Single-longitudinal-mode diamond laser stabilization using polarization-dependent Raman gain

MetadataDetails
Publication Date2019-03-15
JournalOSA Continuum
AuthorsSoumya Sarang, Ondřej Kitzler, Oliver Lux, Zhenxu Bai, Robert J. Williams
InstitutionsMacquarie University, Deutsches Zentrum für Luft- und Raumfahrt e. V. (DLR)
Citations27
AnalysisFull AI Review Included
  • Objective: Develop a Hänsch-Couillaud (HC) variant locking mechanism for single-longitudinal-mode (SLM) continuous-wave diamond Raman lasers (DRL), bypassing the need for etalons, injection seeding, or ring cavities.
  • Key Innovation: The locking signal was generated using polarization-dependent Raman gain (gain anisotropy) and stress-induced birefringence in CVD single-crystal diamond (SCD) instead of conventional intracavity Brewster plates.
  • Performance Leap: Stable SLM output power was scaled from 2.1 W (free-running) to 7.2 W (stabilized), with sustained stability improving from “tens of seconds” to 120 seconds at 4.5 W.
  • Crystal Specifications: The research utilized an 8 × 4 × 1.2 mm3 low-nitrogen, low-birefringence SCD with propagation along the <110> axis, anti-reflection (AR) coated at both pump (1064 nm) and Stokes (1240 nm) wavelengths.
  • Critical Findings: The 1064 nm pump source (Yb-fiber amplified, 50 W, M2 = 1.05) was polarized along the <111> axis for maximum Raman gain, while the diamond’s intrinsic birefringence (∆n ≈ 5 × 10−6) and Raman pump-depletion rotation provided the polarization-dependent loss mechanism essential for the HC locking signal above threshold.
  • Limitation & Next Step: Locking was ultimately restricted by the piezo-stage slew rate (154 Hz) and low cavity finesse at the pump wavelength. The paper mathematically demonstrates that increasing ∆n to 1.7 × 10−5 - 3.2 × 10−5 would yield a robust dispersion-like locking signal.
ParameterValueUnitContext
Pump Source1064nmYb-fiber amplified DFB laser (CW)
Pump Power50WMaximum available output
Pump Linewidth5MHzNarrower than 45 GHz Raman gain bandwidth
Beam Quality (M²)1.05-Near diffraction-limited
Stokes Wavelength1240nmFirst Stokes shift
Threshold Pump Power23WStokes lasing threshold
Slope Efficiency70%Unstabilized CW operation
SLM Power (Free-running)2.1WBaseline before active locking
SLM Power (Stabilized)7.2WMaximum achieved with HC locking
SLM Stability Duration120sAt 4.5 W output power
Wavelength Stability125MHzFluctuation range over 2 mins
Raman Gain Bandwidth (FWHM)45GHzHomogeneous broadening regime
Cavity Length102mmNear-concentric standing-wave cavity
Mirror Radius of Curvature50mmConcave input/output couplers
Diamond Dimensions8 × 4 × 1.2mm³Length × Width × Thickness
Diamond Birefringence (∆n)5 × 10−6-Stress-induced, near-IR
Propagation Direction<110>-Crystallographic orientation
Pump Polarization<111>-Orientation for maximum Raman gain
Input Coupler (IC) Trans.99.26 (1064nm) / 0.06 (1240nm)%Highly transmitting / Highly reflective
Output Coupler (OC) Trans.0.5 (1240nm)%Partially transmitting at Stokes
AR Coating Reflectivity< 1 (1064nm) / < 0.25 (1240nm)%Diamond end-face coatings
Round-Trip Dephasing (∆)0.5radCalculated birefringence-induced phase
PZT Travel Range20µm0 - 75 V applied voltage
PZT Slew Rate154HzLimiting factor for locking bandwidth
Intracavity Loss (Absorption)0.017%/mmAt pump wavelength
Intracavity Loss (Reflection)0.1%/faceAt crystal end-faces
  1. Cavity Design: Constructed a simple standing-wave, near-concentric cavity (102 mm length, 50 mm ROC mirrors) devoid of frequency-selective elements to test the HC locking hypothesis.
  2. Crystal Preparation: Used low-nitrogen, low-birefringence CVD-grown single-crystal diamond, cut for <110> propagation, with AR coatings on both faces to minimize intracavity losses.
  3. Pump Alignment: Focused the 1064 nm pump beam (50 mm focal length lens, 40 µm spot radius) into the center of the diamond with polarization oriented along the <111> axis for maximum stimulated Raman scattering efficiency.
  4. Locking Signal Generation: Implemented a Hänsch-Couillaud setup using a quarter-wave plate (QWP), polarizing beam splitter (PBS), and two photodiodes to analyze residual pump polarization after double-passing the cavity.
  5. Theoretical Modeling: Developed a MATLAB model based on four coupled differential equations (Eqs. 4a-4d) to simulate pump depletion and Stokes generation for orthogonal polarizations, validating that polarization rotation above threshold generates the locking signal.
  6. Active Stabilization: Drove a piezoelectric translation stage (PZT) holding the output coupler via a PID controller (Laselock digital), targeting the zero-crossing of the locking signal.
  7. Spectral Characterization: Monitored output using a scanning Fabry-Perot interferometer (67 MHz resolution, 10 GHz FSR), an optical spectrum analyzer (0.05 nm resolution), and a Bristol 771A-NIR laser spectrum analyzer for wavelength stability tracking.

