Skip to content

Measuring the Emission and Decay Time of a Cathode Plasma

MetadataDetails
Publication Date2023-05-21
AuthorsM. R. Howard, J. E. Coleman, S. Lidia
InstitutionsMichigan United, Michigan State University

A cathode test stand has been designed to study cathode emission characteristics over pulse lengths of up to 2.5μs. A suite of diagnostics is used to characterize both the initial turn-on of emission and excess emission. One diagnostic amongst the suite is used to monitor the emission directly by imaging the cathode face with an ICCD. We measure the lifetime of the hydrogen plasma through time resolved measurements with the ICCD. We have found that the time constant for the cathode decay ranges from 0.5μs to 1μs, In some cases, the emission current rapidly exceeds what is expected due to ChildLangmuir. We also monitor excess emission in the diode with diamond detectors and capacitive pickups. Example measurements will be presented.