Skip to content

Definition of the NV-center orientations relative to the diamond crystal plane

MetadataDetails
Publication Date2020-11-01
JournalJournal of Physics Conference Series
AuthorsН. С. Кукин, Н. И. Каргин, I O Korchevaya, Anna R. Muradova, P. A. Semenov
InstitutionsNational Research Nuclear University MEPhI, Institute of Engineering Physics
Citations1
AnalysisFull AI Review Included
  • Core Objective: Determine the crystallographic orientations of all four Nitrogen-Vacancy (NV) center axes in a CVD-grown diamond by monitoring ODMR resonance shifting under an in-plane rotating magnetic field.
  • Material Platform: Bulk single-crystal diamond (SCD) produced by the CVD method with a nitrogen concentration of ~1 ppm, enabling a dense ensemble of NV color centers.
  • Measurement Technique: Optically Detected Magnetic Resonance (ODMR) tracking mS = ±1 ground-state spin transitions at room temperature using continuous-wave microwave excitation.
  • Key Experimental Parameters: External static magnetic field B = 35 G rotated within the (001) crystal plane over almost 360°; microwave frequency swept around 2.87 GHz perpendicular to the crystal plane.
  • Key Outcome: Experimental angular dependences of the ODMR dips match simulated curves, providing a robust method to map the four NV axes to crystal plane geometry.
  • Strategic Value: Establishes a reliable, room-temperature alignment protocol for ensemble NV magnetometry, gradiometry, and quantum sensing device manufacturing.
  • Underlying Platform Validity: Confirms CVD diamond with controlled nitrogen doping as a viable, scalable host for spin-based quantum technology components.
ParameterValueUnitContext
Diamond Growth MethodCVD—Single-crystal bulk substrate
Nitrogen Concentration~1ppmNV center precursor density
Operating Temperature300 (Room temp)KAll ODMR measurements
Static Magnetic Field (B)35G (Gauss)Rotated within crystal plane
B-field Rotation Range~360degreesAround the sample normal axis
Microwave Frequency (center)~2.87GHzElectron spin resonance (mS=0 ↔ ±1)
Microwave PolarizationPerpendicular to crystal plane—Microwave B1 geometry
Detection MethodODMR (photoluminescence)—Spin-dependent fluorescence readout
NV SymmetryC3v—Defines four possible orientations in diamond lattice
Number of NV Orientations4—One per {111} crystallographic family
Sample TypeBulk SCD—Ensemble (not single NV) measurement
Surface ConstraintIn-plane rotation vector—Targeted (001) plane orientation
  1. Material Selection: Use CVD-grown single-crystal diamond with ~1 ppm nitrogen to guarantee a high density of NV centers suitable for ensemble ODMR.
  2. Sample Preparation: Mechanically and chemically polish a bulk diamond plate to obtain well-defined planar faces (the (001) face assumed).
  3. Magnetic Field Setup: Position the sample in a static external field of 35 G so that B lies entirely in the diamond crystal plane.
  4. Field Rotation Protocol: Mechanically rotate the sample (or the magnet) around the surface normal to sweep B from 0° to 360° relative to the crystal axis.
  5. Microwave Excitation: Apply continuous-wave microwave radiation at ~2.87 GHz with the B1 vector perpendicular to the crystal plane to drive allowed mS = 0 ↔ ±1 transitions.
  6. Optical Readout: Illuminate the diamond with green laser (standard for NV excitation) and monitor red photoluminescence; dips in PL indicate resonance.
  7. Angular Sweep: Record ODMR spectra at each rotation angle, extracting resonance frequencies for all four NV orientations.
  8. Simulation Comparison: Fit experimental angular curves against simulated Zeeman-split resonance frequencies based on the four {111} axis geometry and C3v symmetry.
  9. Axis Mapping: Assign the four observed angular dependences to the four physical NV orientations relative to the crystal plane.

This work demonstrates a precision magnetometry workflow that relies entirely on the quality of the underlying diamond host. The following 6CCVD offerings align directly with the requirements of this research:

Paper Requirement6CCVD Capability
CVD-grown bulk SCD with controlled NOptical Grade SCD grown via MPCVD with optional low-N specifications
Well-defined crystallographic planeLaser-cut SCD plates with orientation accuracy, custom dimensions up to 125 mm
Smooth optical-grade surface for PL collectionSCD polishing to Ra < 1 nm
Defined nitrogen/VV ensemble densityTunable nitrogen incorporation for ensemble NV densities
Stable host for room-temperature ODMRSingle Crystal Diamond substrates up to 10 mm thick

Applicable Materials:

  • Optical Grade SCD (single crystal diamond): Optimal for room-temperature ODMR ensemble magnetometry. 6CCVD’s MPCVD-grown single crystals provide the low background impurity, well-defined {100}/{111} planes, and superior surface polish required to resolve all four NV axis resonances as demonstrated in this paper.
  • Engineered Grade SCD (custom N levels): For clients who need to tune the NV center density away from the default ~1 ppm benchmark used here, 6CCVD offers engineered nitrogen incorporation during the CVD growth phase.

Customization Potential:

  • The authors rotated a 35 G field through nearly 360°, indicating the sample plane was critical. 6CCVD provides laser cutting and orientation service so crystals can be delivered already aligned to a specified crystal plane (e.g., (001)), eliminating downstream orientation work.
  • Optional custom metallization (Ti / Pt / Au / W) can be pre-deposited in-house to facilitate integration with coplanar microwave waveguides or stripline resonators required for ODMR setups, reducing fabrication burden on the research team.
  • Thickness control from 0.1 µm to 500 µm (SCD) allows matching of substrate absorption and optical path length for both transmission and reflection-mode ODMR geometries.

Engineering Support:

  • 6CCVD’s in-house PhD technical team can assist with material selection for ensemble NV magnetometry, gradiometers, and quantum sensing demonstrators, including guidance on N concentration, sample geometry, and surface preparation to maximize ODMR contrast.
  • For groups scaling ODMR from single-NV proof-of-concept to arrayed or wafer-scale devices, 6CCVD can advise on homogeneity across substrates up to 125 mm.

Call to Action: For custom specifications or material consultation, visit 6ccvd.com or contact our engineering team directly.

View Original Abstract

Abstract We investigate the electron spin resonance of an ensemble of Nitrogen-Vacancy color centers in a bulk diamond crystal obtained by CVD-method. The diamond crystal had 1 ppm concentration of nitrogen. The four possible orientations of the NV-center in the crystal lattice lead to different dependences of a magnitude and an orientation of the external static magnetic field. We used the field of 35 Gauss with the vector in the plane of the crystal. We could rotate it to a certain angle within almost 360 degrees around the normal vector to the plane of the crystal. The goal was to define the unknown orientations of the four axes of the NV-centers relatively to the crystal plane. Experimental results obtained at room temperature with a continuous microwave excitation and presented in this paper are in a good agreement with our simulations.

  1. 2005 - Generation of single color centers by focused nitrogen implantation [Crossref]
  2. 2011 - Properties of nitrogen-vacancy centers in diamond: group theoretic approach [Crossref]
  3. 2012 - Enhanced metrology using preferential orientation of nitrogen-vacancy centers in diamond
  4. 2014 - Measuring the defect structure orientation of a single NV− centre in diamond [Crossref]
  5. 2009 - Excited-state spectroscopy of single NV defects in diamond using optically detected magnetic resonance
  6. 2016 - Experimental observation of optically detected magnetic resonance in the crystal diamond with nitrogen impurities
  7. 2017 - Rabi oscillations on diamond qubits by using a green laser