| Metadata | Details |
|---|
| Publication Date | 2023-09-10 |
| Journal | Advanced Sensor Research |
| Authors | Madhav Gupta, Tongtong Zhang, Lambert Yeung, Jiahua Zhang, Yayin Tan |
| Institutions | Sichuan University, Dongguan University of Technology |
| Citations | 4 |
| Analysis | Full AI Review Included |
- Dual-defect quantum thermometry: First-ever demonstration of simultaneous, cross-validated temperature sensing in a single bulk diamond co-doped with Nitrogen-Vacancy (NV) and Silicon-Vacancy (SiV) centers.
- Complementary modalities: NV centers enable high-sensitivity spin-based (ODMR) readout (22 mK·√Hz-1), while SiV centers provide an artefact-immune all-optical (PL) readout (86 mK·√Hz-1) — both interrogated in the same sample.
- Cross-validation under artefacts: A perfect linear correlation between NV-ODMR frequency shift and SiV zero-phonon line (ZPL) shift permits real-time validation, even in the presence of dynamic magnetic fields (40 G).
- Biological relevance: SiV emission at 737 nm falls within the near-infrared biological transparency window, making the platform directly applicable to in-vivo and intracellular thermometry.
- Single-platform architecture: Unlike previous dual-mode approaches using physically separated nanodiamonds and UCNPs, both defects are embedded in one bulk host — preserving spatial and temporal co-localization.
- Proof-of-concept milestone: Establishes a new reliability standard for quantum thermometry in complex electromagnetic environments (e.g., neuron cells, integrated electronics).
| Parameter | Value | Unit | Context |
|---|
| NV-ODMR temperature sensitivity | 22 | mK·√Hz-1 | Spin-based readout |
| SiV-PL temperature sensitivity | 86 | mK·√Hz-1 | All-optical readout |
| NV Zero-Field Splitting (D) | ≈2.87 | GHz | Room temperature baseline |
| NV-ODMR frequency shift (dD/dT) | -73.79 | kHz/°C | Linear fit |
| SiV ZPL position (25 °C) | 737 | nm | 1.68 eV |
| SiV ZPL thermal shift (dλ/dT) | 0.0398 | nm/°C | Linear fit |
| SiV ZPL linewidth (FWHM) | ≈4.8 | nm | Room temp, ensemble |
| NV ZPL linewidth (FWHM) | ≈3 | nm | Room temp, ensemble |
| SiV ZPL FWHM thermal shift | 0.0084 | nm/°C | Broadening rate |
| SiV Debye-Waller Factor | ≈0.7 | — | Fraction of emission in ZPL |
| NV Debye-Waller Factor | 0.04 | — | Fraction of emission in ZPL |
| SiV ground-state spin-orbit splitting | ≈50 | GHz | Intrinsic |
| SiV spin quantum number | S = 1/2 | — | Electron spin |
| CW-ODMR linewidth | 12 | MHz | Ensemble measurement |
| ODMR contrast | 11.74 | % | 25 °C |
| Excitation wavelength | 532 | nm | PL and ODMR pump |
| Operating temperature range | 27-48 | °C | Tested window |
| Dynamic B-field amplitude | 40 | G | Artefact test condition |
| SiV photostability deviation | 0.41 | % | Over measurement duration |
| Cross-validation sensitivity (ZPL vs D) | -0.548 | nm/MHz | Dual-mode linkage |
| Cross-validation sensitivity (FWHM vs D) | -0.114 | nm/MHz | Dual-mode linkage |
- Sample platform: Bulk single-crystal diamond (1b-type) co-doped with nitrogen (for NV formation) and silicon (for SiV formation) via in-situ doping during CVD growth.
- Optical characterization: Custom-built wide-field quantum diamond microscope (see Supporting Information Fig. S1) used for both PL and CW-ODMR mapping.
- PL spectroscopy: 532 nm laser excitation; ZPL peaks identified at 637 nm (NV) and 737 nm (SiV); Lorentzian fitting extracts peak position and linewidth.
