensing, and power electronics. Our team can help you engineer the grain boundary density, sp2/sp3 ratio, and surface termination energy to maximize your device’s sensitivity and limit of detection.

For custom specifications, wafer-scale material consultation, or to request a quote on patterned diamond wafers, visit 6ccvd.com or contact our engineering team directly.

View Original Abstract

Abstract In this paper, we reported on the fabrication process of electrolyte-gate field effect transistor using nanocrystalline diamond as a sensing transducer. The fabrication procedure was begin with the growth of nanocrystalline diamond thin film on silicon/silicon dioxide (Si/SiO 2 ) substrate using microwave plasma-enhanced chemical vapour deposition (CVD). Then the photolithography process was performed in order to design and pattern the field effect transistor device with the active gate channel of 60 µm length and 20 µm width. Each device consists of three active gate channel which connecting to three different pairs of source and drain contact. The surface morphology of fabricated NCD-EGFET was characterized using Scanning Electron Microscope to clarify the active gate channel of the device and the grain size of nanocrystaline diamond. The current-voltage ( I-V ) measurement of the device were carried out to study the electrical behaviour for HIV-1 Tat protein detection via RNA aptamer as sensing probe.