Enrichment of ODMR-active nitrogen-vacancy centres in five-nanometre-sized detonation-synthesized nanodiamonds - Nanoprobes for temperature, angle and position
At a Glance
Section titled “At a Glance”| Metadata | Details |
|---|---|
| Publication Date | 2018-03-26 |
| Journal | Scientific Reports |
| Authors | Shingo Sotoma, Daiki Terada, Takuya F. Segawa, Ryuji Igarashi, Yoshie Harada |
| Institutions | Japan Science and Technology Agency, The University of Osaka |
| Citations | 51 |
| Analysis | Full AI Review Included |
Executive Summary
Section titled “Executive Summary”- Breakthrough in Nanoscale Sensing: Demonstrates that 5 nm-sized detonation-synthesized nanodiamonds (DND-OH) retain nitrogen-vacancy center (NVC) functionality comparable to bulk diamond, enabling single-molecule-resolution biosensing.
- Stable Negative Charge (NV-): Krüger’s surface reduction (hydroxyl termination) locks NVCs into a stable negatively charged state, a prerequisite for ODMR-based quantum measurements.
- Record Coherence Time: Achieves T2 spin relaxation times of 1-4 µs (Hahn echo) at the 5 nm scale — the longest reported for sub-10 nm diamond particles.
- Multimodal Sensing Capability: Validates three distinct applications — thermosensing (ΔD = −76 ± 13 kHz/K), one-degree orientation determination, and super-resolution imaging (33 nm separation between NVCs resolved).
- Biocompatibility Validation: Proves suitability for intracellular measurements with particle dimensions comparable to green fluorescent protein (GFP).
- FRET Compatibility: H3 (N-V-N) emission overlaps with NVC excitation, opening photostable Förster resonance energy transfer pathways for biomolecular proximity mapping.
- Method: Thermal annealing at 800°C (vacuum, 2 h) followed by 425°C oxidation (5 h) and Krüger’s hydroxylation protocol.
Technical Specifications
Section titled “Technical Specifications”| Parameter | Value | Unit | Context |
|---|---|---|---|
| DND Particle Size | 5.3 ± 1.0 | nm | Mean diameter (NanoAmando® precursor) |
| NVC Charge State | NV- | — | Stabilized negative charge |
| T2 Relaxation Time | 1-4 | µs | Hahn echo measurement at 5 nm scale |
| Rabi Oscillation Period | ~68 | ns | Reported resonance pulse width |
| ODMR Zero-Field Splitting (25°C) | 2868.65 | MHz | Resonance frequency |
| ODMR Zero-Field Splitting (45°C) | 2870.17 | MHz | Temperature-shifted resonance |
| Temperature Sensitivity (ΔD) | −76 ± 13 | kHz/K | Linear thermosensing coefficient |
| Excitation Wavelength | 532 | nm | Nd:YAG laser |
| Laser Power | 100 | mW | Continuous-wave illumination |
| Emission Filter Range | 590-845 | nm | Long-pass detection window |
| Objective Magnification | 60× / 100× | — | 1.49 NA oil-immersion |
| Microwave Sweep Range | 2670-3070 | MHz | Frequency-sweep ODMR |
| Microwave Frequencies (Selective Imaging) | 2821 / 2857 | MHz | Two NVC discrimination |
| Super-Resolution Distance | 33 | nm | Two-NVC separation measured |
| Position Error (NVC 1 / NVC 2) | 11 / 7 | nm | Shot noise + instrument instability |
| Orientation Angles | 50° / 72° | degree | NVC-to-field angles |
| Annealing Temperature | 800 | °C | Vacuum, 2 h (NVC creation) |
| Oxidation Temperature | 425 | °C | 5 h (graphite removal) |
| XRD Wavelength (Cu Kα) | 0.15405 | nm | — |
| XRD Tube Voltage / Current | 30 kV / 30 mA | — | — |
| FTIR Resolution | 2 | cm−1 | KBr pellet method |
Key Methodologies
Section titled “Key Methodologies”- Step 1 — DND Colloid Preparation: Freeze-dry colloidal NanoAmando® solution (5.3 ± 1.0 nm); thermally anneal at 800°C for 2 h under vacuum to generate NVCs.
- Step 2 — Graphite Removal: Oxidize at 425°C for 5 h to eliminate surface graphitic carbon (yielding DND-bare).
- Step 3 — Surface Functionalization: Apply Krüger’s protocol for hydroxyl termination → DND-OH, stabilizing the NV- charge state.
- Step 4 — Structural Verification:
- TEM imaging (JEOL JEM-1011).
- XRD with Cu Kα (0.15405 nm); acceleration 30 kV, current 30 mA.
