Nanodiamond‐Based Quantum Sensing Reveals Changes in Endo‐Lysosomal Activity of Stimulated Cardiac Fibroblasts in a Cellular Fibrosis Model
Paper details
Section titled “Paper details”| Field | Value |
|---|---|
| Journal | Advanced Functional Materials |
| Published | 2026-01-28 |
| Authors | Aldona Mzyk, Ezgi Yilmaz, Giovanni D. Angelo, Kirstine Berg‐Sørensen |
| DOI | 10.1002/adfm.202528248 |
| Citations | 1 |
NV-center nanodiamonds detected passage-dependent changes in endo-lysosomal redox activity during cardiac fibroblast activation. At passage 2, T1 ranged from about 100 µs to about 200 µs. Lower T1 indicated higher local free radical and paramagnetic species levels.
The cardiac fibrosis model
Section titled “The cardiac fibrosis model”The authors cultured primary human cardiac fibroblasts at passages 2 and 5. Passage number represented replicative aging, not chronological aging of cardiac tissue. Cells were maintained at 37 °C and 5% CO2. Both substrates carried collagen I at 5 µg/cm². The soft substrate had a 40 µm PDMS layer with a Young’s modulus of 1.5 kPa. Uncoated glass served as the stiff substrate. Biochemical stimulation used 2 ng/mL TGF-β for 24 h before fluorescent nanodiamond exposure. The design separated substrate stiffness, TGF-β signaling, passage number, and particle exposure time.
Nanodiamond preparation and cell delivery
Section titled “Nanodiamond preparation and cell delivery”The fluorescent nanodiamonds (FNDs) had an average hydrodynamic diameter of 70 nm and a flake-like morphology. They were produced by the high-pressure high-temperature method followed by grinding. Electron irradiation used 3 MeV electrons at a fluence of 5 × 10^19 e cm⁻². Irradiation and annealing above 700 °C produced approximately 500 NV⁻ centers per particle. Oxidizing treatment left the particle surface oxygen terminated.
Before cell exposure, the authors sonicated FNDs for 15 min to limit aggregation. They dispersed particles in growth medium at 1 µg/mL. Cells received FNDs for 6 h at 37 °C and 5% CO2. Three PBS rinses removed excess particles before fresh complete medium was added.
Fluorescence imaging resolves particle uptake and localization
Section titled “Fluorescence imaging resolves particle uptake and localization”EEA1 staining marked early endosomes in fixed cells. LysoTracker Blue DND-22 at 500 nM marked late endosomes and lysosomes in live cells. Images used a Nikon Yokogawa CSU-W1 spinning-disk confocal system. A 100-fold oil objective had NA 1.45. Each Z-stack contained 40 images at 0.2 µm steps.
Fiji deconvolution and 3D segmentation identified FND objects. The intensity threshold was 40, which produced zero detections in negative-control images. The minimum size was 8 voxels. Eight-voxel objects were classified as single FNDs, and detected aggregates reached 180 voxels. An object was a connected voxel set, so it could represent one particle or several.
Each fluorescence experiment included at least six images and at least three cells per image. Three independent experiments were analyzed. DiAna distance analysis quantified FND association with each compartment. Two-way or three-way ANOVA used Tukey post hoc comparisons, and outliers were removed by IQR. Data were reported as mean ± standard deviation.
T1 relaxometry measures the redox signal
Section titled “T1 relaxometry measures the redox signal”The relaxometer used a 532 nm laser at 300 µW. Green pulses polarized NV⁻ spins into the bright m_s = 0 state. Each pulse lasted 2 µs, followed by dark periods from 7.2 to 720 µs. Fluorescence was counted during the first 0.6 µs of each pulse.
Particles with a count rate near three million were selected to avoid large aggregates. Each measurement lasted 3 min, and the sequence repeated several thousand times. At least 12 measurements were made for each biological condition.
Lower T1 corresponds to faster spin equilibration and higher nearby spin noise. The paper treated T1 as a combined readout of free radicals and paramagnetic species.
Stimulation changes particle handling and trafficking
Section titled “Stimulation changes particle handling and trafficking”Passage 2 cells on soft substrates contained about 150 FND objects per cell at 6 h without TGF-β. TGF-β reduced that count with p < 0.001. Stiff cells contained 50 to 70 objects per cell at 6 h, with no treatment difference. At 24 h, soft cells retained about 70 to 90 objects per cell. Stiff cells retained about 40 to 60. Soft cells carried more objects at both times, with p < 0.0001.
Passage 5 showed the same stiffness effect. Soft cells contained about 100 objects per cell at 6 h, while stiff cells contained 40 to 50. TGF-β lowered the passage 5 soft-substrate count at 6 h, with p < 0.0001. At 24 h, counts fell to 40 to 50 on soft substrates and 30 to 40 on stiff substrates. Soft cells again carried more objects, with p < 0.0001.
