Skip to content

Forty-fold Speedup of NV− Center Magnetometry with Sequential Bayesian Experiment Design

MetadataDetails
Publication Date2021-01-01
JournalConference on Lasers and Electro-Optics
AuthorsSergey Dushenko, Sean M. Blakley, Kapildeb Ambal, R. D. McMichael
InstitutionsWichita State University, National Institute of Standards and Technology

In magnetometry using quantum defects in diamond (NV − centers), we demonstrate forty-fold speedup with sequential Bayesian experiment design as compared with conventional NV- magnetometry using frequency-swept measurements.