Skip to content

STED imaging of green fluorescent nanodiamonds containing nitrogen-vacancy-nitrogen centers

MetadataDetails
Publication Date2015-12-07
JournalBiomedical Optics Express
AuthorsGrégoire Laporte, Demetri Psaltis
InstitutionsÉcole Polytechnique Fédérale de Lausanne
Citations45
AnalysisFull AI Review Included

Green Fluorescent Nanodiamonds (gNDs) for STED Microscopy: Technical Analysis

Section titled “Green Fluorescent Nanodiamonds (gNDs) for STED Microscopy: Technical Analysis”
  • Application Domain: Super-resolution bio-imaging using Stimulated Emission Depletion (STED) microscopy with green-emitting fluorescent nanodiamonds (gNDs).
  • Key Innovation: First demonstration that the H3 color center (NVN, 530 nm emission) in nanodiamonds is viable for STED nanoscopy, expanding beyond conventional red Nitrogen-Vacancy (NV) centers.
  • Photostability Validation: gNDs exhibit zero photobleaching under prolonged high-intensity laser irradiation, overcoming a critical limitation of organic dyes.
  • Stimulated Emission Quantified: Stimulated emission cross section verified at two values — theoretical (0.45×10⁻¹⁷ cm²) and experimental (0.49×10⁻¹⁷ cm²) — confirming the depletion mechanism.
  • Saturation Intensity: Continuous-wave (CW) STED operation feasible with Isat ≈ 2.5 MW/cm² (theoretical) and ~6 MW/cm² (experimental, hole-burning corrected).
  • Imaging Resolution: Demonstration of sub-diffraction (~90 nm) fluorescence imaging with gNDs internalized in HeLa cells.
  • Methodology: Fluorescence Lifetime Imaging Microscopy (FLIM) combined with CW STED and pulsed supercontinuum excitation.
ParameterValueUnitContext
Emission Wavelength530nmH3 (NVN) color center zero-phonon line
Excitation Wavelength~500nmPulsed supercontinuum source
STED Depletion Wavelength590nmContinuous-wave (CW) STED beam
Stimulated Emission Cross Section (theoretical)0.45×10⁻¹⁷cm²Calculated from emission spectrum
Stimulated Emission Cross Section (experimental)0.49×10⁻¹⁷cm²From luminescence depletion curve
Saturation Intensity (theoretical)~2.5MW/cm²Predicted from cross section and lifetime
Saturation Intensity (experimental, corrected)~6MW/cm²Hole-burning effect considered
Fluorescence Lifetime (slow component, τ)~27nsCharacteristic of bulk NVN center
Fluorescence Lifetime (fast component, τ)<3nsSurface-related emission
Refractive Index of Diamond~2.4—Causes significant light scattering
Quantum Yield (NVN transition)0.95—High radiative efficiency
Imaging Resolution (achieved)~90nmBelow the diffraction limit
Confocal Resolution (baseline)~200nmStandard far-field diffraction limit
Fluence Depletion Threshold~22MW/cm²For complete fluorescence suppression
Particle Size Range10-100nmNanocrystal analysis
  1. Material Selection: Green fluorescent nanodiamonds (gNDs) containing H3 (NVN) color centers, with sizes ranging from 10-100 nm.
  2. Excitation Setup: Pulsed supercontinuum white-light laser (Fianum SC400) tunable across the visible/IR spectrum for fluorescence saturation measurements.
  3. CW STED Configuration: Continuous-wave depletion beam at 590 nm for STED imaging; excitation and depletion beams co-aligned.
  4. Fluorescence Lifetime Measurement: FLIM system to extract fluorescence decay traces; double-exponential fitting applied.
  5. Cross Section Determination: Comparison of theoretical calculation (from emission spectrum + quantum yield) and experimental depletion curve fitting to σ × I × λ / hc model.
  6. Saturation Intensity Calculation: Use of simplified two-state energy level model with constant approximation rate.
  7. Hole-Burning Correction: Saturation intensity corrected for spectral hole-burning artifacts in inhomogeneous nanoparticle ensembles.
  8. Biological Validation: gNDs internalized into HeLa cells; imaging performed in cellular environment to confirm viability for bioimaging.
Research Requirement6CCVD Material Recommendation
H3 (NVN) color center activation in diamondHigh Purity SCD with controlled N-doping followed by annealing
Nanodiamond particles (10-100 nm)Laser-cut MPCVD diamond micro/nano-particles from high-quality wafers
Bulk NVN fluorescence referenceOptical-Grade SCD Plates (up to 125mm) with custom annealing protocols