This research highlights the critical role of high-purity, low-loss, and precisely engineered Single Crystal Diamond (SCD) in advancing high-power, single-frequency laser architectures. Below is how 6CCVD directly addresses the requirements identified in this paper.

  • Applicable Materials: To replicate or extend this research, Optical Grade Single Crystal Diamond (SCD) is required. The study specifically utilized low-nitrogen, low-birefringence CVD diamond to minimize parasitic absorption and optical loss. 6CCVD specializes in manufacturing ultra-low-loss SCD substrates and plates engineered explicitly for high-power laser gain media where thermal and optical stability are paramount.
  • Customization Potential: The paper utilized a specific 8 × 4 × 1.2 mm3 geometry cut along the <110> axis with custom AR coatings (R < 1% at 1064 nm, R < 0.25% at 1240 nm). 6CCVD offers custom diamond shaping and laser cutting up to wafer-scale dimensions, alongside in-house dielectric coating capabilities to meet these exacting specifications. Furthermore, 6CCVD provides custom metallization (e.g., Ti/Pt/Au) which is frequently essential for securely mounting diamond crystals onto thermal heat sinks or piezo-electric transducers (PZT) without introducing mechanical stress that could alter the birefringence profile.
  • Engineering Support: The authors identified that increasing the diamond’s intrinsic birefringence (∆n) to the 10−5 range would significantly improve the HC locking signal. 6CCVD’s in-house PhD engineering team can collaborate on material selection, advising on the trade-offs between stress-induced birefringence control and crystal orientation (<110>, <111>, <100>) to optimize Raman gain anisotropy for next-generation stabilized laser cavities. Whether the application is spectroscopy, gravitational wave sensing, or LIDAR, our experts can tailor the SCD optical and mechanical properties to your project requirements.
  • Call to Action: For custom specifications, AR coating designs, or material consultation regarding your diamond Raman laser architecture, visit 6ccvd.com or contact our engineering team directly.
View Original Abstract

We report a novel cavity feedback mechanism for stabilizing single-longitudinal-mode (SLM) operation of diamond Raman lasers. Polarization-dependent Raman gain and in-grown stress birefringence in diamond were investigated as sources for Hänsch-Couillaud-type locking signals. The power range of SLM operation increased from 2.1 W to 7.2 W, compared to the free-running laser, for a simple standing-wave laser cavity without frequency-selective elements. Methods for further increasing power range and frequency stability are discussed.