  • Goal: Development of radiation-tolerant polycrystalline Chemical Vapor Deposition (pCVD) diamond tracking detectors for the High Luminosity Large Hadron Collider (HL-LHC), targeting operation up to 1017 hadrons/cm2.
  • Key Achievement: Verified that pCVD diamond detectors exhibit rate-independent signal pulse height up to 20 MHz/cm2 even after irradiation with 4 × 1015 n/cm2 — a critical breakthrough for high-luminosity environments.
  • Innovation: Fabrication and successful testing of the first pCVD 3D pixel detector with 50 µm × 50 µm cells, achieving 99.2% MIP detection efficiency at a 1500 e threshold, with charge collection exceeding 75% of deposited charge.
  • Application Scope: Planar pixel modules installed and operational in ATLAS (Diamond Beam Monitor) and CMS (BCM1F), with ongoing work on 3D pixel tracking for HL-LHC inner tracker upgrades.
  • Material Milestone: As-grown 12 cm diameter pCVD wafers now routinely achieve >400 µm charge collection distance with 5% uniformity across the wafer, with thickness specifications of 500 µm ± 10 µm.
  • 3D Electrode Fabrication: Laser-processed columns (2.5 µm diameter), with parallel development of plasma etching techniques for sub-5 µm diameter electrode holes.
  • Long-term Vision: Transfer mature 3D diamond technology to industry, scale sensors to 10 cm2 active areas, and qualify devices for operation across LHC Runs 4 and 5 without replacement.
ParameterValueUnitContext
Charge Collection Distance (as-grown)> 400µm12 cm pCVD wafer production
Charge Collection Uniformity5 (target <2 by 2021)%Across 12 cm wafer
pCVD Wafer Diameter12cmProduction reactor output
Sample Thickness (typical)500µmStandard detector grade
Sample Thickness (range)0.1 - 500µm6CCVD SCD/PCD capability match
Bias Voltage (standard operation)±1 to ±2V/µmEquivalent to ±500 V to ±1000 V
Bias Voltage (ATLAS DBM)500VField = 1 V/µm
Leakage Current (pre-irradiation threshold)< 10nAAfter Sr-90 pumping
Beam-induced Current Test20nAHV stability validation
3D Pixel Cell Size50 × 50 (target 25 × 25)µm3D pCVD pixel detector
3D Column Diameter2.5µmLaser-drilled electrodes
Plasma Etch Hole Diameter Target< 5µmAlternative fabrication route
Strip Pitch (strip modules)50µmWith 25 µm strip width
Strip Count per Module128channelsVA2.2 ASIC readout
ATLAS DBM Pixel Count26,880pixelsFE-I4 chip
ATLAS DBM Active Area16.8 × 20.0mm × mm250 µm × 50 µm pitch
ATLAS DBM Module Dimensions18 × 21mm × mm500 µm thick pCVD
Readout Noise (strip)~ 80e-Common mode corrected
Readout Noise (pad/pixel)~ 550e-2 pF input capacitance
Front-end Peaking Time~ 6nsCustom amplifier
Return-to-Baseline Time~ 16nsCustom amplifier
Particle Flux Tested (rate studies)5 kHz to 20MHz/cm2π+ at PSI HIPA
MIP Detection Threshold (3D pixel)1500e-CMS pixel electronics
3D Pixel Hit Efficiency99.2 (planar Si: 99.7)%Un-irradiated, 67 kHz/cm2
3D Charge Collection> 75 (target > 90)%Of deposited charge
Radiation Hardness (proven)2 × 1016p/cm2High-quality pCVD diamond
Radiation Hardness (program target)1017neq/cm2HL-LHC qualification
Damage Constant (800 MeV p)1.85 ± 0.13—Normalized to 24 GeV p
Damage Constant (70 MeV p)2.5 ± 0.4—Normalized to 24 GeV p
Damage Constant (25 MeV p)4.5 ± 0.6—Normalized to 24 GeV p
Damage Constant (fast neutrons)4.5 ± 0.5—Normalized to 24 GeV p
Surface Imperfection Target< 1/cm2Voids and defects
Working TemperatureCryogenic-capable—Dipole cryostat BLM
Front-end ASIC Technology65 nm CMOS—VLSI for HL-LHC BLM
  1. Beam Test Setup: Performed at PSI πM1 beamline with 260 MeV/c π+ at fluxes spanning 5 kHz/cm2 to 20 MHz/cm2, 19.8 ns bunch spacing.
  2. Telescope Reference Tracking: 100 µm × 150 µm CMS silicon pixel sensors with PSI46v2 readout chip for precise track reconstruction (~2 µm position resolution from 8-plane Si strip telescope).
  3. Readout Electronics: Custom-built amplifier (6 ns peaking time, 550 e- noise at 2 pF), DRS4 evaluation board digitizing at 2 GS/s.
  4. Sample Preparation: Hot acid cleaning → oxygen plasma etching → photolithographic lift-off metallization (50 µm pitch, 25 µm strip width) → Sr-90 “pumping” to fill intrinsic traps.
  5. Irradiation Facilities:
    • 800 MeV protons at LANSCE (Los Alamos)
    • 70 MeV protons at CYRIC (Tohoku University)
    • Fast reactor neutrons (>100 keV) at JSI TRIGA reactor
    • 24 GeV protons and 120 GeV/c hadrons at CERN SPS H6 beamline
  6. Radiation Damage Model: Linear dependence 1/λ = 1/λ0 + kφ, where λ is the mean free path and k is the damage constant extracted per sample.
