Skip to content

Quantum-enabled electrochemical sensing of redox-driven nitrogen-vacancy charge state dynamics

MetadataDetails
Publication Date2025-09-24
JournalAcademia quantum.
AuthorsShalini Menon, Ashley J. Tyler, Melissa L. Mather
InstitutionsInstitute of Physics, University of Nottingham
AnalysisFull AI Review Included

Quantum-Enabled Electrochemical Sensing of Redox-Driven NV Charge State Dynamics: Technical Documentation & Material Strategy

Section titled “Quantum-Enabled Electrochemical Sensing of Redox-Driven NV Charge State Dynamics: Technical Documentation & Material Strategy”
  • Innovation: Integration of disposable Indium Tin Oxide (ITO) screen-printed electrodes (SPEs) with inverted fluorescence microscopy to enable real-time, simultaneous electrochemical and optical readout of fluorescent nanodiamonds (fNDs).
  • Core Mechanism: Modulation of NV− and NV0 charge state photoluminescence (PL) intensity via applied electrochemical potentials (cyclic voltammetry and amperometry).
  • Biological Validation: Reversed PL response observed upon interaction with Cytochrome C (Cyt-c), indicating direct electron exchange between the redox protein and the NV quantum system.
  • Matrix Compatibility: Demonstrated functionality in complex biological matrices (Human Serum), with successful Cyt-c detection at both 5-fold and 2-fold dilutions.
  • Targeted Applications: Label-free biosensing, redox biology research, voltage imaging, and diagnostic platforms for oxidative-stress-related diseases.
  • Required Material Format: Sub-200 nm hydrogenated (H-fND) and carboxylated (COOH-fND) single-crystal diamond particles with controlled NV density (2-3 ppm).
  • Significance: Establishes a practical pathway for translating solid-state quantum sensing into standard biological laboratory workflows.
ParameterValueUnitContext / Notes
Working Electrode MaterialIndium Tin Oxide (ITO)—Optically transparent for simultaneous PL monitoring
Working Electrode Diameter4mmDrop-cast area for fND deposition
fND Nominal Diameter100nmSource: Adámas Nanotechnologies
fND Stock Concentration1mg/mLAqueous suspension
fND Working Concentration0.2mg/mLDiluted in ultra-purified water
Drop-cast Volume2.5µLDeposited onto 4 mm ITO working electrode
NV Content (H-fND)2-3ppmHydrogen-terminated surface chemistry
NV Content (COOH-fND)~3ppmCarboxylated surface chemistry
Microscope TypeOlympus IX83—Inverted fluorescence configuration
Objective Lens20x UPLSAPO—NA = 0.75
Camera TypePhotometrics Prime 95B sCMOS—30 ms exposure time
Excitation (NV0)470nm30 nm bandwidth bandpass filter
Excitation (NV−)515-532nm550 nm channel, 545 nm/30 nm bandpass
Emission (NV0)575 (ZPL); 580-600 (peak)nm550 nm/40 nm bandpass emission filter
Emission (NV−)637 (ZPL); up to ~800nm640 nm/40 nm bandpass emission filter
Dual-State Emission Filter575nmLongpass for combined NV0/NV− PL
PotentiostatDropsens µstat200 Bipotentiostat—Cyclic voltammetry & amperometry modes
Reference ElectrodeSilver (Ag)—Integrated into SPE
Auxiliary ElectrodeCarbon—Integrated into SPE
Test MatricesPBS, Cyt-c solution, Human Serum—Serum tested at 5-fold and 2-fold dilutions
  1. Electrode Preparation

    • Clean ITO screen-printed electrodes (4 mm working area).
    • Dilute fND stock suspension (1 mg/mL) to 0.2 mg/mL with ultra-purified water.
    • Drop-cast 2.5 µL onto the ITO working electrode.
    • Dry overnight at room temperature in a dust-free environment.
    • Use a fresh SPE for each measurement to prevent carryover artifacts.
  2. Optical Setup

    • Mount fND-modified ITO SPE on an Olympus IX83 inverted microscope stage.
    • Illuminate via CoolLED pE-4000 widefield source through a 20x/0.75 NA objective.
    • Selectively probe charge states using dedicated excitation/emission filter sets (470 nm for NV0; 545-550 nm for NV−).
    • Capture PL with a Photometrics Prime 95B sCMOS camera (30 ms exposure).
  3. Electrochemical Control

    • Connect SPE to a Dropsens µstat200 bipotentiostat.
    • Apply potential windows via cyclic voltammetry (CV) to map NV charge-state-dependent PL modulation.
    • Hold potentials using amperometry to monitor time-dependent PL responses.
  4. Redox Interaction Assay

    • Introduce Cytochrome C at physiologically relevant concentrations.
    • Monitor PL response reversal as evidence of electron exchange between Cyt-c and NV centers.
    • Validate in Human Serum at 5-fold and 2-fold dilutions to confirm matrix tolerance.
  5. Surface Chemistry Strategy