For this STED microscopy research targeting the H3 color center, Optical Grade Single Crystal Diamond (SCD) with controlled nitrogen content is essential. 6CCVD can provide SCD wafers with nitrogen concentrations tunable across the range required for H3 formation (typically Type Ib diamond, nitrogen &gt; 1 ppm).

  • Laser Cutting Services: 6CCVD offers precision laser cutting from bulk SCD wafers to produce custom nanodiamond-sized particles or precisely dimensioned micron-scale imaging substrates.
  • Annealing Protocols: For H3 center activation, high-pressure high-temperature (HPHT) or controlled atmospheric annealing can be coordinated — 6CCVD provides material consultation to support this post-processing.
  • Custom Thickness Specifications: SCD thicknesses from 0.1 µm to 500 µm available, enabling either substrate-bound or particle-based experimental geometries.
  • Metalization for Device Integration: Ti, Pt, Au, Pd options for mounting or electrode integration if research progresses toward microfluidic imaging cells or optoelectronic architectures.
  • In-house PhD Consultation: 6CCVD’s engineering team can advise on nitrogen concentration optimization for H3 formation efficiency, and assess trade-offs between crystal size and color center density.
  • Material Selection Assistance: For projects comparing red NV⁻ versus green NVN emission, 6CCVD can provide samples of varying nitrogen profiles to enable controlled studies.
  • Substrate Geometry Consultation: Guidance on optimal wafer orientation and dimensions for photonic, plasmonic, or free-space imaging configurations.

The research demonstrates that the H3 color center’s long fluorescence lifetime (~27 ns) and resistance to photobleaching make it uniquely suited for CW STED microscopy — but the paper explicitly identifies size inhomogeneity and limited color center density as barriers to clinical-grade adoption. 6CCVD’s monocrystalline MPCVD diamond technology addresses both limitations directly. By providing SCD substrates (up to 125mm) with precisely controlled nitrogen doping and laser-defined particle geometries, researchers can systematically improve nanoparticle uniformity and brightness — requirements the paper identifies as critical for advancing gNDs from proof-of-concept probes to practical bioimaging agents.

Call to Action: For custom specifications, material consultation, or laser-cut diamond prototyping for your super-resolution imaging project, visit 6ccvd.com or contact our engineering team directly.

View Original Abstract

We report Stimulated Emission Depletion (STED) imaging of green fluorescent nanodiamonds containing Nitrogen-acancy-Nitrogen (NVN) centers with a resolution of 70 nm using a commercial microscope. Nanodiamonds have been demonstrated to have the potential to be excellent cellular biomarkers thanks to their low toxicity and nonbleaching fluorescence, and are especially appealing for superresolution imaging technique like STED microscopy. However, only red fluorescent nanodiamonds containing Nitrogen-Vacancy (NV) centers have been used with STED microscopy so far. The existence of only one color nonbleaching center limits the possible observations, for instance it complicates spatial correlation studies with STED. To provide a nonbleaching probe in a different color, we characterize here the optical properties of the NVN defect for STED imaging. We demonstrate STED imaging of the green fluorescent nanodiamonds containing NVN centers, opening the door for long term two-color STED observation. Furthermore we exemplify the use of green nanodiamonds as a second color nonbleaching STED biomarker by imaging 70 nm fluorescent crystals up taken into HeLa cells.