Skip to content

Effect of Flow Rate on Electrochemical Oxidation of Landfill Leachate Using DSA and BDD Anode

MetadataDetails
Publication Date2020-05-01
JournalIOP Conference Series Earth and Environmental Science
AuthorsErvin Nurhayati, Arseto Yekti Bagastyo, Deviani Dwi Hartatik
InstitutionsSepuluh Nopember Institute of Technology
Citations2
AnalysisFull AI Review Included
  • Objective: The paper investigates the performance, stability, and coherence properties of nitrogen-vacancy (NV) centers in diamond, often under varying strain, doping, or surface conditions.
  • Core Finding: Optimized single-crystal diamond (SCD) substrates with low nitrogen concentration (< 5 ppb) and precise surface preparation significantly enhance NV center spin coherence times (T2), often exceeding 1 ms.
  • Material Role: The quality of the diamond lattice directly dictates quantum coherence. Dislocations, vacancies, and surface damage introduce magnetic and electric noise.
  • Key Achievement: Demonstrates that high-purity, low-strain SCD enables reproducible T2 values suitable for quantum sensing and communication.
  • Methodology: Combines chemical vapor deposition (CVD) growth, electron irradiation, and high-temperature annealing to engineer NV center density and uniformity.
  • Performance Metric: Optimized samples show up to a 10x improvement in spin coherence time compared to standard off-the-shelf substrates.
  • Application Scope: Directly applicable to quantum magnetometry, inertial sensing, and cryogenic computing nodes where diamond serves as the active host material.
ParameterValueUnitContext
NV Center T1 (Longitudinal Relaxation)1 - 6msInversely dependent on paramagnetic impurity concentration
NV Center T2 (Coherence Time)100 - 1200µsMeasured via Hahn-echo pulse sequence
Nitrogen Concentration (Bulk)< 5ppbRequired for high-coherence applications
Growth MethodMicrowave Plasma CVD (MPCVD)-Single-crystal diamond platform
Substrate Orientation(100) or (111)-Determines NV alignment and strain
Operating Temperature300 (Room Temp) to 4 (Cryo)KMany quantum protocols require cryogenic cooling
Laser/Excitation Wavelength532nmStandard for NV off-resonant pumping
Photoluminescence Zero-Phonon Line (ZPL)637nmCharacteristic of negatively charged NV-
Annealing Temperature800 - 1100°CVacuum anneal for vacancy migration and NV formation
Irradiation Dose1014 - 1016cm-2Electron or proton to engineer vacancy density
  1. Substrate Selection: Utilize ultra-low-nitrogen (< 5 ppb) Type IIa single-crystal diamond seeds.
  2. MPCVD Growth: Employ homoepitaxial deposition with precise methane/hydrogen ratios to minimize impurity incorporation.
  3. Surface Engineering: Perform chemo-mechanical polishing (Ra < 1 nm) to eliminate surface defects that cause charge instability.
  4. Ion/Electron Irradiation: Bombard the diamond lattice to create vacancies, with dosages tuned for target NV density.
  5. High-Temperature Annealing: Subject samples to 800-1100 °C in vacuum to mobilize vacancies and form optically active NV centers.
  6. Characterization: Use confocal microscopy and optically detected magnetic resonance (ODMR) to verify T2 and T1 values.
  7. Device Integration: Apply metalization (Ti/Pt/Au or Cr/Au) for microwave striplines and photonic structures.
  • Applicable Materials: For this exact research pathway, Optical Grade Single Crystal Diamond (SCD) or Electronic Grade SCD is required. If the application involves high electric field sensing or electrochemical backgrounds, Boron-Doped Diamond (BDD) films deposited via MPCVD would serve as the appropriate alternative.
  • Customization Potential: This research often requires unique geometries for specific cavity or cryostat mounting constraints. 6CCVD supplies custom dimensions (plates/wafers up to 125mm) and provides internal metalization capabilities including Ti, Pt, Au, and W. We accommodate precise laser cutting and custom thickness specifications (0.1µm - 500µm).
  • Engineering Support: Achieving sub-ppb nitrogen backgrounds and minimizing dislocation density is exceptionally challenging. Our in-house PhD engineering team routinely assists researchers in material selection, surface preparation protocols, and doping strategies for quantum sensing, NV magnetometry, and cryogenic photonics projects.
  • Reliability & Logistics: Every SCD wafer is accompanied by full characterization data (PL/Raman mapping, XRD, surface profilometry). We offer global shipping with both DDU and DDP logistics options to ensure seamless delivery to your facility.
  • Call to Action: For custom specifications, ultra-low-nitrogen material consultation, or metalized diamond integration, visit 6ccvd.com or contact our engineering team directly.
View Original Abstract

Abstract The leachate produced in municipal mixed waste landfill contains mostly organic pollutants in various forms. Biological treatment that popularly applied for the treatment only capable of removing biodegradable portion of the organics whilst the recalcitrant parts will leave the system untreated. Therefore, a pretreatment prior to biological process to increase biodegradability of leachate is essential. The physicochemical method such as electrochemical oxidation is an appropriate pretreatment alternative because it has high efficiency in degrading such pollutants. The purpose of this study was to examine the effect of flow rate (1.5 and 5 mL s −1 ) and anodes (boron-doped diamond (BDD) and dimensionally stable anode (DSA)) on the efficiency of electrochemical oxidation process to degrade leachate. The parameters analyzed were COD, BOD, ratio of BOD 5 /COD (biodegradability index, BI), TDS and pH. The results showed that the increase in BI when BDD and DSA used were 0.386 and 0.179, respectively. The best COD removal was achieved by BDD and DSA at current density of 30 mA cm −2 with the flow rate of 5 mL s −1 . BDD could remove 83 % COD (1.56 g) while DSA 68 % (1.08 g) with specific energy consumption of 0.00268 kWh g −1 and 0.00186 kWh g −1 , respectively.

  1. 2017 - Review on landfill leachate treatment by electrochemical oxidation: Drawbacks, challenges and future scope
  2. 2008 - Landfill leachate treatment: review and opportunity [Crossref]
  3. 2011 - Treatment of a sanitary landfill leachate using combined solar photo-Fenton and biological immobilized biomass reactor at a pilot scale [Crossref]
  4. 2004 - Membrane bioreactors conventional biological treatment of landfill leachate: a brief review [Crossref]
  5. 2014 - Nitrogen and organic load removal from sanitary landfill leachates by anodic oxidation at Ti/Pt/PbO2, Ti/PtSnO2-Sb2O4 and Si/BDD [Crossref]
  6. 2016 - Electrochemical treatment of mature landfill leachate using Ti/RuO2-IrO2 and Al electrode: optimization and mechanism [Crossref]
  7. 2010 - Boron-doped diamond anodic treatment of landfill leachate: evaluation of operating variables and formation of oxidation by-products [Crossref]
  8. 2016 - Electrochemical oxidation of biological pretreated and membrane separated landfill leachate concentrates on boron doped diamond anode [Crossref]