Mean object size remained about 10 to 30 voxels across conditions. No treatment, stiffness, or time effect was significant. Occasional aggregates reached 180 voxels. The authors proposed exocytosis and cell division as reasons for declining soft-substrate counts. They associated weak loss on stiff substrates with reduced exocytosis and division. Neither process was measured directly.
Stimulation also changed cell shape. At passage 2, TGF-β approximately doubled cell area on soft substrates, with p < 0.0001. Roundness fell from about 0.6 to 0.4 on soft substrates, with p < 0.001. At passage 5, TGF-β did not change area, but soft-substrate roundness fell from about 0.7 to 0.3, with p < 0.0001.
Early-endosome colocalization was 20% to 30% in most conditions. At passage 2, untreated cells on soft substrates reached 50% to 60% after 6 h. TGF-β reduced this to 20% to 25%, with p < 0.0001. At passage 5, colocalization was 15% to 30%. TGF-β increased it on stiff substrates at both times, with p < 0.01 at 6 h and p < 0.001 at 24 h.
Late-endosome and lysosome colocalization was about 50% to 60% at passage 2 after initial maturation. It remained near that range at passage 5. Stiff substrates produced small increases at 6 h, with p < 0.01, and 24 h, with p < 0.05. TGF-β had no significant effect on this colocalization.
The authors noted that uncolocalized FNDs could have escaped vesicles or occupied compartments missed by the dyes. The same FNDs required 24 h in H9c2 cells to reach a similar count. BEAS-2B cells internalized the same FND type within 2 h, while other cell types required longer times or higher concentrations.
Redox response depends on passage and stimulation
Section titled “Redox response depends on passage and stimulation”At passage 2, the highest T1 was about 200 µs on stiff substrates with TGF-β at 6 h. The lowest was about 100 µs on soft substrates without TGF-β at 6 h. TGF-β increased T1 on stiff substrates and on soft substrates at 24 h, each with p < 0.0001. Most 24 h values exceeded the corresponding 6 h values. These increases indicate lower inferred free radical and paramagnetic iron levels in the higher-T1 conditions.
At passage 5, TGF-β had no significant effect under any condition. Substrate stiffness became the main measured influence. Soft-substrate cells showed T1 of about 180 to 200 µs, especially at 6 h. Stiff-substrate cells showed about 100 to 120 µs at either time. The 24 h soft-substrate values stayed high, while stiff-substrate values did not change with time.
The direction of change depended on passage and treatment. Substrate stiffness alone cannot serve as a universal proxy for endo-lysosomal oxidative activity.
Limits for biological use and sensor development
Section titled “Limits for biological use and sensor development”Evidence remains a proof of concept in a two-dimensional primary-cell model. The study used one FND preparation, two passages, and measurements at 6 h and 24 h. Imaging captured snapshots rather than continuous organelle activity. The T1 signal reported a combined paramagnetic response and did not separate individual radical species or iron pools. FND counts could include aggregates, and uncolocalized particles could occupy other compartments.
The study did not directly measure ROS or RNS, lysosomal iron accumulation, ferritinophagy, membrane permeabilization, or ferroptosis. Cell passage, shape, and retention served as senescence-related indicators, but no senescence marker assay was reported. The authors proposed 3D cultures, organoids, drug screening, and other organ fibrosis models for future work.
For sensor development, the particle specification should include size, surface termination, NV loading, and aggregation control. Results should not be transferred to other particle sizes or diamond growth routes without new measurements.
View Original Abstract
ABSTRACT Despite a growing recognition of endo‐lysosomes as key regulators of cellular homeostasis, our understanding of their functional dynamics during cellular senescence, particularly in cardiac fibrosis, remains limited. Senescent cells exhibit profound changes in endo‐lysosomal redox status and iron dynamics, yet tracking these alterations in real time within living cells poses significant challenges. Conventional biochemical assays often lack spatial resolution and temporal sensitivity, while fluorescent probes can be hampered by photobleaching or interference from the complex endo‐lysosomal microenvironment. This has created a need for non‐invasive, high‐resolution tools. In this context, nanodiamonds containing nitrogen‐vacancy (NV) centers offer a promising solution for in vitro cell culture models. These quantum sensors are biocompatible, photostable, and capable of detecting changes in redox and iron dynamics at the nanoscale during the progression of senescence and fibrosis. In this work, we have shown that fluorescent nanodiamonds with NV centers could open new avenues for understanding how endo‐lysosomal activity changes during cardiac fibroblasts transdifferentiation to senescent myofibroblasts upon mechanical and biochemical stimulation.
Electronic Grade Intrinsic Diamond Epitaxial Wafer H Terminated Superior 100 Mosfet Ready Substrate
View Specs →
Free Standing Polycrystalline Cvd Diamond Membrane
View Specs →
High Concentration Quantum Grade Single Crystal Diamond
View Specs →References we cover
Section titled “References we cover”Citing papers we cover
Section titled “Citing papers we cover”- Construction optimization and functional applications of fluorescent nanodiamonds
- Quantum biosensing for skin cancer - NV-diamond magnetometry and nanothermometry for high-precision tumor margin mapping and microenvironment analysis at single-cell resolution