    • Compare hydrogen-terminated (H-fND) vs. carboxylated (COOH-fND) particles to isolate surface-charge effects on NV electrochemistry.
6CCVD Material GradeRelevance to This Research
Optical Grade Single Crystal Diamond (SCD)Suitable source material for producing high-purity fluorescent nanodiamonds (fNDs) with controlled NV center density (2-3 ppm range).
Nitrogen-Doped SCD WafersUsed as feedstock for HPHT milling or CVD overgrowth to generate NV-rich nanodiamond suspensions with reproducible optical properties.
Boron-Doped Diamond (BDD)Relevant for advanced variants where conductive diamond substrates could replace ITO for all-diamond electrochemical quantum sensors.
Polycrystalline Diamond (PCD) PlatesOptional substrate for integration into next-generation, fully diamond-based sensing chips.
  • Nanodiamond Sizing: 6CCVD can produce and post-process diamond particles down to sub-100 nm ranges with narrow size distributions, critical for consistent electrode drop-casting and uniform PL signal.
  • Surface Functionalization: Custom hydrogenation (H-terminated) and carboxylation (COOH-terminated) chemistries are available to match the two surface conditions benchmarked in this study.
  • NV Density Tuning: NV content (ppm-level) can be specified during MPCVD growth to ensure batch-to-batch reproducibility for quantitative biosensing.
  • Custom Electrode Geometries: Laser-cutting and metallization services (Ti/Au, Ti/Pt/Au, Cr/Au, etc.) allow integration of diamond elements directly onto bespoke SPE architectures beyond standard 4 mm ITO formats.
  • Wafer Formats: For researchers scaling from suspension-based fNDs to bulk diamond sensing elements, SCD and PCD substrates up to 125 mm are available, polished to Ra < 1 nm (SCD) or < 5 nm (inch-size PCD).
  • 6CCVD’s in-house PhD engineering team can assist with:
    • Selecting the appropriate diamond grade (SCD vs. PCD, intrinsic vs. doped) for quantum-electrochemical sensing platforms.
    • Optimizing NV concentration and surface termination protocols to maximize charge-state PL contrast.
    • Designing integrated diamond-on-electrode architectures for next-generation quantum biosensors targeting redox biomarkers (Cyt-c, ROS, and disease-related oxidative stress markers).
    • Specifying metallization stacks (Au, Pt, Pd, Ti, W, Cu) for hybrid quantum-electrochemical device fabrication.

For custom specifications, NV-tuned nanodiamond consultations, or metallization design for your quantum biosensing platform, visit 6ccvd.com or contact our engineering team directly.

View Original Abstract

Redox signaling, fundamental to cellular processes and implicated in disease, involves dynamic electron transfer events that are challenging to probe within complex biological environments. This study introduces an innovative quantum sensing platform for biological electrochemistry. We demonstrate its capacity for real-time investigation of the redox-driven nitrogen-vacancy (NV) center charge state dynamics in fluorescent nanodiamonds (fNDs). The platform integrates disposable indium tin oxide screen-printed electrodes with inverted light microscopy, enabling simultaneous electrochemical control (cyclic voltammetry and amperometry) and optical monitoring of fND photoluminescence (PL). We show that varying electrochemical potentials directly modulate fND PL intensity, reflecting NV charge state transitions, and that interaction with the well-characterized electron-transferring protein, Cytochrome C (Cyt-c), results in a reversed PL response, indicating electron exchange. Importantly, the platform’s functionality in human serum (HS) is demonstrated through Cyt-c detection at both 5-fold and 2-fold dilutions, illustrating the performance achievable in the presence of a biological matrix. Overall, this simple quantum sensing approach, integrating electrochemical control and optical monitoring on a disposable, microscopy-compatible platform, offers a significant advance for probing biological redox processes, with the potential to enable future spatially resolved studies of cellular signaling and to inform new diagnostic strategies.

  1. 2024 - Fundamentals of redox regulation in biology [Crossref]
  2. 2025 - Redox regulation: mechanisms, biology and therapeutic targets in diseases [Crossref]
  3. 2024 - Navigating the landscape of optical biosensors [Crossref]
  4. 2023 - Hemoglobin and cytochrome c. reinterpreting the origins of oxygenation and oxidation in erythrocytes and in vivo cancer lung cells [Crossref]
  5. 2025 - Electrochemical sensor for biological samples monitoring [Crossref]
  6. 2024 - Electrochemical protein biosensors for disease marker detection: progress and opportunities [Crossref]
  7. 2025 - Recent advances in electrochemical biosensors for neurodegenerative disease biomarkers [Crossref]
  8. 2020 - Molecular and supramolecular multiredox systems [Crossref]
  9. 2023 - Nitrogen vacancy defects in single-particle nanodiamonds sense paramagnetic transition metal spin noise from nanoparticles on a transmission electron microscopy grid [Crossref]
  10. 2023 - Nanoscale quantum sensing with nitrogen-vacancy centers in nanodiamonds—a magnetic resonance perspective [Crossref]