Skip to content

Miniaturized magnetic-field sensor based on nitrogen-vacancy centers

MetadataDetails
Publication Date2025-10-24
JournalPhysical Review Applied
AuthorsStefan Johansson, Dennis Lönard, Isabel Cardoso Barbosa, Jonas Gutsche, Jonas Witzenrath
AnalysisFull AI Review Included
  • Application: Fiber-based endoscopic magnetic-field sensor utilizing nitrogen-vacancy (NV) centers in diamond for vector magnetometry.
  • Core Achievement: Shot-noise-limited sensitivity of 5.9 nT / √Hz achieved with a compact, fully integrated 1.25 mm tip diameter sensor head (total head volume of 52.8 mm3).
  • Operating Parameters: Demonstrated at low microwave (MW) power of 50 mW and optical laser power of 2.15 mW (520 nm excitation).
  • Spatial Resolution: Intrinsic spatial resolution defined by a 15 µm single-crystal diamond (SCD) microdiamond.
  • Structural Innovation: Direct laser writing (DLW) of a silver antenna structure alongside a polymer waveguide to securely fix the diamond to the fiber facet.
  • Background Reduction: Dual-fiber configuration reduces detection-fiber autofluorescence by a factor of ~800, enabling future integration of sub-100 nm diamond nanocrystals.
  • Method: Optically Detected Magnetic Resonance (ODMR) spectroscopy with lock-in amplification for vector field reconstruction.
ParameterValueUnitContext
Sensor Head Tip Diameter1.25mmEndoscopic probe physical dimension
Total Sensor Head Volume52.8mm3Includes housing, MW antenna, and fiber mount
Sensor Diamond Size15µmSingle crystal diamond (SCD) used as sensing element
NV Center Doping~3.5ppmNitrogen concentration in the diamond lattice
Laser Excitation Wavelength520nmOptical pumping for NV spin initialization/readout
Optical Laser Power2.15 - 2.2mWPower delivered to the diamond at the fiber tip
MW Resonance Frequency2.8 ± 0.2GHzS11 resonance of the laser-written silver antenna
Applied MW Power50mWMicrowave power for spin manipulation
Zero-Field Splitting (D)2.87GHzStandard NV Hamiltonian parameter
Gyromagnetic Ratio (γ)28.03GHz / TNV center electron spin response
Lock-in Sensitivity51.8nT / √HzContinuous ODMR sweep sensitivity
Shot-Noise (SN) Sensitivity5.9nT / √HzBest axis sensitivity (single-fiber config)
Volumetric SN Sensitivity7.8pT · mm3/2 / √HzNormalized to 15 µm diamond sphere volume
LIA Modulation Bandwidth80.9Hz3-dB bandwidth of low-pass filter
Minimum Allan Deviation21.3nTLong-term stability at 41 s integration time
Autofluorescence Reduction~800factorLaser power reduction in detection fiber (dual-fiber)
  • Diamond Integration: Positioned a 15 µm single-crystal diamond 50 µm above the multimode (MM) fiber core using a 5-axis stage.
  • Polymer Waveguide Fabrication: Direct laser writing (DLW) of a cone structure using IP Visio photoresist to guide light between the fiber core and diamond.
  • Microwave Antenna Fabrication: DLW of silver resist to create antenna structures; optionally galvanized (0.7 V for 2 min) to reduce ohmic resistance from ~35 Ω to ~3.3 Ω.
  • Optical Setup: Modular anodized aluminum enclosure (215 × 150 × 58 mm3) utilizing polarizing beam cubes and long-pass filters (>650 nm).
  • Spin Manipulation: Continuous Wave (CW) ODMR spectroscopy with frequency modulation for lock-in amplifier (LIA) detection.
  • Data Processing: Levenberg-Marquardt algorithm fitting derivatives of 8 Lorentzian distributions to map resonance shifts.
  • Vector Field Reconstruction: Calculation of upper/lower resonance frequencies to derive the absolute magnetic field vector and direction across four NV orientations.