  7. 3D Electrode Fabrication: Laser column drilling (current method) and plasma etching of sub-5 µm holes followed by conductive fill (development track).
  8. 3D Cell Geometry: Bias electrodes at 4 corners of cubic cells, readout electrodes at cell center; 3 × 2 ganging for CMS readout chip compatibility.
  9. Characterization Suite: Plasma processing → crossed-polarizer visible inspection for stress/defects → IV/CV curves with and without beam-induced current → charge collection and MFP measurements at 10 Hz to 10 kHz.
  10. Data Analysis Cuts: Removal of heavily ionizing saturated waveforms, calibration triggers, wrong-bucket triggers, and out-of-fiducial tracks; systematics estimated from data scatter below 80 kHz/cm2.
  • Electronic Grade Polycrystalline Diamond (PCD): Directly applicable for replicating and extending the RD42 results. 6CCVD PCD is available in thicknesses from 0.1 µm to 500 µm and substrates up to 10 mm, matching the 500 µm detector-grade material requirements with high charge collection distance.
  • Single Crystal Diamond (SCD): Suitable for reference samples and the parallel scCVD track in the radiation damage studies. 6CCVD SCD supports thicknesses 0.1 µm to 500 µm with Ra < 1 nm polishing.
  • Large-Format PCD Wafers: 6CCVD provides plates/wafers up to 125 mm, aligned with the 12 cm pCVD wafer scale referenced in the paper.
  • Laser-Cut 3D Cell Geometries: 6CCVD offers laser cutting and structuring services for the 50 µm × 50 µm and 25 µm × 25 µm cell patterns with 2.5 µm diameter column electrodes.
  • Custom Metalization: The paper uses photolithographic lift-off with strip patterns (50 µm pitch) and pixel metallizations for bump bonding to FE-I4 and CMS pixel ASICs. 6CCVD offers in-house metalization with Au, Pt, Pd, Ti, W, and Cu — enabling matched metallurgical stacks (e.g., Ti/Pt/Au for wire bonding, Ti/W for pixel bump-bonding compatibility).
  • Geometry Customization: Strip, pixel, and 3D cell patterns can be fabricated to specification, including the ATLAS DBM 18 mm × 21 mm footprint or the CMS BCM1F geometry.
  • Surface Preparation: 6CCVD’s polishing capabilities (Ra < 5 nm for inch-size PCD, Ra < 1 nm for SCD) support the surface quality required for low-leakage, high-uniformity detectors.
  • Wafer Preselection & QC: 6CCVD supports pre-shipment characterization protocols including IV/CV curves, charge collection measurements, and visual inspection under crossed polarizers for stress and void mapping.
  • Material Selection Consultation: 6CCVD’s in-house PhD engineering team can assist with selecting the optimal diamond grade (SCD vs. PCD), thickness, and metalization scheme for high-radiation particle detection applications spanning planar pad, strip, pixel, and 3D electrode architectures.
  • Prototype Development: From single-pixel test devices to full-size 10 cm2 3D pixel modules, 6CCVD supports iterative prototyping for HL-LHC-class detector R&D.
  • Cryogenic Operation Guidance: For applications requiring diamond sensor operation at cryogenic temperatures (e.g., dipole cryostat beam loss monitors), 6CCVD can advise on material behavior and integration considerations.

For custom specifications, advanced 3D cell fabrication, metalization stack design, or material consultation for radiation-hard tracking detector projects, visit 6ccvd.com or contact our engineering team directly.

View Original Abstract

The RD42 collaboration at CERN is leading the effort to develop radiation tolerant devices based on polycrystalline Chemical Vapor Deposition (pCVD) diamond as a material for tracking detectors operating in harsh radiation environments. Diamond has properties that make it suitable for such detector applications. During the last few years the RD42 group has succeeded in producing and characterising a number of devices to address specific issues related to their use at the LHC and HL-LHC. Herein we present the status of the RD42 project with emphasis on recent beam test results and our proposed three year research plan. In particular, we review recent results on the stability of signal size on incident particle rate in diamond detectors over a range of particle fluxes up to 20 MHz/cm2, on the radiation tolerance of CVD diamond, on the diamond work with ATLAS and CMS, on the results of 3D diamond detectors fabricated in pCVD diamond and on the work with diamond manufacturers. In addition, we present the details of our proposed 3 year program including milestones.