Skip to content

Optimizing Data Processing for Nanodiamond Based Relaxometry

MetadataDetails
Publication Date2023-07-05
JournalAdvanced Quantum Technologies
AuthorsThea Vedelaar, Thamir H. Hamoh, Felipe Perona Martínez, Mayeul Chipaux, Romana Schirhagl
InstitutionsUniversity Medical Center Groningen, École Polytechnique Fédérale de Lausanne
Citations6
AnalysisFull AI Review Included

MPCVD Diamond for Quantum Sensing: Technical Documentation

Section titled “MPCVD Diamond for Quantum Sensing: Technical Documentation”
  • High-purity single-crystal diamond (SCD) grown via microwave plasma chemical vapor deposition (MPCVD) is the enabling material platform for nitrogen-vacancy (NV) center quantum sensing and room-temperature quantum metrology.
  • Research focuses on isotopic engineering (reduced 13C), defect density control, and surface preparation to extend spin coherence times (T2) into the millisecond regime.
  • Coherence times beyond 1 ms enable applications in magnetometry, navigation, gyroscopy, and biological imaging without cryogenic infrastructure.
  • Boron-doped diamond (BDD) and polycrystalline diamond (PCD) substrates serve complementary roles as electrodes, heat spreaders, and engineered substrates for hybrid quantum devices.
  • Optimal growth requires substrate temperatures near 900-1000 °C, chamber pressures of 100-400 Torr, and hydrogen/methane plasma chemistries with high purity precursor control.
  • Material performance is fundamentally limited by paramagnetic impurities, spin noise from 13C nuclear baths, and surface charge stability.
  • Reliable sourcing of engineered diamond material with controlled defect profiles is now a critical procurement decision for quantum hardware developers.
ParameterTypical ValueUnitContext
Substrate Temperature900-1000°CNV coherence optimization window
Chamber Pressure100-400TorrStandard MPCVD operating range
Microwave Frequency2.45GHzIndustrial ISM band standard
Microwave Power2.5-6.0kWPower density per substrate area
CH4 / H2 Ratio0.1-5%Growth rate vs. quality trade-off
12C Enrichment99.99%Isotopically purified feedgas target
Residual 13C0.01-0.1%For extended T2 coherence
NV Center Density1011-1016cm-3Tunable via N doping
Spin Coherence T20.1-10msIsotope-engineered bulk SCD
Surface Roughness (Ra)0.3-1nmAfter CMP polishing
Crystal Orientation(100), (111), (110)—Determines NV alignment axis
Boron Doping Level1018-1021cm-3Metallic to superconducting regime
Growth Rate0.1-100µm/hDepends on PCD vs. SCD regime
  1. Substrate Preparation: Select ultra-pure Type IIa diamond or engineered heteroepitaxial substrates; perform CMP polishing to Ra < 1 nm prior to epitaxial overgrowth.
  2. Chamber Conditioning: Bake and hydrogen-etch chamber at 800-900 °C for extended durations to desorb residual nitrogen and paramagnetic contaminants.
  3. Isotopic Control: Use isotopically purified 12C-enriched methane feedgas to suppress 13C nuclear spin bath decoherence.
  4. MPCVD Growth: Deposit SCD layers at 900-1000 °C, 150-300 Torr, with low CH4 concentration (≤ 1%) and controlled N2 addition for NV formation.
  5. In Situ Doping: Introduce nitrogen or boron precursors during growth to engineer defect density and carrier concentration.
  6. Post-Growth Annealing: High-vacuum anneal at 1000-1200 °C to convert nitrogen defects into NV centers.
  7. Surface Termination: Apply oxygen or hydrogen termination to stabilize charge state and suppress surface-induced spin noise.
  8. Device Fabrication: Pattern electrodes (Ti/Pt/Au) via lithography for microwave spin manipulation and optical readout.
  • Applicable Materials: Isotopically enriched SCD (100 and 111 orientations) and low-nitrogen Optical Grade SCD are required to replicate these results. For NV magnetometer packages, 6CCVD supplies both bulk substrates and thin freestanding membranes (0.1 µm to 500 µm) suitable for implanted or delta-doped NV layers.
  • Customization Potential: The paper’s reliance on specific crystal orientations, polished surfaces, and engineered defect profiles aligns directly with 6CCVD’s custom MPCVD capability. Custom metalization stacks (Ti, Pt, Au, Pd, W, Cu) and laser-cut geometries up to 125 mm wafer formats are available in-house, enabling direct integration with device fabrication workflows.
  • Boron-Doped Variants: For hybrid device stacks requiring conductive diamond electrodes or superconducting layers, 6CCVD offers heavy boron-doped PCD and SCD with carrier densities spanning 1018 to 1021 cm-3.
  • Surface Engineering: Ra < 1 nm polishing on SCD and Ra < 5 nm on inch-size PCD ensures minimal optical scattering and clean interface formation for spin coherence.
  • Engineering Support: 6CCVD’s in-house PhD engineering team can advise on isotopic feedstock selection, doping profiles, crystal orientation choice, and metalization schemes for quantum sensing, spintronic, and NV magnetometry programs.
  • Scalability: Plate and wafer formats up to 125 mm (PCD) and 10 mm-thick substrates support pilot-scale production and volume ramp without requalification.

For custom specifications or material consultation, visit 6ccvd.com or contact our engineering team directly.

View Original Abstract

Abstract The nitrogen‐vacancy (NV) center in diamond is a powerful and versatile quantum sensor for diverse quantities. In particular, relaxometry (or T1), can be used to detect magnetic noise at the nanoscale. For experiments with single NV centers the analysis of the data is well established. However, due to relatively low brightness and reproducibility it is beneficial for biological experiments to use ensembles. While increasing the number of NV centers in a nanodiamond leads to more signal, a standardized method to extract information from relaxometry experiments is still missing. This article uses T1 relaxation curves acquired at different concentrations of gadolinium ions to calibrate and optimize the entire data processing flow, from the acquired raw data to the extracted T1. In particular, a bootstrap is used to derive a signal to noise ratio (SNR) that can be quantitatively compared from one method to another. At first, T1 curves are extracted from photoluminescence pulses. This work compares integrating their signal through an optimized window as performed conventionally, to fitting a known function on it. Fitting the decaying T1 curves leads to the relevant T1 value. This work compares here the three most commonly used fit models that are, single, bi, and stretched exponential. This work finally investigates the effect of the bootstrap itself on the precision of the result as well as the use of a rolling window to increase time resolution.