- ODMR readout: Continuous-wave ODMR at zero-field splitting around 2.87 GHz; resonance frequency tracked vs. temperature for thermometry.
- Temperature calibration: Sample stage swept between 27 °C and 48 °C; both modalities recorded simultaneously to establish linear cross-calibration.
- Artefact test: External dynamic magnetic field of 40 G applied to demonstrate immunity of SiV readout and need for NV cross-validation (and vice versa).
- Data correlation: NV-ODMR frequency, SiV ZPL position, and SiV FWHM fitted with linear regressions; cross-sensitivity coefficients extracted for real-time validation.
- Noise-floor extraction: Shot-noise-limited sensitivity derived from integration-time sweeps for both modalities.
| Research Requirement | Recommended 6CCVD Product |
|---|
| Co-doped bulk diamond with NV + SiV centers | Custom Co-Doped Single Crystal Diamond (SCD) — controlled N and Si incorporation during MPCVD growth |
| High optical-grade host for ZPL analysis | Optical Grade SCD — Ra < 1 nm polished surfaces minimize scattering at 637 nm and 737 nm |
| Large-area, low-birefringence host for wide-field microscopy | SCD Plates/Wafers up to 125 mm (PCD equivalent available; SCD sizes confirmed upon request) |
| Thickness tuning for transmission vs. confocal geometry | SCD Thickness Range 0.1 µm - 500 µm |
- Tailored co-doping profiles: 6CCVD MPCVD reactors allow precise control of N and Si precursor flows, enabling tunable NV and SiV ensemble densities for optimized signal-to-noise in quantum sensing.
- Custom metalization for device integration: Ti, Pt, Au, Pd, W, and Cu deposition available in-house — useful for integrating microwave striplines (for ODMR drive) or microheaters (for in-situ calibration) directly on the diamond.
- Laser cutting & dicing: Custom geometries (membranes, micro-discs, patterned arrays) supported for miniaturized sensor packages or fiber-coupled probes.
- Surface polishing: Sub-nanometer Ra finishes on SCD preserve ZPL spectral purity by reducing surface-related luminescence background.
- Substrate options: For hybrid integration with photonic or electronic chips, diamond substrates up to 10 mm thickness are available.
- PhD-led consultation: 6CCVD’s in-house materials science team can advise on defect engineering — including target NV/SiV concentration ratios, post-growth annealing recipes, and surface passivation strategies — to replicate or extend this dual-defect thermometry platform.
- Application-specific guidance: Whether the end use is intracellular nanothermometry, on-chip thermal mapping of microelectronics, or quantum-enhanced metrology, our engineers can recommend the optimal material grade and geometry.
- Rapid prototyping: Custom geometries and doping specifications can be quoted with short lead times for research-scale quantities.
Call to Action: For custom specifications or material consultation, visit 6ccvd.com or contact our engineering team directly.
View Original Abstract
Abstract The contactless temperature measurement at micro/nanoscale is vital to a broad range of fields in modern science and technology. The nitrogen‐vacancy (NV) center, a kind of diamond defect with unique spin‐dependent photoluminescence, is recognized as one of the most promising nanothermometers. However, this quantum thermometry technique is prone to a number of possible perturbations, which will unavoidably degrade its actual temperature sensitivity. Here, for the first time, a cross‐validated optical thermometry method is developed using a bulk diamond sample containing both NV centers and silicon‐vacancy (SiV) centers, achieving a sensitivity of 22 and 86 mK (√Hz) −1 respectively. Particularly, the latter has been intrinsically immune to those influencing perturbations for the NV‐based quantum thermometry, hence serving as a real‐time cross‐validation system. As a proof‐of‐concept demonstration, a trustworthy temperature measurement is shown under the influence of varying magnetic fields, which is a common artefact present in practical systems. This multi‐modality approach allows synchronized cross‐validation of the measured temperature, which is required for micro/nanoscale quantum thermometry in complicated environments such as a living cell.