To replicate or extend the findings of this paper regarding miniaturized fiber-based NV magnetometry, 6CCVD provides the following material platforms and engineering services:

  • Applicable Materials:

    • Optical Grade Single Crystal Diamond (SCD): Essential for the 15 µm microdiamond sensing element. 6CCVD offers SCD plates/wafer pieces down to the 10 - 100 µm size range (custom laser cutting available).
    • Custom NV-Doped SCD: We provide tailored nitrogen doping levels (typically 1 ppm to 100 ppm) to optimize the trade-off between fluorescence yield and spin coherence.
    • Polycrystalline Diamond (PCD): For applications requiring ensemble sensing or alternative form factors, our PCD plates can be custom-processed.
  • Customization Potential:

    • Dimensional Flexibility: Need a specific diamond geometry (e.g., 100 nm to 125 mm)? 6CCVD specializes in custom laser cutting and shaping of SCD and PCD materials.
    • Thin-Film Processing: For advanced integration or NV center engineering at the surface, we provide SCD membranes down to 0.1 µm thickness.
    • Metallization: The paper relies on a custom-written silver antenna. If your design requires conventional, highly repeatable thin-film metallization, 6CCVD offers in-house deposition of Ti, Pt, Au, W, Pd, and Cu.
  • Engineering Support:

    • 6CCVD’s in-house PhD engineering team is equipped to consult on material selection for quantum sensing, ODMR prototyping, and cryogenic-to-high-temperature sensor operation. We assist researchers in matching NV doping concentrations to specific sensitivity and resolution targets.
  • Call to Action:

    • For custom specifications, material consultation, or quotes on microdiamond sensors, visit 6ccvd.com or contact our engineering team directly.
View Original Abstract

The nitrogen-vacancy (NV) center in diamond is a prime candidate for quantum sensing technologies. Here, we present a fully integrated and mechanically robust fiber-based endoscopic sensor with a tip diameter of <a:math xmlns:a=“http://www.w3.org/1998/Math/MathML” display=“inline”> <a:mrow> <a:mn>1.25</a:mn> </a:mrow> <a:mspace width=“0.1em”/> <a:mi>mm</a:mi> </a:math> . On its tip, a direct laser-writing process is used to secure a diamond containing NV centers above the fiber’s core inside a polymer structure. Additionally, a metallic direct laser-written antenna structure next to the fiber facet allows efficient microwave manipulation of NV-center spins. The sensor achieves a shot-noise-limited magnetic-field sensitivity of <d:math xmlns:d=“http://www.w3.org/1998/Math/MathML” display=“inline”> <d:mrow> <d:mn>5.9</d:mn> </d:mrow> <d:mspace width=“0.1em”/> <d:mi>nT</d:mi> <d:mo>/</d:mo> <d:msqrt> <d:mi>Hz</d:mi> </d:msqrt> </d:math> using a <g:math xmlns:g=“http://www.w3.org/1998/Math/MathML” display=“inline”> <g:mn>15</g:mn> <g:mstyle displaystyle=“false” scriptlevel=“0”> <g:mtext>−</g:mtext> </g:mstyle> <g:mtext fontfamily=“times”>μ</g:mtext> <g:mrow> <g:mrow> <g:mi mathvariant=“normal”>m</g:mi> </g:mrow> </g:mrow> </g:math> -sized microdiamond at a microwave power of <m:math xmlns:m=“http://www.w3.org/1998/Math/MathML” display=“inline”> <m:mn>50</m:mn> <m:mspace width=“0.1em”/> <m:mi>mW</m:mi> </m:math> and an optical power of <p:math xmlns:p=“http://www.w3.org/1998/Math/MathML” display=“inline”> <p:mrow> <p:mn>2.15</p:mn> </p:mrow> <p:mspace width=“0.1em”/> <p:mi>mW</p:mi> </p:math> . Using lock-in techniques, we measure a sensitivity of <s:math xmlns:s=“http://www.w3.org/1998/Math/MathML” display=“inline”> <s:mrow> <s:mn>51.8</s:mn> </s:mrow> <s:mspace width=“0.1em”/> <s:mi>nT</s:mi> <s:mo>/</s:mo> <s:msqrt> <s:mi>Hz</s:mi> </s:msqrt> </s:math> . Furthermore, we introduce a dual-fiber concept that enables, in combination with a direct laser-written structure, independent guiding of excitation and fluorescence light and thus reduces background autofluorescence. Moreover, controlled guiding of excitation light to the diamond while avoiding sample illumination may enable operation in light-sensitive environments such as biological tissue. While the demonstrated sensitivity is achieved using a single-fiber configuration, the dual-fiber approach provides a path toward integrating smaller diamonds, where autofluorescence would otherwise limit performance. We demonstrate the capability of vector magnetic-field measurements in the type of magnetic field used in state-of-the-art ultracold quantum gas experiments, opening a potential arena in which high resolution and high sensitivity are required.