Skip to content

Nanodiamond Relaxometry-Based Detection of Free-Radical Species When Produced in Chemical Reactions in Biologically Relevant Conditions

MetadataDetails
Publication Date2020-12-03
JournalACS Sensors
AuthorsFelipe Perona Martínez, Anggrek Citra Nusantara, Mayeul Chipaux, Sandeep K. Padamati, Romana Schirhagl
InstitutionsUniversity Medical Center Groningen, École Polytechnique Fédérale de Lausanne
Citations101
AnalysisFull AI Review Included
  • Core Innovation: First real-time, label-free in situ detection of free-radical species (specifically hydroxyl radicals, *OH) using nanodiamond T1 relaxometry during active chemical reactions.
  • Sensing Modality: Utilizes the longitudinal spin relaxation time (T1) of nitrogen-vacancy (NV) centers in nanodiamonds, bypassing the slow accumulation periods required by traditional fluorescent probes (e.g., HPF required 14 hours vs. a few minutes for the NV method).
  • Reaction Targets: Two biologically relevant pathways were monitored: UV-induced photolysis of H2O2 and the iron-catalyzed Haber-Weiss reaction (using Fe(ClO4)2).
  • Detection Performance: Achieved detection limits down to the nanomolar (nM) range across a measurement span of 0 to 108 nM, with typical T1 baseline times of a few 100 µs.
  • Counterintuitive Finding: Smaller nanodiamonds (40-120 nm range) containing dense NV ensembles exhibited higher T1 times than larger particles, contrary to conventional surface-noise assumptions.
  • Reversibility Advantage: NV centers do not undergo irreversible chemical reactions with radicals, offering reversible, repeatable sensing over time.
  • Environmental Robustness: Validated sensing performance in biologically relevant media including PBS buffer, cell medium (containing salts like Na+, K+, Cl-), and gadolinium (Gd3+) spin-label environments.
ParameterValueUnitContext
Nanodiamond Size Range40 - 120nmParticle size distribution for NV ensemble probes
NV Pump Laser Wavelength532nmOptical initialization of NV ground state
T1 Relaxation Time (Baseline)~100 - 300µsTypical dark-state duration before read-out
Detection Range0 - 108nMConcentration span tested for Gd3+ and *OH detection
Limit of Detection (LOD)~2 (down to nM range)µmol (*OH)Minimum hydroxyl radical concentration detected
Optimal Dark Time (Photolysis)~150µsMaximizes intensity differential between UV On/Off states
Radical Generation Method 1UV Photolysis—Cleavage of H2O2 precursor
Radical Generation Method 2Haber-Weiss Reaction—Fe(ClO4)2 catalysis of H2O2
Spin Label TestedGadolinium (Gd3+)—Reference contrast agent in varying ionic environments
Measurement TimeFew minutesminCompared to 14 h for conventional HPF probe
Surface ChemistryUncoated / Lipid-coated—Tested for colloidal stability and biocompatibility
Operating TemperatureAmbient (~25)°CRoom-temperature quantum sensing
  1. Probe Preparation: Selection of fluorescent nanodiamonds (40-120 nm) with dense NV ensembles, used both as-grown and with lipid-coating surface functionalization.
  2. Optical Initialization (Pumping): NV centers pumped into the ground state using a 532 nm laser pulse.
  3. Dark Time Evolution: Variable dark time interval (tdark) applied to allow spin-lattice relaxation (T1) to proceed, during which external spin noise (from radicals or Gd3+) perturbs the NV spin state.
  4. Fluorescence Read-Out: Second laser pulse reads the NV brightness, which correlates to magnetic noise in the local environment.
  5. T1 Curve Fitting: T1 relaxation curves extracted across varying dark times and fit to mono- or biexponential decay models.
  6. Hydroxyl Radical Generation: *OH species produced via two routes: (a) UV irradiation of H2O2 solution; (b) Fenton-type chemistry via Fe(ClO4)2 + H2O2.
  7. Environmental Control: Measurements conducted in pure water, PBS buffer, full cell culture medium (ionic strength up to ~150 mM NaCl equivalent), and gadolinium chloride (GdCl3) solutions.
  8. Concentration Sweep: Stepwise dilution from 108 nM down to single-digit nM to establish calibration curves and limit of detection.
  • Applicable Materials: This research relies on nitrogen-vacancy (NV) ensemble nanodiamonds in the 40-120 nm size window with high NV density. At 6CCVD, we engineer Optical-Grade Single Crystal Diamond (SCD) and Polycrystalline Diamond (PCD) wafers with controlled nitrogen concentration during MPCVD growth, providing the bulk feedstock from which NV-active nanodiamonds are milled or detonation-sourced. For sensing applications demanding dense NV ensembles, our as-grown SCD plates (0.1 µm - 500 µm thickness) deliver the crystal quality required for long coherence times and reproducible T1 behavior.

  • Customization Potential: The 532 nm excitation wavelength and ~150 µs optimal dark time in this paper both require probes with tightly controlled NV density and minimal surface graphitic noise. 6CCVD offers custom metalization (Ti, Pt, Au, Pd, W, Cu) for hybrid device integration—useful when researchers transition from solution-phase nanodiamond relaxometry to chip-based or fiber-coupled NV sensing platforms. Our laser cutting and dicing services support custom geometries for microfluidic cells or in-flow reaction chambers.

  • Engineering Support: The unexpected finding that smaller nanodiamonds exhibited higher T1 times suggests that NV ensemble density and particle geometry are more critical than previously assumed. 6CCVD’s in-house PhD engineering team can assist with material selection for quantum sensing, bio-MRI relaxometry, and NV-magnetometry projects, advising on nitrogen doping levels, post-growth irradiation/annealing protocols, and surface functionalization strategies to extend this research toward intracellular measurements.

  • Call to Action: For custom specifications, NV-grade diamond consultation, or material selection for your quantum sensing or bio-detection platform, visit 6ccvd.com or contact our engineering team directly.

View Original Abstract

Diamond magnetometry is a quantum sensing method involving detection of magnetic resonances with nanoscale resolution. For instance, T1 relaxation measurements, inspired by equivalent concepts in magnetic resonance imaging (MRI), provide a signal that is equivalent to T1 in conventional MRI but in a nanoscale environment. We use nanodiamonds (between 40 and 120 nm) containing ensembles of specific defects called nitrogen vacancy (NV) centers. To perform a T1 relaxation measurement, we pump the NV center in the ground state (using a laser at 532 nm) and observe how long the NV center can remain in this state. Here, we use this method to provide real-time measurements of free radicals when they are generated in a chemical reaction. Specifically, we focus on the photolysis of H<sub>2</sub>O<sub>2</sub> as well as the so-called Haber-Weiss reaction. Both of these processes are important reactions in biological environments. Unlike other fluorescent probes, diamonds are able to determine spin noise from different species in real time. We also investigate different diamond probes and their ability to sense gadolinium spin labels. Although this study was performed in a clean environment, we take into account the effects of salts and proteins that are present in a biological environment. We conduct our experiments with nanodiamonds, which are compatible with intracellular measurements. We perform measurements between 0 and 10<sup>8</sup> nM, and we are able to reach detection limits down to the nanomolar range and typically find T1 times of a few 100 μs. This is an important step toward label-free nano-MRI signal quantification in biological environments.