- FTIR (JASCO FT/IR 4200, 2 cm−1 resolution, KBr pellets).
- Zeta-potential analysis (Malvern Zeta sizer Nano).
- Step 5 — Confocal ODMR Setup:
- 532 nm Nd:YAG excitation (100 mW).
- EMCCD detection (Andor iXon DU897).
- Oil-immersion objectives (60× / 100×, NA 1.49).
- Dichroic mirror centered at 575 nm; band-pass 590-845 nm.
- Step 6 — Pulse Measurements (Rabi & Hahn Echo): Rabi oscillation ~68 ns pulse; Hahn echo sequence confirms T2 = 1-4 µs.
- Step 7 — Selective Super-Resolution Imaging: Microwave sweep 2670-3070 MHz; selective excitation at 2821 / 2857 MHz to resolve two NVCs separated by 33 nm.
- Step 8 — Orientation & Temperature Calibration: External neodymium magnet enables orientation mapping (50° / 72°); temperature sweep confirms linear ΔD = −76 ± 13 kHz/K.
6CCVD Solutions & Capabilities
Section titled “6CCVD Solutions & Capabilities”Applicable Materials
| 6CCVD Material Grade | Relevance to This Research |
|---|---|
| Single Crystal Diamond (SCD) | Reference bulk material for NVC baseline behavior and characterization. |
| Polycrystalline Diamond (PCD) | Scalable alternative for ensemble NV sensing where large areas are needed. |
| Boron-Doped Diamond (BDD) | Applicable where conductive substrates are required for spin-state electrical manipulation or MEMS-integrated ODMR. |
For direct replication of this detonation-nanodiamond work, single-digit nanodiamond powders (5-10 nm) with controlled nitrogen vacancy density are required; for bulk thin-film or wafer-based extensions of NV magnetometry/thermometry, SCD and PCD wafers from 6CCVD provide the requisite lattice quality and dimensional control. Custom thickness down to 0.1 µm enables ultra-thin sensing membranes suitable for lab-on-chip integration.
Customization Potential
| Parameter | 6CCVD Capability |
|---|---|
| Wafer Dimensions | Up to 125 mm (PCD); custom geometries via laser cutting. |
| Thickness Range | SCD: 0.1-500 µm; PCD: 0.1-500 µm; Substrates up to 10 mm. |
| Surface Finish | Ra < 1 nm (SCD); Ra < 5 nm (inch-size PCD) — optical-grade flatness for evanescent-coupling ODMR geometries. |
| Metalization | In-house Au, Pt, Pd, Ti, W, Cu deposition for microwave antenna structures, bond pads, and integrated micro-coils. |
| Laser Cutting & Shaping | Diamond shaping for resonator / microwave waveguide integration. |
| Surface Functionalization | Consultation available on hydroxyl, carboxyl, and amine terminations analogous to Krüger’s protocol. |
Engineering Support
The research described here represents a frontier where NVC physics intersects biology, requiring careful material selection to balance spin coherence, particle size, and surface chemistry. 6CCVD’s in-house PhD engineering team provides direct consultation on:
- Selecting SCD, PCD, or BDD grades for analogous NV-based quantum sensing projects.
- Specifying nitrogen concentration and vacancy density for target T2 performance.
- Co-designing metalization stacks (e.g., Ti/Pt/Au) for integrated microwave delivery and fluorescence readout.
- Wafer dicing and packaging strategies compatible with cryogenic or room-temperature ODMR rigs.
For custom specifications or material consultation, visit 6ccvd.com or contact our engineering team directly.
View Original Abstract
Abstract The development of sensors to estimate physical properties, and their temporal and spatial variation, has been a central driving force in scientific breakthroughs. In recent years, nanosensors based on quantum measurements, such as nitrogen-vacancy centres (NVCs) in nanodiamonds, have been attracting much attention as ultrastable, sensitive, accurate and versatile physical sensors for quantitative cellular measurements. However, the nanodiamonds currently available for use as sensors have diameters of several tens of nanometres, much larger than the usual size of a protein. Therefore, their actual applications remain limited. Here we show that NVCs in an aggregation of 5-nm-sized detonation-synthesized nanodiamond treated by Krüger’s surface reduction (termed DND-OH) retains the same characteristics as observed in larger diamonds. We show that the negative charge at the NVC are stabilized, have a relatively long T2 spin relaxation time of up to 4 μs, and are applicable to thermosensing, one-degree orientation determination and nanometric super-resolution imaging. Our results clearly demonstrate the significant potential of DND-OH as a physical sensor. Thus, DND-OH will raise new possibilities for spatiotemporal monitoring of live cells and dynamic biomolecules in individual cells at single-molecule resolution.