Skip to content

A porous flower-like boron and nitrogen co-doped diamond film electrode for the enhanced detection of copper ions

MetadataDetails
Publication Date2026-01-01
JournalRSC Advances
AuthorsMeixuan Li, Mingchao Yang, Xiaoxi Yuan, C. Li, Feng Yang
InstitutionsHebei Normal University of Science and Technology, Jilin Engineering Normal University
AnalysisFull AI Review Included
  • Innovation: Bottom-up synthesis of a porous flower-like boron and nitrogen co-doped diamond (PFBND) film for electrochemical sensing, eliminating the need for masks or reactive ion etching.
  • Fabrication Method: Microwave plasma CVD (MPCVD) using CH4/H2/B(OCH3)3/N2 gas chemistry on P-type Si, followed by selective thermal annealing at 800 °C in air to remove non-diamond carbon (NDC).
  • Surface Architecture: Achieved vertically aligned, columnar diamond nanostructures (200-300 nm grain size) with a high specific surface area and nanoscale tip features that enhance local current density via a “tip current collection” effect.
  • Doping Strategy: Synergistic co-doping of boron (for conductivity and helical (100) growth) and nitrogen (for (100) faceting and secondary nucleation) enabled the unique flower-like morphology.
  • Sensor Performance: Demonstrated highly sensitive detection of Cu2+ via differential pulse anodic stripping voltammetry (DPASV), achieving a limit of detection (LOD) of 0.28 mg L-1 with a linear range of 1-100 mg L-1.
  • Electrochemical Stability: Exhibited a wide potential window, low background current, and excellent selectivity against common interfering ions, validated through practical recovery tests.
  • Simulation Support: COMSOL Multiphysics finite element modeling confirmed electric field concentration at PFBND tips, validating the structural advantage for enhanced electrochemical response.
ParameterValueUnitContext
Detection TargetCu2+ (Copper ions)—Heavy metal environmental sensor
TechniqueDifferential Pulse Anodic Stripping Voltammetry (DPASV)—Electrochemical measurement
Limit of Detection (LOD)0.28mg L-1Calculated as 3s/S
Linear Detection Range1-100mg L-1DPASV calibration response
Working Electrode Area0.10cm2Exposed PFBND film area
Deposition MethodMPCVD (Microwave Plasma CVD)—2.45 GHz system
SubstrateP-type Si (mirror-polished)—Nucleation-seeded
Nanodiamond Seed Size~5nmUltrasonic seeding for 60 min
Gas Flow Rates (CH4/H2/B/N2)20 / 200 / 2 / 1sccmPFBND/NDC composite growth
Growth Duration6hoursFilm deposition phase
Boron SourceB(OCH3)3 (trimethyl borate)—Liquid precursor, H2 carrier
Annealing Temperature800°CNDC removal via oxidation
Annealing Duration20minutesIn air ambient
Grain Size200-300nmColumnar diamond nanostructure
Raman Peak (Diamond)1332cm-1Confirmed sp3 phase post-annealing
Raman Peak (NDC)~1550cm-1Removed after annealing
Fano Effect Peaks500, 1200cm-1Heavy boron doping signature
Electrical Conductivity2 × 104S m-1Input for COMSOL simulation
Electrolyte0.1 M acetate buffer (pH 5.5)—CV and DPASV medium
Measurement Temperature30°CControlled ambient
Reference ElectrodeSaturated Calomel Electrode (SCE)—Three-electrode setup
Counter ElectrodePlatinum wire—Three-electrode setup
EIS Redox Probe5 mM [Fe(CN)6]3-/4- + 0.1 M KCl—Impedance characterization
Ultra-pure Water Resistivity18.2MΩ cmSolution preparation
XPS Analysis Range182-198, 282-288, 394-406, 528-538eVC 1s, B 1s, N 1s, O 1s regions
Laser Wavelength (Raman)532nmExcitation source
  1. Substrate Preparation: Mirror-polished P-type Si substrates immersed in an aqueous nanodiamond suspension (~5 nm powder) under ultrasonication for 60 minutes to seed nucleation sites.
  2. Substrate Cleaning: Sequential ultrasonication in acetone, ethanol, and deionized water for 10 minutes each, followed by N2 drying.
  3. MPCVD Deposition: Growth of the PFBND/NDC composite film using a 2.45 GHz microwave plasma CVD system with a gas mixture of CH4 (20 sccm), H2 (200 sccm), B(OCH3)3 (2 sccm, H2-carried), and N2 (1 sccm) for 6 hours.
  4. NDC Removal: Thermal annealing of the composite at 800 °C in air for 20 minutes to selectively oxidize and remove the non-diamond carbon phase, exposing the porous flower-like diamond morphology.
  5. Morphological Characterization: SEM imaging (JSM-6480LV) to confirm columnar grain structure and tip formation.
  6. Phase Analysis: Raman spectroscopy (532 nm laser, Renishaw inVia) to verify diamond sp3 phase and monitor NDC removal.
  7. Surface Chemistry: XPS (VG ESCALAB MK II) to analyze chemical bonding states of C, B, N, and O.
  8. Electrochemical Testing: CV and DPASV performed on a CHI 760E workstation in 0.1 M acetate buffer (pH 5.5) at 30 °C; EIS conducted in ferri/ferrocyanide redox probe.
  9. Simulation: COMSOL Multiphysics “Electric Currents” module used to model free-electron density and electric field distribution near PFBND tips.
  • Applicable Materials:

    • The PFBND film described in this study is a heavy boron-doped nanostructured polycrystalline diamond (PCD) with secondary nitrogen incorporation. 6CCVD’s Heavy Boron-Doped PCD and Optical Grade Nanostructured PCD are ideal substrates for replicating or extending this research, offering tunable boron concentrations (>1020 cm-3) and the ability to engineer columnar grain morphologies via proprietary MPCVD process optimization.
  • Customization Potential:

    • This research required precise gas-phase co-doping with B(OCH3)3 and N2 to achieve the flower-like morphology. 6CCVD offers fully customizable MPCVD recipes to tailor doping ratios, growth rates, and nanostructured surface features.
    • For electrode integration, 6CCVD provides in-house metalization services (Au, Pt, Pd, Ti, W, Cu) to facilitate ohmic contact formation on BDD working electrodes.
    • Laser cutting and shaping are available to define precise electrode geometries (e.g., 0.10 cm2 working area) from wafer-scale diamond films, eliminating the need for post-deposition dicing.
  • Engineering Support:

    • 6CCVD’s in-house PhD-level engineering team can collaborate on material selection, doping optimization, and surface morphology engineering for heavy metal ion electrochemical sensing platforms, including Cu2+, Pb2+, Cd2+, and Hg2+ detection.
    • We support clients in transitioning from proof-of-concept nanostructured electrodes to scalable, mask-free manufacturing, leveraging selective post-growth annealing strategies similar to those demonstrated in this paper.
  • Quality Assurance:

    • 6CCVD provides Raman spectroscopy, XPS, and SEM characterization with every custom order to verify sp3 phase purity, doping homogeneity, and surface morphology—ensuring batch-to-batch reproducibility for sensor fabrication.
  • Call to Action:

    • For custom specifications, tailored doping profiles, or material consultation on nanostructured diamond sensor development, visit 6ccvd.com or contact our engineering team directly.
View Original Abstract

was achieved. The sensor exhibited excellent selectivity for detecting copper ions against common interfering ions, ensuring reliable detection in complex environmental samples. Its practical applicability was validated through recovery tests.